Tenda TEG5328F L3 Managed Switch Installation Guide

June 4, 2024
Tenda

Tenda LOGO

Quick Installation Guide
L3 Managed Switch
TEG5328F

This quick installation guide instructs how to install, connect and log in to the device. For details, please download the user guide of the device.

Device installation

Installation notes
Follow the notes below to avoid device damages or personal injuries caused by misoperation.

  • Wear the ESD bracelet or gloves before installation and do not power on the switch before finishing the installation.
  • Use the included power cord to supply power to the switch.
  • Make sure that the input voltage matches the value of the switch specified in this guide.
  • Do not block any ventilation openings.
  • Do not remove the housing of the switch.
  • Keep the air in the ambient environment clean. Regularly perform dedusting.
  • Disconnect the switch from the power supply before cleaning it. Do not scrub the switch with any liquid. Clean only with a dry cloth.
  • Position the switch away from the power line, electric lamp, or power system.
  • Do not place any heavy things upon this switch.
  • If outdoor cabling is required, you are recommended to deploy a port lightning arrester (see the following figure for connection method) or AC power supply lightning arrester.

Tenda TEG5328F L3 Managed Switch - Device installation
1


Note:
There is a void sticker covering one of the screws on the housing of the switch. Do not remove the sticker without the permission of the local agent. Otherwise, you shall be responsible for any damage.
Installation tools

  • Desktop mounting: ESD bracelet (or gloves)
  • Rack mounting: ESD bracelet (or gloves), Phillips screwdriver, Screws

Tenda TEG5328F L3 Managed Switch - Device installation
2

Installation
Rack mounting
Step 1 Ensure that the subrack is stable and level, and properly grounded.
Step 2 Fix L-shaped brackets to the switch with screws. See the following figure.

Tenda TEG5328F L3 Managed Switch - Device installation
3

Step 3 Mount the switch at a proper height on the subrack and fix it to the rack with screws (self-prepared).

Desktop mounting
Paste the four footpad stickers to the corresponding four recesses on the bottom of the switch.
Then place the switch right-side up on a big enough, clean, stable, and flat desktop.

Tenda TEG5328F L3 Managed Switch - Device installation
4

Grounding
Step 1 Connect one side of the grounding cable to the grounding terminal of the switch.
Step 2 Connect the other side of the grounding cable to the grounding terminal of other grounded devices or a grounding bar in the equipment room.

Tenda TEG5328F L3 Managed Switch - Device installation
5| Tenda TEG5328F L3 Managed Switch - Device
installation 6

OR

---|---

Note:
Connect the grounding cable to the grounding system in the equipment room. Do not connect it to the fire main or lightning rod.

Physical connection

Refer to the following network topology to connect the switch to other network devices.

Tenda TEG5328F L3 Managed Switch - Physical Connection
1

LED indicators & button descriptions LED indicator Description
SYS Blinking: The system works properly.

Solid on: The system is not working properly.
Off: The system is starting up or not working properly.
Power| Solid on: The switch is powered on properly.
Off: The switch is not powered on, or not powered on properly.
Link/Act| Solid on: The corresponding port is connected, but no data is being transmitted over the port.
Blinking: Data is being transmitted over the corresponding port.
Off: The corresponding port is not connected or is not connected properly.
The green light indicates the port negotiation rate is 1000 Mbps. The orange light indicates the port negotiation rate is 10 Mbps or 100 Mbps.

Tips
All ports of this switch support the auto MDI/MDIX function, so both a straight cable and a crossover cable can be used to connect the switch to Ethernet devices.

Login

Step 1 Use an Ethernet cable to connect a computer to one of ports 1 to 24 of the switch.

Tenda TEG5328F L3 Managed Switch - LOGIN 1

Step 2 Set the IP address of the computer to an unused one in the same network segment as the switch.
For example, the default IP address of the switch is 192.168.0.1, set the IP address of the computer to 192.168.0.X (X ranges from 2 to 254 and is not occupied) and subnet mask to 255.255.255.0.

Tenda TEG5328F L3 Managed Switch - LOGIN 2

Step 3 Start a web browser (example: Chrome) on the computer, enter 192.168.0.1 in the address bar, and press Enter on the keyboard.

Tenda TEG5328F L3 Managed Switch - Physical Connection
3

Step 4 On the login page of the switch, enter the login user name and password (both are admin by default) and click Login.

Tenda TEG5328F L3 Managed Switch - LOGIN 3

Tips:
If the login window does not appear, refer to Q1 in Appendix A FAQ.
Login to the web UI of the switch succeeded. You can configure the switch now.

Appendix A FAQ

Tenda TEG5328F L3 Managed Switch - LOGIN 4

1. I cannot log in to the web UI of the switch. What should I do?****

– Try the following solutions:
– Check whether the switch is powered on properly.
– Check whether the computer is connected to the switch properly.
– Check whether the IP address of the computer is set to 192.168.0.X (X ranges from 2 to 254 and is not occupied).
– Clear the cache of the web browser or try another web browser.
– Disable the firewall of the computer, or try another computer.
– Check whether only one device with the IP address 192.168.0.1 exists in the local network.
– If the problem persists, reset the switch and try again.
– Reset method: When the Power LED indicator is solid on and the SYS LED indicator is blinking, hold down the Reset button for about 10 seconds, and release it when all LED indicators light up. The switch is restored to factory settings when the SYS LED indicator blinks again.

2. I forget the login user name and password when logging in to the web UI. What should I do?****

– Try entering the default login user name and password (both are admin). If failed still, reset the switch, and then use the default user name and password to log in.

3. How to deal with power system malfunctions?****

– You can determine whether the power system malfunctions by observing the Power LED indicator on the front panel of the switch. When the power system works properly, the Power LED indicator is solid on. If the Power LED indicator does not light up, perform the following operations:
– Check whether the switch is properly connected to a power source using the included power cord.
– Check whether the input voltage matches the value required by the switch.

4. How to connect to the switch through the Console port?****

– Follow the procedures below:
– Use the included console cable to connect a computer to the Console port of the switch.
– Run the connection software of the console port on the computer. Putty is taken as an example. Set the Connection type to Serial, Speed to 115200, and click Open on the lower right corner.
Tenda TEG5328F L3 Managed Switch - LOGIN 5
– Double press Enter on your keyboard and enter the user name and password (both are an admin by default) of the switch in the appeared window as shown below.

Appendix B Specifications

Port Number of 10/100/1000 Mbps RJ45 port 24
Number of 1000 Mbps SFP port 4 independent SFP ports
Console port 1

Baud rate: 115200
Performance| Exchange mode| Store-and-forward
MAC addresses table learning| Auto paging, auto-learning
MAC address table| 16 K
Dimensions (L xW x H)| 440 mm x 178.8 mm x 44 mm
Input power| AC 100 – 240V, 50/60Hz, 0.7A
Lightning protection| RJ45 port| Common mode: 6 kV
Power| Common mode:6 kV; Differential mode: 4 kV
Operating environment| Temperature: 0°C – 45°C
Humidity: (10% – 90%) RH non-condensing
Storage environment| Temperature: -40°C – 70°C
Humidity: (5% – 90%) RH non-condensing
Data transmission rate| Ethernet: 10 Mbps (half duplex)/20 Mbps (full duplex)
Fast Ethernet: 100 Mbps (half duplex)/ 200 Mbps (full duplex)
Gigabit Ethernet: 2000 Mbps (full duplex)
Transmission media| Ethernet: CAT3 UTP/STP or better
Fast Ethernet: CATS UTP/STP or better Gigabit Ethernet: CAT5e or CAT6 UTP/STP
Standard| IEEE 802.3, IEEE 802.3u, IEEE 802.3x, IEEE 802.3ab, IEEE 802.1d, IEEE 802.1 p,
IEEE 802.1 q, IEEE 802.1w, and IEEE 802.1s

Appendix C Safety and statement
CE Mark Warning
This is a Class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
The mains plug is used as a disconnect device, the disconnect device shall remain readily operable.
NOTE:

  1. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
  2. To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable.

RECYCLING
This product bears the selective sorting symbol for Waste electrical and electronic equipment (WEEE). This means that this product must be handled pursuant to European directive 2012/19/EU in order to be recycled or dismantled to minimize its impact on the environment.
User has the choice to give their product to a competent recycling organization or to the retailer when he buys new electrical or electronic equipment.
FCC Statement
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Caution! Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:

  1. The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment.
  2. To avoid unnecessary radiation interference, it is recommended to use a shielded RJ45 cable.

Technical support
Shenzhen Tenda Technology Co., Ltd.
6-8 Floor, Tower E3, NO.1001, Zhongshanyuan Road, Nanshan District, Shenzhen, China. 518052
USA hotline: 1-800-570-5892
Toll-Free: 7 x 24 hours
Canada hotline: 1-888-998-8966
Toll Free: Mon – Fri 9 am – 6 pm PST
Hong Kong hotline: 00852-81931998
Global Hotline: +86 755-2765 7180 (China Time Zone)
Website: www.tendacn.com
E-mail: support@tenda.com.cn
Copyright
©2020 Shenzhen Tenda Technology Co., Ltd. All rights reserved.
Tenda is a registered trademark legally held by Shenzhen Tenda Technology Co., Ltd. Other brand and product names mentioned herein are trademarks or registered trademarks of their respective holders.
Specifications are subject to change without notice.