NEXA WSA-102 Optical Smoke Alarm for Wireless Connection in Series User Guide
- October 27, 2023
- NEXA
Table of Contents
Model: WSA-102
OPTICAL SMOKE ALARM FOR
WIRELESS CONNECTION IN SERIES
This instruction leaflet contains important information on how to properly
install and maintain the smoke alarm. Read this entire folder before
installation and keep the folder for future reference.
Nexa’s fire alarm WSA-102 is designed to detect smoke particles and gives an
early warning if a fire should occur, (provided proper placement and
maintenance).
Main features:
- High sensitivity and stability
- Test and pause function
- LED indication shows normal function
- Low battery signal
- Can be connected in series with up to 6 smoke alarms
TEKNISK DATA
Strömkälla | DC 2 x 1.5V AA batteri |
---|
Batterityp: Gold Peak Group: GP 15A LR6 or Energizer: E91
Radiofrekvens| MHz
Räckvidd, fri sikt| upp till 20 m
Larmsignal| 85 dB (A) vid 3 meter
Driftstemperatur| 5 °C – 45°C
Luftfuktighet| 10 – 90 %
IMPORTANT
- The radio range may vary depending on the location, the design of the building and the materials used in the building.
- Do not remove or disconnect the batteries to stop false alarms as this will disable the vital function of the smoke alarm. Open windows or ventilate the air around the smoke alarm in order to stop it, and/or press the pause button.
- The smoke alarm is intended for use for use in singlefamily homes. In multiple-occupancy buildings, each home must be equipped with its own smoke alarms.
- This smoke alarm is not suitable for use in buildings that are not used for residential purposes. The smoke alarm is no substitute for a full alarm system that is required by law or by the fire authorities.
- The smoke alarm detects combustion particles in the air (smoke). It does not react to flames or gas. The smoke alarm is designed to emit an alarm signal if a fire is developing.
- The smoke alarm should be tested every week and replaced every ten years.
POSITIONING THE SMOKE ALARM
For the smoke alarm to provide an early warning, it has to be installed in the
location where the fire starts. Therefore, Nexa recommends that you install
smoke alarms in each room and on all floors.
Single-level home: To achieve minimum protection, position the alarm in
the entrance hall between the living areas (including the kitchen) and the
sleeping areas.
Position it as close as possible to the living areas, and make sure the alarm
can be heard by anyone in the bedrooms. See Figure 1, for example:
Multi-storey home: To achieve minimum protection, position and alarm in
the stairwell (at ground level) and another alarm above the landing on the top
floor, as well as an alarm on the ceiling in the basement at the foot of the
stairs. This covers the basement level, but not crawl spaces and unfurnished
attics. See the example in Figure 2.
Ceiling Installation
Hot smoke rises and spreads, so installing your smoke alarm in a central
location on the ceiling is recommended. Avoid areas where air does not
circulate, e.g. corners. Also keep it away from objects that may prevent the
free flow of air. Position the device at least 30 cm from light fittings or
interior fittings that may prevent smoke/heat reaching the detector. Position
it at least 1 metre away from the wall. See Figure 3A.
Wall mounting, if ceiling mounting is not possible Avoid installing the
device a long way into a corner.
Position the upper edge of the smoke alarm at least 15 cm and no more than 30
cm away from the ceiling. See Figure 3A.
Sloping ceilings
In the case of sloping surfaces or ceilings that move up towards a ridge, the
detector must be installed 90 cm from the highest point, measured
horizontally, because still air under the ridge may prevent smoke reaching the
device. See Figure 3B.
NOTE: There must be an alarm in every room (except the kitchen, bathroom and garage) to provide recommended/ maximum protection. DO NOT POSITION AN ALARM IN THE KITCHEN or BATHROOM as cooking smells or steam may activate the alarm. DO NOT POSITION AN ALARM IN THE GARAGE as there is a risk of it being triggered by exhaust fumes.
FIGURE 2. Multi-storey home
LOCATION ON CEILING AND WALL
PROGRAMMING
WSA-102 is equipped with radio transceivers for communication between units. Inorder for this to work, the smoke alarms must be linked togehter. Select one of the alarms as the master unit and mark it with an M on the back so that you recognize it, even at a later stage. During programming, the master unit listens for radio code from other alarms and connects the units into the system.
- Insert the batteries in the Master Unit, red LED indicator lights up after 3 seconds with sterady light. The unit is now in programming mode and ready to receive radio code from other alarms. (The master unit returns to normal mode around 30 seconds after pairing is complete or if no pairing was performed during the time period)
- Insert the batteries into the slave unit to be connected. After 2 seconds, the LED indicator flashes quickly on both devices for 3 seconds to confirm the pairing.
- Repeat step 2 with all slave units to be connected in the same system (max. 5).
- To end the programming, press the master unit’s test button once, the LED indicator goes out.
DELETE PROGRAMMING
- Remove the batteries from the smoke alarm
- Press and hold the test button, insert the batteries, release the button when the red LED indicator lights up
- Press the test button twice within 3 seconds, the smo alarm beeps briefly once to confirm deletion.
- After 5 seconds, the red LED indicator lights up, press the test button to exit.
TEST
Test the smoke alarm by pressing the test button for > 5 seconds. The smoke
alarm will respond by emitting alarm signal.
TEST INTECONNECTED
Test interconnected smoke alarms by pressing the test button on any smoke
alarm for> 10 seconds, connected smoke alarms will respond by emitting alarm
signal for 30 seconds, and then return to normal operation.
- Test your alarms both before and after installation so as to be sure that they are working.
- Only test your alarms using the test button. Never use a naked flame as this may destroy the smoke alarm.
- Get into the habit of testing your smoke alarms once a week.
NOTE: A number of factors can interfere with wireless communication.
You should therefore test smoke alarms every week to check that the
communication between the units is working properly.
INSTALLATION
- Remove the mounting plate on the back of the smoke alarm by rotating the mounting plate counterclockwise.
- Insert 2 x AA / LR6 batteries. Make sure you are using the correct polarity (+/-).
- Test and programme the smoke alarm – see the sections TESTING and PROGRAMMING.
- Install the mounting plate in a selected location on the ceiling. Take care when positioning your smoke alarm.
- Place the smoke alarm on the mounting plate and rotate the smoke alarm clockwise until it clicks into place.
- Press the test button to check that smoke alarm is working correctly.
OPERATION
During normal operation, the smoke alarm LED flashes every 40 seconds. This means that the battery and the device are working properly. If the detector detects smoke, it will emit a loud, pulsating alarm and the red LED will illuminate with a pulsating light until the smoke is gone.
STATUS | RED LED | ALARMSIGNAL |
---|---|---|
Normal | Flashes once every 40 seconds | None |
Low battery | Flashes once every 40 seconds | Short audible signal every 40 |
seconds
Fault notification| Flashes once every 40 seconds| Short audible signal
between LED flash
Pause mode| Flashes once every 40 seconds| None
PAUSE FUNCTION
The smoke alarm has a combined button for test and pause function.
The pause function temporarily switches off the smoke detection for 10 minutes
and can be activated if an alarm risks being triggered, or has been triggered,
due to cooking, steam or the like.
To activate the pause function, press the test / pause button for 5 seconds.
The alarm function will be stopped for 10 minutes, after which the smoke alarm
will be reset to normal sensitivity. If necessary, press the test / pause
button again to pause the alarm again.
Note that for other smoke alarms in an interconnected systems are not affected
by smoke detection.
REPLACE BATTERY
How often the battery needs to be replaced depends on the type of battery.
Feel free to change batteries routinely once a year, preferably on a specific
date.
- Turn the smoke alarm counterclockwise to remove from the mounting plate.
- Remove the old batterie Insert new batteries. Check the correct polarity +/-.
- Place the smoke alarm against the mounting plate and turn the smoke alarm clockwise until it clicks into place
- Press the test button to test the smoke alar
ALARM SIGNALS
WSA-102 emits various alarm signals. The alarm that detected smoke emits a
different signal than the others, which makes it possible to locate which unit
has triggered the alarm.
STATUS | Flashes | ALARMSIGNAL |
---|---|---|
The smoke alarm detects smoke | RED LED | Repeating: 3 x 0.5s Beeps Pause 1.5 s |
Device that receive signal from unit that have triggered alarms | No | |
indication | Repeating: 3 x 0.5s Beeps Pause 1.2 s | |
Test function | No indication | beeps Pause 1,5 s Then as above |
COMMON CAUSES AND HOW TO AVOID FALSE ALARMS
Smoke alarms detect and react to smoke particles in the air. These smoke
particles are what cause the smoke alarm to sound. This function means that
the smoke alarm may
also react to dust particles, moisture or other particles in the form of
pollen, insects, etc. These factors frequently cause false alarms.
FAULT SOURCE | REMEDY |
---|
Steam and moisture. A false alarm may be triggered if the smoke alarm is
positioned to close to a bathroom, laundry room or other areas where ambient
humidity is high.| Position the smoke alarm at least 2 metres away from the
bathroom, laundry room or other locations where ambient humidity may be high.
Dust and dirt. The smoke alarm will attract a certain amount of dust and
pollen particles as the air passes freely through the detection chamber. This
may lead to false alarms. The smoke alarm may also become more sensitive on
account of this, which may result in unwanted alarms.| Vacuum the smoke alarm
regularly, use a plastic nozzle so as not to damage the electronics. Avoid
installing smoke alarms in locations where there is a lot of dust and dirt.
Ideally, place a “hood” over the smoke alarm or remove it entirely while you
are carrying out renovations at home.
Draughts, dust and air flows. False alarms may be caused if the smoke alarm is
placed too close to doors, windows, ventilation systems, fans, air ducts, heat
pumps and suchlike. This may cause dust particles to fly up and into the
detection chamber.| Do not install smoke alarms in draughty locations or close
to windows or doors, ventilation, fans, air ducts, heat pumps and suchlike.
Find a better location for your smoke alarm, further away from draughts and
air flows.
Temperature variations may cause condensation in the detection chamber – if
the smoke alarm is placed in a room where windows are opened for ventilation
in winter, for example, or close to exits, balcony doors or other locations
where conditions switch between hot and cold.| Avoid installing smoke alarms
in rooms where the temperature changes rapidly or close to windows or doors
that are opened and closed frequently. Move the smoke alarm to a location
where the temperature is more consistent and stable.
Adverse location. Positioning the smoke alarm incorrectly in an unstable
indoor environment may lead to false alarms due to draughts, close proximity
to electrical devices (EMC) and lighting.| Position smoke alarms at least 5
metres away from fireplaces, stoves or other heaters. 2 metres away from
ventilation ducts, heat pumps and air conditioning.
1 metre away from lamps and fluorescent tubes.
SMOKE ALARM WARRANTY
This smoke alarm has a three-year limited warranty against anufacturing
faults. (Valid from the date of purchase.) The batteries are not covered by
the warranty. The warranty
liability is limited to the value of a corresponding smoke alarm. Defective
smoke alarms must be returned to the dealer together with a description of the
problem. Compensation of a new smoke alarm of the same or an equivalent type
will be given in the event of an approved complaint. A receipt confirming the
date of purchase must be shown when submitting a complaint.
MAINTENANCE AND CLEANING
The smoke alarm should be cleaned regularly, and at least twice a year. Clean
your smoke alarm by vacuuming externally along the opening to the optical
chamber to remove any dust or dirt.
IMPORTANT: Do not try to open the hatch to clean inside the smoke alarm
as this will invalidate your warranty.
RECYCLING
- The device mainly comprises materials that can be recycled.
- Do not dispose of the packaging, device and packaging contents with household waste without following applicable provisions.
- This product must be recycled according to EU Directive 2002/96/EC on waste from electrical and electronic equipment (WEEE).
- For more information, phone your dealer or the local authority responsible for waste disposal.
1008
NEXA 20220011
EN1460:2005/AC:2008
Tillverkare:
NEXA Trading AB, Sverige
webbplatswww.nexa.se