MEGA LITE Framebot 600 LED Moving Head Framing Light User Manual

June 4, 2024
MEGA LITE

MEGA LITE Framebot 600 LED Moving Head Framing Light

Read Manual, Cautions, and Warnings Prior to operation of this equipment.

Protection Against Fire

  1. Maintain a minimum of 1 foot distance from any type of flame.
  2. For indoor use only. Do not expose unit to rain or moisture.
  3. Do not install the unit too close to a heat source.
  4. Make sure cables are properly secured.
  5. Maximum surface operating temperature: 130º.

Protection Against Electrical Fire

  1. Disconnect power before servicing. For connection to main power supply, proceed to page 4. The power supply must be earthed (electronically grounded). This fixture must not be left on for long periods of time.

Protection Against Mechanical Hazards

  1. Use secondary safety chain when hanging unit.
  2. Use quality clamps or bolts when positioning unit.
  3. Do not open unit while it is on. Risk of electrical shock.

What is Included

  • 1pc Framebot 600
  • 1pc Power Cable
  • 2pc Quick Release Clamp Mount
  • 1pc User Manual

Specifications

Part Numbers

  • Fixture
  • 1190 – Framebot 600

Mechanical Specifications

  • Housing: High Temperature Resistant Plastics
  • Fastening System: By Directional Quick Release Clamp Mount
  • Power Connection: Huashao power conn type (Nema 5-15 cable adapter included)
  • Signal Connection: 3 & 5 Pin XLR In and Out
  • Pan Movement: 540° (16 bit, 3 Phase stepper Motor)
  • Tilt Movement: 270° (16 bit, 3 Phase stepper motor)
  • Zoom Angle: 6.5° to 42° (16 bit)
  • Device Locking: Pan And Tilt Transportation Lock

Electrical Specifications

  • Light Source: 580W White LED
  • Color Temp WW: 6408K
  • CRI: (Warm White) 70
  • Color Flags: Cyan, Magenta, Yellow, Kelvin (CMYK)
  • Color Wheel: 6 Color, Bi direction
  • Rotating Gobo’s: 6 Indexing, Bi directional, Changeable Gobo’s
  • Static Gobo’s: 8 Fixed
  • Colormation: 1 continues rotation Colormation TM effect
  • Prism: 1 4 Facet Indexing Prism
  • Iris: 1 Linear adjustable Iris with Macro
  • Frost: 1 Frost Filter
  • Focus: Linear Focus (16 bit)
  • Strobe: 0.3-20 Per Second
  • Motorized Framing: 4 Blade, Dual Motor, Single Blade Blackout
  • Framing Rotation: 180° Indexing Rotation
  • RDM: Yes
  • Smart Cooling: Performance, Normal, Quiet Fan Modes
  • Display: 2.4” Color Display, Auto Flip
  • Power Supply: Electronic 100-240V AC 50/60
  • Power Consumption: 7.04 Amps / 807 Watts

Gobo’s

  • Rotating Gobo’s (Size 27.9mm, Image 22mm, Thickness Max 2.2mm)

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
fig-1

Static Gobo’s

Coloration

Colors

Color Mixing

Color Wheel

Main Power Connection

Caution

  • Do not connect fixture to a dimmer system.
  • This unit must be earthed. (Electronically grounded)
  • Replace fuse only with the specified type and rating. (F20AL250V)
  • This device is equipped with auto switching power supply that will allow the fixture to work from
    100V-240V AC 50/60Hz

DMX-512 Connection

The fixture is equipped with 3 and 5 pin XLR Sockets for DMX input and output connection. The sockets are wired in parallel. Only use a shielded twisted pair cable designed for RS-485 and 3 or 5 pin XLR plugs and connectors in order to connect the controller with the fixture or the fixture with another.

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
fig-7

Caution

On the last fixture the DMX signal needs to be terminated with a terminator. Pr-manufactured terminator are available for purchase from your Mega-Lite dealer item #P-DMX-T

Installation

Caution

  • The Installation must be carried out by an authorized dealer or trained professional.
  • Unit may cause severe injures, if you have doubts concerning the safety do not install.
  • Unit is to be 24 inches away from flammable materials.
  • Use high quality installation equipment to hang the unit.
  • Internal Fan Filters must be cleaned periodically as not to block airflow.

When rigging the it is very important that you follow common safety procedures. Rigging requires extensive experience including but not limited to calculating working weight loads, material being used and periodic safety inspections. If you lack these qualifications, do not attempt the installation yourself, instead use a professional  structural rigger. When rigging the unit always be secure with a secondary safety attachment. The installation location of the fixture has got to be built in the way that it can hold 10 times the weight for 1 hour with out any failures. Installation should be checked at least one time a year by a skilled professional.

