Check that the unit has not been damaged during transport.
Read Manual, Cautions, and Warnings prior to operation of this equipment.
Protection Against Fire
Fire
- Maintain a minimum of 1-foot distance from any type of flame.
- For indoor use only. Do not expose the unit to rain or moisture.
- Do not install the unit too close to a heat source.
- Make sure cables are properly secured.
- Maximum surface operating temperature: 130º.
Protection Against Electrical Fire
Electrical
- Disconnect power before servicing.
- For connection to the main power supply, proceed to page 4.
- The power supply must be earthed (electronically grounded).
- This fixture must not be left on for long periods of time.
- This unit is for indoor use do not install outside.
Protection Against Mechanical Hazards
Mechanical
- Use a secondary safety chain when hanging the unit.
- Use quality clamps or bolts when positioning the unit.
- Do not open the unit while it is on. Risk of electrical shock.
What is Included
1pc Deco Drive CV3 Din
1pc User Manual
Specifications
Part Numbers
Fixture
5063 – Deco Driver CV3 Din
Mechanical Specifications
Housing: Black Plastic
Fastening System: DIN Rail-mount 35mm
Power Connection: 4 Pole Screw Terminal V-V+
DMX Connection: 3 Pole Screw Terminal in and out and RJ45 in and out
Output Connection: 5 Pole Screw Terminal and RJ45
Electrical Specifications
Input Voltage: 24V
Outputs: 3 Ports
Max Output Per Port: 96W
Sensor By-Pass: 12V
Software Up-loader: USB
Control & Programming
-
Protocol: DMX512 USITT Standard
-
Channel Modes: 5
1 Channel Mode: Dimmer
2 Channel Mode: Warm White, Cool White
3 Channel Mode: R, G, B
4 Channel Mode:R,G,B,W
7 Channel Mode: Dimmer, R,G, B,W, Strobe, Macro -
Control Modes: DMX 512 Auto: Pre-programs accessible via display Manual: Fixture intensity adjustable via Display settings
-
Software: Fixture Software up-loader via front USB
Main Power Connection
Caution!
- Do not connect the fixture to a dimmer system.
- This unit is to be connected to a 24V DC Output Power Supply.
- The power supply must be earthed (electronically grounded).
- Replace fuse only with the specified type and rating.
- The power supply must not be lower than 294W output.
The occupation of the connection cable is as follows:
This fixture requires a 294 Watt or greater 24V power supply (sold
separately).
Fixture requires a Minimum 14 Gage stranded wire from the power supply to the
Deco Driver CV3 24V DC Input when placed next to each other. Longer distances
will require higher cable gage.
Secondary input and outputs can be used to jump voltage to a secondary device
Cable Gage | DC – | DC+ |
---|---|---|
Min 14AWG | Black | Red |
DMX-512 Connection
The fixture is equipped with RJ45 and 3 Poll Screw Terminal for DMX signal input and output. The connections are wired in parallel. Only use a shielded twisted pair cable designed for RS-485 and Cat 6. RJ45 plugs and connectors are needed in order to connect the controller with the fixture or the fixture with another.
XLR Connections
Pin 1| Ground
Pin 2| Data –
Pin 3| Data +
Pin1| Data +
---|---
Pin 2| Data –
Pin 3| N/A
Pin 4| N/A
Pin 5| N/A
Pin 6| N/A
Pin 7| Ground
Pin 8| Ground
Caution! At the last fixture, the DMX signal needs to be terminated with
a terminator. Place a 120 Ohm resistor between the (-) and the (+) signal of
the plug on the last fixture. Pre-manufactured terminator plugs are available
for purchase from your MEGA-LITE dealer (P-DMXT).
12V Bypass Sensor
A bypass Sensor is used for connecting a 12V DC sensor. There are many
types of sensors that can be connected like Motion Sensors and Dusk to Dawn
Sensors. If a 12V DC Signal is detected it will cause all dimmer channels to
turn on to 100%.
