SuperFish 3500 PondECO Plus E Electronic Filter Pump User Manual
- June 6, 2024
- SuperFish
Table of Contents
PondECO Plus E
3500 – 5000 – 8000 – 10000
12000 – 15000 – 20000 – 26000
User manual
Electronic filter pump
Translation of the original manual.
SuperFish PondECO Plus E 3500/5000/8000/10000/12000/15000/20000/26000 Pump
General instructions
Read this manual carefully before using this device. Keep this manual for
future reference.
Meaning of symbols
The following warning symbols and/or signal words are used in this manual:
DANGER!
This means an imminent danger due to electric current. Failure to follow the
safety instructions can result in serious or fatal injury and/or serious
damage to the product or environment.
WARNING!
** This means a dangerous situation. Failure to follow the safety
instructions can result in moderate or minor personal injury and/or damage to
the product or environment.
NOTICE!
This means caution, useful information, or advice.
Fig. … This refers to the relevant drawing … on pages 2 and 3 of this
manual.
Meaning of the symbols on the device itself:
This device is suitable for outdoor use and can be used underwater up to a
2-meter depth.
IP68** This device is waterproof.
This device complies with all applicable EU standards.
This device may not be disposed of with normal household waste but must be
collected separately for recycling.
Use
Suitable for outdoor use, for pumping pond water within the pond, and for
inline set-up.
- The temperature of the pond water being pumped should not exceed 35°C.
- Do not use for pumping saltwater, sewage water, flammable, corrosive, and/or explosive liquids (e.g. petroleum, petrol, solvents), fats, oils, or foodstuffs.
- Never run the device without water.
- Do not use swimming pools and do not connect to drinking water supplies.
Safety
Always follow the safety instructions below for safe use of the device. Failure to follow these instructions may endanger persons or the environment.
- This device must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 mm.
- Ensure the voltage shown on the label matches the main supply voltage.
- This device must be connected to a socket that is earthed.
- Protect the socket and plug against moisture. Use a drip loop to ensure water cannot reach the socket via the cord (see Fig. A).
- Don’t use the product if the device, cord or plug is damaged. Return the device to your dealer for repair or recycling. A damaged cord or plug cannot be replaced, the device should be recycled.
- Be careful with the combination of water and electricity. Do not operate with wet hands. Dry hands before carrying out maintenance.
- Never use the device when there are people in the water. · Always switch off all devices at the mains supply before maintenance.
- Do not move or lift the device out of the water by the cord, only lift the device by the handle.
- **** This device can be used by children aged 8 years and above, persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, if they have been given supervision or instructions concerning the use of the device in a safe way and understand the hazards involved.
- Children shall not play with the device. Cleaning and maintenance of the device shall not be done by children without supervision.
- Modifications to the device may affect its safety. The warranty will also expire.
Function
The PondECO Plus E is an electronic pond pump for use with filters, skimmers,
waterfalls, and water ornaments.
Run Dry Protection
The pump is equipped with a dry-running safety device, which is especially
important when used inline. It is important that water can always be pumped
around. If there is no water flow for 10 seconds, the pump will automatically
stop and then restart after 10 seconds. If there is still no water flow, the
pump will stop and restart again. This cycle is repeated 5 times, after which
the pump stops completely. You can restart the pump when the water supply is
restored. Pull the plug out of the socket, wait 60 seconds, and plug it in
again. The pump will now start up and pump water around.
Thermal overload protection
The pump has thermal overload protection in case the motor overheats, the pump
switches off automatically. After a cooling downtime of 15 to 20 minutes, the
pump automatically switches on again. In order to prevent damage to the pump,
it is essential to investigate the cause of the overheating and resolve the
issue. Damage caused by overheating is not covered by the warranty.
Pond installation
Fig. B The PondECO E pump is suitable for pond hoses with diameters of
25, 32, and 40 mm or 40 and 50 mm.* Cut the Multi-step hose connector to the
desired diameter and fasten it on the pump. · Connect the pond hose to the
hose connector using a hose clamp (not included).
Fig. C Preferably installs the pump in the deepest part of the pond (max.
2-meter depth), or at least 20 cm below the water surface. · Make sure that
the pump stands horizontally and firmly on a flat surface so that it cannot
fall over.
Fig. A Plug the pump into the socket and make sure there is a drip loop
in the cord. · Make sure that no one can trip over the cord and that the cord
cannot be damaged.
Inline installation
Fig. D For inline use, the pump section must be taken out of the housing.
Fig. E Open the housing by pressing the latch at the front and back, which
will release the upper shell. Fig. F Remove the bracket that runs over the
pump by unscrewing the 2 screws and taking the pump out of the housing.
At the front of the pump is the inlet (hose connector not supplied). At the
top is the outlet (for the supplied hose connector).
Fig. B First cut the hose connectors to the desired diameter and then
fasten them to the pump.
Connect the pond hoses to the hose connectors using hose clamps (not
included).
Install the pump horizontally and firmly on a flat surface outside the pond.
Make sure that the pump cannot tip over, if necessary you can secure the pump
with screws.
Fig. A Plug the pump into the socket and make sure there is a drip loop
in the cord.
Make sure that no one can trip over the cord and that the cord cannot be
damaged.
Maintenance
-
The pump should be cleaned regularly (minimum twice a year) to ensure trouble-free operation. Scale deposits, in particular, can cause your pump to cease. There is no warranty on failures due to dirty pumps and scale build-up inside the pump caused by improper or lack of maintenance.
-
Remove the plug from the socket before carrying out maintenance!
-
Disconnect the pump from the pond hose and rinse the housing under the tap or garden hose.
-
For proper cleaning and descaling, it is best to use SuperFish Pump & UVC Clean (Art. 07070500), which is available
from your dealer. -
Mix SuperFish Pump & UVC Clean in a large bucket with clean tap water, according to the instructions on the bottle. Immerse the pump into it and leave it there for 24 hours.
-
Take the pump out of the bucket and let it drain before disassembling it.
-
Fig. E Open the housing by pressing the latch at the front and back, which will release the upper shell.
-
Fig. F Remove the bracket that runs over the pump by unscrewing the 2 screws and taking the pump out of the housing.
-
Dismantle the rotor housing by loosening the 4 screws on the front of the pump and removing the rotor.
-
Brush and clean all parts and the housing thoroughly. Rinse everything with clean tap water and reassemble.
-
Depending on the usage the rotor and rotor housing can get worn out and damaged, this is normal. A new rotor and rotor housing are separately available from your dealer.
-
NOTICE! During periods of frost, you should remove the pump from the pond. Clean and dry the pump well and store it frost-free.
Recycling
This symbol indicates that this product (if it is discarded) may not be
disposed of with normal household waste. Instead, it must be handed in at an
official collection center (e.g. HWRC). Or can be returned to the dealer when
purchasing a similar new product. Follow the applicable rules in your country
for the separate collection of electrical and electronic products. Separate
collection and recycling are better for the environment, public health and
reduce waste.
Warranty
2 years manufacturer’s warranty on materials and construction defects. Devices
must be returned complete with all components, accompanied by an official
proof of purchase confirming a purchase date for any warranty claims.
Incomplete devices in which parts are missing, and devices without proof of
purchase are not eligible for a warranty. After receiving and checking, we
will determine whether the device will be repaired or replaced. For a device
repaired or replaced under warranty, the remaining time of the original
warranty period applies. Carefully read the instructions on installation, use,
and maintenance. Damage due to incorrect use, damage due to contamination or
not cleaning the device, wear and damage to the rotor, and damage to the cord
are not covered by the warranty. Always keep the proof of purchase, without
proof of purchase the warranty will be void!
Pick-up & Replace Warranty
This PondECO Plus E /RC pump comes with a unique 2-year warranty with 48 hours
of on-site Pickup and Replace service. In the event of a defect, the pump is
picked up within 48 hours and immediately replaced free of charge by a new one
(from Monday to Friday, with no deliveries on Saturday and Sunday). Subject to
proper use and maintenance (regularly descaled and cleaned, cord and rotor not
damaged). To qualify for this 48 hours Pick-Up & Replace Warranty, you must
register within 1 month after purchasing the PondECO Plus E or RC pump. To
register, simply fill out the enclosed registration form in full and return it
with a copy of the purchase to Aquadistri. If you do not register by the
aforementioned deadline, the 48 hour Pickup and Replace Warranty will not be
valid. For any problems during the warranty period, simply contact your
dealer. The Pick-Up & Replace Warranty is only applicable in the Netherlands,
Belgium, Luxembourg, Germany, France, and the United Kingdom. For residents of
other countries the normal warranty applies, for this, you need to contact the
dealer where the pump was purchased.
Technical specifications
PondECO Plus E | 3500 | 5000 | 8000 | 10000 | 12000 | 15000 | 20000 | 26000 |
---|---|---|---|---|---|---|---|---|
Pump capacity | 3,500 l/h | 5,000 l/h | 7, 8 0 0 l / h | 9,200 l/h | 11,200 l/h | |||
15,000 l/h | 19,500 l/h | 25,100 l/h | ||||||
Head | 2.0 m | 3.0 m | 4.2 m | 5.8 m | 6.0 m | 6.5 m | 6.0 m | 8.2 m |
Power | 14 Watt | 22 Watt | 41 Watt | 68 Watt | 85 Watt | 130 Watt | 150 Watt | 240 |
Watt
Hose connector Ø| | 25/32/40 mm| | | 40/50 mm
Spare parts (Art.)| 3500| 5000| 8000| 10000| 12000| 15000| 20000| 26000
---|---|---|---|---|---|---|---|---
Rotor| 7070430| 7070435| 7070440| 7070443| 7070445| 7070450| 7070505| 7070303
Rotor housing| 7070475| 7070476| 07070477| 7070478| 7070480| 7070509| 7070307
Hose connector (OUTLET| 7070485| 07070487| 7070492| 7070511| 7070309
Hose connector (INLET)| 7070485| 07070487| 7070487| 7070511| 7070309
Important, clean your pump at least twice a year!
Scale deposits ensure that dirt and algae adhere more easily to your pump,
causing wear. Descale your pump at least twice a year, for smooth, long-term
use. In areas with extremely hard water, you may need to descale more often.
Technical problems caused by scale are not under warranty. For cleaning and
descaling, your pump special SuperFish Pump & UVC Clean is available at your
dealer.
Date of purchase…………………..
Technical specifications:
Pump: 220-240 V/50 Hz.
Size: 30 x 25.5 x 14.75 mm
Cord: 10 metres
www.aquadistri.com
Vlietweg 8, 4791 EZ Klundert,
The Netherlands, info@aquadistri.com
References