Fixture should not be installed in location were temperature will reach 113°F or colder than 23°F

Cleaning and Maintenance

The following points must be considered during the inspection:

  1. All screws used for installing the device or part of the device have to be tightly connected and must not be corroded.

  2. There must not be any deformations on the housing, fixation and installation spots (ceiling, suspension, trussing).

  3. The electronic power supply cables must not show any damages, material fatigue (e.g. porous cables) or sediments. Further
    instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety problems have to be
    removed.

  4. Fixture housing must only be cleaned from the outside using only soap and water.

  5. Internal fan filters but be cleaned periodically

Note

  • Maintenance and service operations are to be carried out by authorized dealers.

Replacing the fuse

  • When possible, only replace the fuse with the same type and rating.

Replacing the power cable

  • If the power cable of this device becomes damaged, it has to be replaced by authorized dealers or
  • trained professionals only.

Should you have further questions, please contact your dealer.

Display Control

Main Control

The control board on the fixture base is your interface to access and control all the functions on the unit. It’s LCD display gives you a code view of the options and functions. The following will explain each function.

ADDRESS

Press Enter to view the fixture start. Press Enter again to make adjustment to the fixture address from 001 to 473 using the up/down buttons. Press Enter to confirm or Mode to go back. The fixtures start address will need to match the DMX Controllers assigned DMX start channel.

  • RUNTIME: Press Enter for information regarding the fixtures time in use
  • VERSION: Software version information.
  • TEMPERATURE: Information on the lamp temperature
  • FAN SPEED: Information of all the units fan speed

RESET

  • REBOOT: This function will reset all motor functions.
  • DEFAULT DATA: This function will reset to original
  • display factory settings

CHANNEL SET: 39

SIGNAL

  • DMX 512 Framebot 600
  • WDMX = Available on Framebot 600 Pro
  • PROGRAM = Framebot 600
  • Artnet = Available on Framebot 600 Pro

OFFLINE SET

Sets default setting of fixture losses input signal.

  • HOME: Will turn fixture to the home all channels 0 position.
  • HOLD: Will hold the last signal received and will not change till receive new DMX command.

FAN MODE

Sets the fixture fan speed

  • NORMAL: Will adjust the fan speed automatically depending on the fixtures internal temperature (recommended).
  • PERFORMANCE: Fan speed will stay at he highest level to maintain fixtures performance level.
  • QUIET: Fixtures lamp output will be reduced to adjust to fixtures safe operating temperature

WIRELESS SET

Links Wireless Solutions DMX (only available on Framebot 600 Pro)

  • Link Select link from Wireless Transmitter and Link from the display for Wireless DMX Operation (signal will also need to be switched to WDMX)
  • Unlink: Select unlink to disconnect from wireless transmitter

ADJUST

Fine adjustment of motor position

  • All Motor functions can be finely adjusted for best optical path performance

ARTNET SET

Artnet signal setup

  • Available on the Framebot 600 Pro

RDM UID

Manufacture ID

  • RDM Signal, Manufacture UID 6342 ID Mega Lite

LANGUAGE

Display Language Option

  • ENGLISH, RUSSIAN, CHINESE

BACKLIGHT

Display view settings

  • ON: Display will remain always on.
  • OFF: Display will turn off after 30 seconds of no display use.
  • FLASH: Display will turn of after 30 seconds no display use. And the display will flash if DMX signal is lost

REVERSE DISPLAY

Display Orientation

  • ON: Display will remain base to the bottom view.
  • OFF: Display will invert to base on top view.
  • Auto: Display will automatically invert depending base’s position.

SETTING LOCK & KEY LOCK

Display Lock

  • ON: Display will remain base to the bottom view.
  • OFF: Display will invert to base on top view.
  • Auto: Display will automatically invert depending base’s position.

PROGRAM

Manually created programs

SELECT PROGRAMS

  • Select from 1-8 programs you would like to record
  • EDIT PROGRAM: Adjust fixtures channel to be recorded. Press Enter to confirm. (Playback of programs is done in the Setting section under the Signal menu for Programs)

DMX Profile

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
FIG-1

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
FIG-2

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
FIG-3

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
FIG-4

Size and Weight

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
FIG-5

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
FIG-6

MEGA-LITE-Framebot-600-LED-Moving-Head-Framing-Light-
FIG-7

Customer Support

MEGA-Lite has a customer support line to provide set-up help and to answer any questions should you encounter a problem. Please visit our website for any other related technical documents. For service related issues, please contact our service dept.

Monday – Friday 9am to 6pm CST (210)684-2600

Service@mega.lighting

Manual Version

Please visit www.mega.lighting for the most up-to-date manual version.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals