WARNING! Incorrect operation and incorrectly performed work can cause serious personal injury or material damage. The Fronius Smart meters may only be installed and commissioned by trained personnel and only within the scope of the technical regulations. Before working with the device, read and understand all enclosed, printed, and online documents! This document does not describe all of the possible system configurations.

SOFTWARE REQUIREMENTS

Fronius Datamanager 2.0| ≥ 3.16.1 version
Fronius Symo Hybrid| ≥ 1.16.1 version
MEASURING INPUT
Nominal voltage (4-conductor) range| 208 – 400 V (±20%)
Power consumption in the voltage path (max. voltage)| ≤ 10 VA
Nominal frequency
Tolerance| 50 – 60 Hz
45 – 65 Hz
Nominal current, lb| 5 A
Maximum current, Imax| 65 A
Starting current| 20 mA
Short-time overload (EN IEC 62053-21, EN IEC 62053-23)| 30 lmax / 0.001 s
Self-consumption – current path (max. current)| ≤ 1 W
Power factor
Operating range
(EN IEC 62053-21, EN IEC 62053-23)| active cosφ 0.5 ind – 0.8 cap,
reactive sinφ 0.5 ind – 0.5 cap
Current distortion factor| in acc. with EN 50470
OUTPUT
RS485 communication (Electrically isolated from measuring input)
Standard| RS485 – 3 conductors
Protocol| Compatible with Modbus RTU
Addresses| 1 – 255
Baud rate| 300, 2400, 9600 bit/s
Response time| ≤ 200 ms
INSULATION (EN IEC 62052-11, EN IEC 62053-21)
Installation category| III
Degree of pollution| 2
Insulation voltage| 4 kVAC RMS (1 min)
ELECTROMAGNETIC COMPATIBILITY
Emission test| In acc. with EN IEC 62052-11, EN 50470-3
Immunity test| In acc. with EN IEC 62052-11, EN 50470-3
OPERATING CONDITIONS
Reference temperature| 25 °C (± 5 °C)
Operating range| -25 to +55 °C
Temperature limit for storage and transport| -30 to +80 °C
Mechanical environment
Electromechanical environment| M2
E2
HOUSING
Housing| 3 modules according to DIN 43880
Sealable housing/terminal cover|
Connection| Screw connection
Mounting| Can be snapped onto 35 mm DIN rail
Housing material| Noryl, self-extinguishing
Degree of protection (EN 60529)| IP51 housing, IP20 connections
Weight| 240 grams
TERMINALS – MEASURING INPUT
Wire| min. 1 mm² / max. 16 mm²
Recommended torque| max. 2.8 Nm
TERMINALS – DATA OUTPUT (N-CONNECTOR)
Wire| min 0.05 mm²
Recommended torque| max. 0.4 Nm

Detailed, country-specific warranty terms are available on: www.fronius.com/solar/warranty

FIND MORE INFORMATION
manuals.fronius.com/html/4204260349

https://manuals.fronius.com/html/4204260349/en.html
42,0410,2496 006-22042021

FRONIUS INTERNATIONAL GMBH

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals