ZKTeco EX0808 I/O Board for USB US-InBio-Pro Panels User Guide
- June 6, 2024
- ZKTECO
Table of Contents
- ZKTeco EX0808 I/O Board for USB US-InBio-Pro Panels
- Product PIN Diagram
- LED Status Indicator
- DIP Switch Setting for RS485/0SDP Communication
- Connecting to the Controller
- Connecting to ZKBioSecurityVS000 Software
- Operating via the Software
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
ZKTeco EX0808 I/O Board for USB US-InBio-Pro Panels
Product PIN Diagram
EX0808 is an extended module for controllers which is used for connecting more number of auxiliary devices.
0 | RS485 In | Used for RS485 communication. |
---|---|---|
6 | RS485 Out | Used to connect another EX0808 expansion board. |
@ | Aux Output | Used to connect upto 8 auxiliary output devices. |
0 | Aux Input | Used to connect upto 8 auxiliary input devices. |
0 | Power Input | DC12V-3A. |
0 | __ |
DIP Switch
| Sets the RS485/OSDP address of the EX0808 and set the RS485/OSDP
communication etc.
0| DIP Switch Instructions| Introduces the use of DIP switches.
(i)| RUN lndicator(Green)| Indicates the running states.
0| COMM lndicator(Yellow)| Indicates the communication states of the
RS485.
LED Status Indicator
DIP Switch Setting for RS485/0SDP Communication
Notes:
There are six DIP switches on the EX0808 expansion board and their functions
are:
- Switches 1 to 4 are used to set the RS485/OSDP addresses.
- Switch 5 is for RS485/OSDP mode switching. When set to OFF, RS485 mode is used, and when set to ON, OSDP mode is used.
- If the cable length is more than 200 meters, the switch 6 should be ON for noise reduction on long RS485 cables.
Connecting to the Controller
Use the software after connecting the EX0808 module to the controller. The EX0808 module can be connected to the inBioX60 Pro Series. The connection with inBio460 Pro is shown as an example below:
Notes:
- A maximum of eight EX0808 extended boards can be connected to an inBio460 Pro controller.
- Each EX0808 can connect a maximum of eight auxiliary input devices and eight auxiliary output devices.
- A separate power supply is required for each EX0808.
- Set the RS485/OSDP addresses of each EX0808 by the DIP switch before power is supplied.
Connecting to ZKBioSecurityVS000 Software
After wiring, please follow the below steps:
-
Add inBio460 Pro controller on the software.
-
Login to ZKBioSecurityVS000 software and click on Access> Device> Device> Search, to search the device on the software. The searched devices are displayed automatically.
-
First, change the IP address of the device by clicking Modify IP Address. Then a new window will pop-up, enter the relevant information and click OK. Device Name: Enter new IP address. New Server Address: Enter the IP address of the server (PC). New Server Port:The current system communication port (prompt under the search page). c. Click Add to add the device on the software.
Note : The IP addresses of the server (PC) and the device must be in the same network segment. -
Add the EX0808 on the software: Click Access> Device> 1/0 Board> New to add the EX0808 on the software. Enter the name and RS485/OSDP address of the EX0808. Set the RS485/OSDP address of the EX0808 from 1-15. Then click OK to save and exit.
-
On the software, click Access> Device> Auxiliary Input/ Auxiliary Output to view all the auxiliary inputs/outputs.
Operating via the Software
Remoteoperation
- On the software, click Access> Device> Auxiliary Output to view all the auxiliary outputs.
- Select the auxiliary output and clickRemoteOpen,a new window will pop-up.
- Enter the relevant information and click Start. You will be able to remotely open the device connected to the auxiliary output via software.
Linkagefunction
On the software, click Access > Access Control > Linkage > New and fill in all
the relevant information to set a new linkage operation.The operation is as
follows:
- First, select an auxiliary device on the list and click Device to choose.
- Click Add to add the linkagetrigger condition from drop-down and select the input point on the list.
- Set the output point of the Door and the Auxiliary Output.
- Select action type and set the action time delay then click OK to save and exit.
For more details, please refer to the ZKBioSecurityVS000 User Manual.