Output Connection
The fixture is equipped with RJ45 and 5 Poll Screw Terminal for output to the
lights. Different Deco Lighting Fixtures are equipped with either Cat6A or 5
Conductor stranded cable. Please consult the lighting fixtures manual for what
type of cable your lighting fixture requires.
Cable Requirements
Cat6A: 23 gages or higher, maximum distance before voltage drop 100ft
Stranded: 5 conductor 20AWG or higher, maximum distance before voltage drop
100ft
Size and Weight
Fixture Size: | 6.25” X 2.32” X 4.12” |
---|---|
Fixture Weight: | .56lb |
Packaged Size: | 7” X 4” X 3” |
Packaged Weight: | 1.2lb |
Main Control Menu
The control board on the fixture is your interface to access and control all the functions on the unit. Its digital display gives you a code view of the options and functions. The following will explain each function and its options. There are also 2 LED indicators on the left side of the display. The first indicator is for power input notification, the second is for DMX signal notification.
DMX Address Press the E button to enter the Port menu. Use the E button to select desired Port Channel Mode and Start channel. Use the up/down keys to select.
Each Output Port has individual control and can have the same or different
Channel Mode or DMX Start Channel.
Auto Press the E button to enter the Auto Control menu. Use the E button
to select from 3 Chase programs
The program can be altered by selecting the Dimmer intensity from 0-255, and
Speed Control from 0-10. The program can be selected in the No section. (note:
Strobe program will require Manually selected dimmer on)
Static
Press the E button to enter the Static menu. Use the E button to select
desired preset color. Use the up/down keys to select.
The static function will let you select from 16 preset color combinations when
using 3 or 4 color fixtures. And adjust the intensity via the dimmer setting
in static color menu.
Manual Press E button to enter the Manual menu. Use the E button to
select desired manually adjusted color. Use the up/down keys to select.
The static function will let you select to adjust intensity output via display
For 4Ch or 7Ch Fixtures: use as discribed
For 3Ch Fixtures: White Dimmer Function will not be active
For 2Ch Fixture: Mirror the output value of Red & Green for Warm White and
mirror Blue and White for Cool White output
For 1Ch Fixtures all 4 outputs value must mirror the same output
Settings Press E button to enter the Static menu. Use the E button to
select desired preset color. Use the up/down keys to select.
New Firmware: Manufacture setting: Please contact Mega Lite for firmware
updates if needed.
Factory Reset: to return the fixture to the original factory settings enter
password 1234
Display Backlite: To leave the display screen on all the time set to ON. To
have the display turn off after 1 minute of no button interaction set to OFF
Display Lock: To leave the display screen on lock mode with no interface
access set to ON. To have the display keys have access set to OFF. (note) To
Unlock press and hold up and down at the same time for 4 seconds
Deco CV3 Din 1 Ch Mode| | |
---|---|---|---
DMX Ch| Function| Description| Value| Init
1| Dimmer| LED Intensity| 0-255| 255
| | | |
Deco CV3 Din 2 Ch Mode
DMX Ch| Function| Description| Value| ‘nit
1| LED Color| Warm White LED Intensity| 0-255| 255
2| LED Color| Cool White LED Intensity| 0-255| 255
| | | |
Deco CV3 Din 3 Ch Mode
DMX Ch| Function| Description| Value| Init
1| LED Color| Red LED Intensity| 0-255| 255
2| LED Color| Green LED Intensity| 0-255| 255
3| LED Color| Blue LED Intensity| 0-255| 255
| | | |
Deco CV3 Din 4 Ch Mode
DMX Ch| Function| Description| Value| Init
1| LED Color| Red LED Intensity (all outputs)| 0-255| 255
2| LED Color| Green LED Intensity (all outputs)| 0-255| 255
3| LED Color| Blue LED Intensity (all outputs)| 0-255| 255
4| LED Color| White LED Intensity (all outputs)| 0-255| 255
| | | |
Deco CV3 Din 7 Ch Mode
DMX Ch| Function| Description| Value| Init
1| Dimmer| Dimmer 0 to 100| 0-255| 255
2| LED Color| Red LED Intensity (all outputs)| 0-255| 255
3| LED Color| Green LED Intensity (all outputs)| 0-255| 255
4| LED Color| Blue LED Intensity (all outputs)| 0-255| 255
5| LED Color| White LED Intensity (all outputs)| 0-255| 255
6| Strobe| No Function| 0-1| 0
Strobe (slow to fast)| 2-127
Random Strobe (slow to fast)| 128-255
7| Macro| No Function| 0-1| 0
Color Fade (slow to fast)| 2-127
Color Chase (slow to fast)| 128-255
Rigging the Fixture
When rigging a unit, it is very important that you follow common safety
procedures. Rigging requires extensive experience including but not limited
to, calculating working loads, material being used, and periodic safety
inspections. If you lack these qualifications, do not attempt the installation
yourself. The installation location of the projector must be built to hold 10
times the weight for one hour without any damage. Installation should be
checked at least one time a year by a skilled person.
A fixture is designed to be installed with a 35mm Din rail track inside a NEMA
box.
Cleaning and Maintenance
Installation Maintenance. The operator has to make sure that the unit is
operating safely and has the installations and electronics checked by an
expert every 2 years.
The following points must be considered during the inspection: 1) All screws
used for installing the device or part of the device have to be tightly
connected and must not be corroded. 2) There must not be any deformations on
the housing, fixation, and installation spots (ceiling, suspension, trussing).
3) The electronic power supply cables must not show any damage, material
fatigue (e.g. porous cables), or sediments. Further instructions depending on
the installation spot and usage have to be adhered by a skilled installer and
any safety problems have to be removed.
Note: There are no serviceable parts inside the device. Maintenance and
service operations are to be carried out by authorized dealers.
Replacing the fuse: When possible, only replace the fuse with the same type
and rating.
Replacing the power cable: If the power cable of this device becomes damaged,
it has to be replaced by authorized dealers or trained professionals only.
Should you have further questions, please contact your dealer.
Parts List
5063PCBMAI | CV3 Display / Main |
---|---|
5063PCBDRI | CV3 Driver |
5063POW | Mean Well NDR-480-24 Power Supply |
506000N5SC | CV3 5 pole screw terminal |
5060C0N4SC | CV3 4 pole Screw terminal |
5060C0N3SC | CV3 3 pole screw tern innal |
506000N2SC | CV3 2 pole screw terminal |
General Terms & Conditions
- All resellers must have approved and signed Reseller Application on file, including their respective state tax information and W-9. Applications are re-evaluated on a fiscal calendar year basis to assure business integrity and tax status.
- Cash, check, cashiers, check, ACH, wire transfer, MasterCard, Visa, Discover, and American Express have accepted forms of payment.
- Past due invoices will be charged 1.5% per month finance charge. Uncollected invoices are subject to be turned over to collection.
- The reseller will pay all reasonable expenses incurred in the course of collections.
- The proper venue for litigation will be Bexar County, Texas.
- Returned checks will be charged a $50.00 fee.
- All prices are in U.S. Dollars.
- All prices and specifications are subject to change without notice, sales order confirmations are emailed and will reflect correct pricing.
- All terms are insured, monitored, analyzed, and approved by Coface USA. Changes in the credit lines and approved terms can change without notice. Company authorization of credit is based on Coface approvals. Any conflicts or disagreements should be referred to 650 College Rd East Suite 2005 Princeton, NJ 08540. 1-609-469-0400. E-mail: cofaceusa@coface.com
- Returns are subject to a 25% restocking charge plus any necessary charges for repair or re-packaging.
Shipping Terms & Conditions
- All orders are EXW San Antonio, TX (EXW means that a buyer/reseller incurs the risks for bringing the goods to their final destination) any deviation needs to be done in writing.
- UPS ground shipping is the preferred shipping method. Requests for specific carriers may require the use of the customer’s account number and may incur an additional charge for handling.
- Drop shipments are subject to all return charges at resellers’ expense. Drop shipments are not allowed outside of the territorial United States.
- NO C.O.D. shipments allowed.
- Returned and undelivered shipment charges are the buyer/reseller’s responsibility and will be billed to the buyer/reseller.
- The freight carrier and Company shipping@mega.lighing should be notified upon receipt of damaged freight, discrepancies, or non-conformities within 24 hours. The company can assist in making claims with carriers or agents in the event of any loss or damage.
- Upon acceptance in good order by Carrier from Company, the material becomes the property of the Reseller.
Warranty and Service Procedures
- All returns require an RMA# (Return Merchandise Authorization number) before returning goods for any reason. For service or warranty RMA, please email service@mega.lighting or call (210)684-2600. For sales or demo returns, please contact sales@mega.lighting.
- A case will be created and an RMA notice will be emailed. All units received must have the RMA # included with the unit as well as on the shipping label.
- All shipping charges are the responsibility of the customer: MEGA Systems, Inc., Service, 18668 HWY 16 N., Helotes, TX 78023
Warranty for Products Purchased Before 2021
Unless otherwise stated in writing, the product is covered by a one-year parts
and labor limited warranty and is subject to the same limitations listed under
the limited warranty exclusions listed below.
Warranty for Products Purchased After January 1, 2021
MEGA SYSTEMS INC (“MSI”) hereby warrants to the original purchaser/owner
(Customer”), MSI products to be free of manufacturing defects in material and
workmanship, for the warranty periods as defined below from the original
purchase invoice date. This warranty applies exclusively to new MSI branded
and/or distributed products listed below, purchased from an MSI AUTHORIZED
dealer/reseller. This warranty is not transferable and may or may not apply to
products sold and/or forwarded outside the United States. Please contact MSI
for applicable regional product warranty information.
The purchase of MSI products constitutes the Customer’s acceptance of all
warranty terms and conditions as listed in this limited warranty statement.
This warranty provides the Customer with legal rights, which may vary from
state to state. Please contact MSI regarding warranty questions prior to
purchasing.
Product / Series
Battery Powered LED
Moving LED, Hazers
Outdoor IP-Rated LED
Warranty Period | Coverage |
---|---|
Six-month battery, one year all other components | 1, 2 |
One Year | 2 |
Two Years | 3 |
Three Years | 4 |
House Light LED, Decorative LED, Compact LED, iCandy LED, Theatrical LED,
Strobe Wash LED, Follow Spot LED, Three YearsProduction & House of Worship
Control, Architectural Control, Theatrical Control, Dance Venue & Mobile DJ
Control, Direct View LED Displays and MV Controllers
1. Battery: 183 days/six months 2. Parts and Labor: 365 days/one year 3.
Parts and Labor: 730 days/two years 4. Parts and Labor: 1095 days/three years
This limited warranty excludes any defects caused by, resulting from, or
relating to the following:
Normal wear and tear of lamps, color media, brushes, contact rings, lamp
sockets, belts, and other parts prone to wear and tear. Misuse, abuse,
improper handling, accident, alteration or attempts to repair by or on behalf
of the owner or any person not authorized by MSI. Damage to the product
resulting from acts of God, including but not limited to, earthquakes,
hurricanes, tornadoes, lightning and other natural disasters, fire, explosion,
flood, riots, civil disorder, or any other cause beyond the reasonable control
of MSI. Exposure to harsh or excessively corrosive environmental conditions
(whether indoors or outdoors) including, but not limited to, extreme
temperature, humidity, atmospheric conditions (including salinity or
pressure), radiation (UV, infrared, or nuclear), shock, and conditions which
exceed the product’s Ingress Protection (“IP”) rating. Use of the product in a
manner which exceeds the applicable product specification, including, but not
limited to, exposure to excessive, insufficient, or other voltage conditions.
Installation or use of the product not in accordance with the technical
documentation, MSI guidelines (as may be posted on its website at
www.megasystemsinc.com from time to time or
otherwise designated by MSI or its brands) or applicable building and
electrical codes, regulations, and standards. Failure to maintain the product
in accordance with the technical documentation. Natural degradation and color
shift of the LED source over the course of normal product use. Slight
deviations in the specified values of intensity and color do not affect the
functionality of the product. Use of the product not for its intended purpose.
All warranty claims are evaluated under the terms of this limited warranty. If
a product fails within the warranty period and if, upon examination by MSI, it
is found to have failed for a covered cause, MSI will, at its sole discretion,
repair or replace the defective part or product or reimburse the purchaser a
pro-rated portion of the purchase price based on the percentage of the
warranty period still remaining as of the date that the returned product was
received by MSI. Should a replacement part or product be discontinued or
unavailable, MSI reserves the right, in its sole and absolute discretion, to
substitute a comparable replacement part or product for the defective part of
the product. MSI warranty obligation hereunder is limited solely to the repair
or replacement of or reimbursement for the particular parts or products
determined by MSI to have failed for a covered cause within the warranty
period. In no event shall MSI be responsible to replace or reimburse the
purchaser for any products or portions of a system that MSI determines has not
failed for a covered cause within the warranty period, even if such other
products or portions of a system are used together with products being
repaired or replaced by MSI under this warranty and the repaired product
differs in brightness, colors or any other attribute after the repair.
Costs of removal, shipping to MSI or its authorized representative and re-
installation are solely the responsibility of the purchaser. If MSI determines
that the product is covered by this limited warranty, it will only pay for
parts and labor as indicated by product type. If MSI determines that the
product is not covered by this limited warranty, the purchaser will have the
option of paying for the repair if the product can be repaired and the
purchaser shall be responsible for the cost of shipping the repaired product
back to the purchaser. MSI reserves the right, in its sole and absolute
discretion, to decline any repair.
IN NO EVENT SHALL MEGA SYSTEMS, INC. BE LIABLE FOR ANY INCIDENTAL,
CONSEQUENTIAL, SPECIAL, INDIRECT OR PUNITIVE LOSS OR DAMAGE OF ANY KIND,
INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS OR REVENUES, LOSS OF USE OF THE
PRODUCT OR ANY OTHER GOODS OR ASSOCIATED EQUIPMENT, DAMAGE TO ANY ASSOCIATED
EQUIPMENT, COST OF CAPITAL, COST OF SUBSTITUTE PRODUCTS, FACILITIES OR
SERVICES, DOWNTIME COST, INSTALLATION OR LABOR COSTS, OR CLAIMS OF THE
PURCHASER’S CUSTOMERS, WHETHER BASED ON WARRANTY, CONTRACT OR NEGLIGENCE,
ARISING IN CONNECTION WITH THE SALE, USE OR REPAIR OF THE PRODUCT. MEGA
SYSTEMS INC’S MAXIMUM LIABILITY SHALL NOT, IN ANY CASE, EXCEED THE PURCHASE
PRICE OF THE PRODUCT THAT GIVES RISE TO THE CLAIM.
EXCEPT FOR THE LIMITED WARRANTY SET FORTH HEREIN, ALL PRODUCTS SOLD BY MEGA
SYSTEMS, INC. ARE SOLD “AS IS” WITHOUT ANY WARRANTY, EXPRESS, OR IMPLIED,
STATUTORY OR OTHERWISE, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OR
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ALL OF WHICH ARE
EXPRESSLY AND SPECIFICALLY DISCLAIMED BY MEGA SYSTEMS, INC.
Customer Support
MEGA-Lite has a customer support line to provide set-up help and to answer any
questions should you encounter a problem. Please visit our website for any
other related technical documents. For service-related issues, please contact
our service dept.
Monday – Friday 9am to 6pm CST
(210)684-2600
service@mega.lighting
Manual Version
Please visit www. mega. lighting for the most up-
to-date manual version.
Manual Version 1.0
Date 10/28/2021
Fixture Software V1.1
Notes
MEGA-LITE
18668 Highway 16N Helotes,
TX 78023 Phone (210)684-2600
Fax (210)855-6279
www.mega.lighting
info@mega.lighting