INCLUDED HARDWARE

Item Pièce Pieza| Description Description Descripción| Quantity Quantité Cantidad
---|---|---



| ****

Wall anchor Ancrage mural Anclaje mural

| ****


× 4



| ****

Retaining screw Vis de fixation Tornillo de fijación

| ****


× 4

|

Wire connector Capuchon de connexion Conector de cable

| ****


× 3



| ****

Junction box screw

Vis de boîtier de raccordement Tornillo de caja de conexiones

| ****


× 2



| ****

Light fixture Luminaire

Lámpara

| ****


× 1










ON OFF

TIMER

F

RESET             30 SEC







WARM                     COOL






PRESET DIMMER


20%       50%    100%



WARM  PRESET     COOL

COLOR



WHITE

| ****

Remote control Télécommande Control remoto

| ****


× 1

WARRANTY

Artika For Living Inc. is proud to offer you a fi ve-year (5) limited warranty on manufacturing defects from the date of purchase for residential use only. The warranty is extended to the original owner in USA, Canada, Mexico, UK, Iceland, France and Spain and is non-transferable. It does not apply to retailers, commercial applications or establishments. The original sales receipt is required for all warranty claims. The remedy under this limited warranty shall be product or part replacement at Artika’s discretion as provided herein and cannot exceed the original purchase price. This warranty is valid only on products installed in accordance with the building code and laws effective in the region where the unit is being used, as well as in accordance with the provided instruction manual. It does not cover products installed incorrectly or subjected to abnormal use. Product(s) or component part(s) may be required to be returned for inspection and verifi cation. Normal wear and tear, misuse, negligence, vandalism, improper maintenance (surface damage due to chemical interaction or cleaning agents including, but not limited to, scouring pads, use of cleaners containing abrasives, alcohol or other organic solvents) improper handling, accident, abuse,
fire, flood, theft, acts of God, neglect,
or alteration of the product will not be covered under this limited warranty. It excludes any accessories that accompany the product including, but not limited, to bulbs or batteries.
The warranty does not cover handling, labour, transportation, or any other cost associated with the installation or replacement of the product. This limited warranty is valid in the country of purchase and by Artika authorized retailers only. Artika for Living Inc. will not be held responsible for any direct or consequential damages or injuries related to the use of this product arising from improper use or installation of this product.
Please visit www.artika.com to discover more about Artika for Living Inc.

WHAT YOU WILL NEED

artika CL-ERR-HD2 LED Flush Mount Ceiling Light fig
8

WARNING:

Risk of electrical shock. Turn off the breaker at the panel.
Switch off the main electrical supply from the fuse box/circuit breaker before installing the unit or doing any maintenance.
Do not use outdoor.
IMPORTANT
The installer and/or user must read, understand and follow these instructions before installing the product. This product must be properly installed before it is used. If instructions are not followed, the manufacturer will not be held responsible for any problems or product malfunction. Failure to follow installation and/or operating instructions voids the warranty.
We recommend that this product be installed by a certifi ed electrician. In some states or provinces, it is a legal requirement for this type of product to be installed by a certifi ed electrician, according to the electrical and building codes effective in the region where the unit is used.

WARNING:
Changes or modifi cations to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device does not cause harmful interference, and
  2. this device must accept any interference received,including interference that may cause undesired operation.

NOTE: This equipment has been tested and found to comply with the limits for Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio or television reception. However, there is no guarantee that interference will not occur in a particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

Operation is subject to the following two conditions:

  1. this device does not cause interference, and
  2. this device must accept any interference received, including inteference that may cause undesired operation.

STEP-BY-STEP INSTALLATION

  • Turn off the power at the circuit breaker and the light switch. Ensure the power is off before removing the old light fi xture.
  • Install the mounting bracket on the junction box using the junction box screws (fi g. 1). Ensure that the two mounting bracket screws are pointing away from the ceilingartika CL-ERR-HD2 LED Flush Mount Ceiling Light fig 9
  • Place the canopy over the mounting bracket. Mark on the ceiling the 4 locations where the holes will be drilled. Remove canopy.
  • Drill pilot holes in the ceiling with a 1/4 in (6.5 mm) drill bit (fi g. 2).artika CL-ERR-HD2 LED Flush Mount Ceiling Light fig 10

REMOTE CONTROL FUNCTIONS

  1. Turn on and off light

  2. Reset light to 4000 K and maximum intensity

  3. Increases light intensity

  4. Decreases light color temperature

  5. Reduces light color
    temperature and intensity to the minimum

  6. 30 seconds timer off

  7. Increases light
    color temperature

  8. Decreases light intensity

  9. Quick adjustment of the light intensity

  10. Quick adjustment of the light colour temperatureartika CL-ERR-HD2 LED Flush Mount Ceiling Light fig 11

  • Connect the white wire (N) from the light fi xture to the white supply wire (N) from the junction box using a wire connector. Connect the black wire (L) from the light fixture to the black supply wire (L) from the junction box using a wire connector. Connect the ground wire (G) from the light fi xture to the ground wire (G) from the junction box using a wire connector (fi g. 3).
  • Push wall anchors into the holes.
  • Carefully push the wires into the junction box. Align the holes of the canopy from the light fi xture with the mounting braket screws.
  • Fasten the 4 retaining screws into the wall anchors (fi g. 4).artika CL-ERR-HD2 LED Flush Mount Ceiling Light fig 13
  • Carefully install the diffuser by lifting it into position (fi g. 5).
  • Rotate clockwise until it is fi xed (fi g. 5).
  • Restore electrical power.