Edge-core ECS2100 Series 52-Port Gigabit Web-Smart Pro Switches User Guide

June 10, 2024
Edge-core

Edge-core ECS2100 Series 52-Port Gigabit Web-Smart Pro Switches

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches

Unpack the Device and Check Contents

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-1

Note :

  • The ECS2100 TIP series devices are for indoor use only.
  • For Safety and Regulatory information, refer to the Safety and Regulatory Information document included with the device.
  • Other documentation, including the Installation Guide, Web Management Guide, and CLI Reference Guide, can be obtained from www.edge-core.com

Mount the Device

a. Mounting in a Rack

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-2

  1. Attach the brackets to the device.
  2. Use the screws and cage nuts supplied with the rack to secure the device in the rack.

Caution : Installing the device in a rack requires two people.
One person should position the device in the rack, while the other secures it using the rack screws.

Note : The device can also be installed on a desktop or shelf using the included adhesive rubber foot pads.

b. Mounting in a Rack (ECS2100-10PE TIP only)

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-3

Caution : For safe operation, install the device with RJ-45 ports facing up.

  1. Set two screws in the wall 150 mm (5.9 in.) apart.
  2. Slide the device’s wall mounting slots down onto the screws so that the unit is secure.

Ground the Device

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-4

  1. Ensure the rack on which the device is to be mounted is properly grounded and in compliance with ETSI ETS 300 253.
    Verify that there is a good electrical connection to the grounding point on the rack (no paint or isolating surface treatment).

  2. Attach a lug (not provided) to a #12 AWG (PoE device) or #18 AWG (non-PoE device) minimum grounding wire (not provided), and connect it to the grounding point on the device rear panel. Then connect the other end of the wire to rack ground.

Caution : The earth connection must not be removed unless all supply connections have been disconnected.
Caution : The device must be installed in a restricted-access location. It should have a separate protective earthing terminal on the chassis that must be permanently connected to earth to adequately ground the chassis and protect the operator from electrical hazards.

Connect Power

a. Connect AC Power

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-5

  1. Plug the AC power cord into the socket on the rear of the device.
  2. Connect the other end of the power cord to an AC power source. Verify that the external AC power requirements for the device can be met as listed below:
    ECS2100-10T TIP: AC 100-240 V, 50-60 Hz, 0.5 A ECS2100-10P TIP: AC 100-240 V, 50-60 Hz, 2.1 A ECS2100-28T TIP: AC 100-240 V, 50-60 Hz, 0.5 A (Not for China), AC 100-240 V, 50/60 Hz, 0.5 A
    ECS2100-28P TIP: AC 100-240 V, 50-60 Hz, 3.2 A ECS2100-28PP TIP: AC 100-240 V, 50-60 Hz, 5.8 A ECS2100-52T TIP: AC 100-240 V, 50/60 Hz,1 A

Warning : For the ECS2100-10P TIP, the bottom of the enclosure is a hot surface. Do not touch!
Note : For International use, you may need to change the AC line cord. You must use a line cord set that has been approved for the socket type in your country.

b. Connect DC Power to ECS2100-10PE TIP

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-6

Note : The ECS2100-10PE TIP includes an AC-DC power adapter. Connect the AC-DC power adapter to the device and to an AC power source. The AC-DC adapter provides 54 VDC, 1.67 A of power to the device.

  1. Plug the DC power cable into the socket on the rear of the device.
  2. Plug the AC-DC power adapter into a nearby AC power outlet.

Verify Device Operation

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-7

  1. Verify basic device operation by checking the system LEDs.
    When operating normally, the Power and Diag LEDs should be on green.

Perform Initial Configuration

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-8

  1. Connect a PC to the device console port using the included console cable.
  2. Configure the PC’s serial port: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.
  3. Log in to the CLI using default settings: Username “root” and password “open wifi.”
    Note : For further information on device configuration, refer to the Web Management Guide and CLI Reference Guide.

Connect Network Cables

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-9

  1. For RJ-45 ports, connect 100-ohm Category 5, 5e or better twisted-pair cable.
  2. For the SFP/SFP+ slots, first install SFP/SFP+ transceivers and then connect fiber optic cabling to the transceiver ports. The following transceivers are supported:
    • 1000BASE-SX (ET4201-SX)
    • 1000BASE-LX (ET4201-LX)
    • 1000BASE-ZX (ET4201-ZX)
    • 1000BASE-LHX (ET4201-LHX)
    • 10GBASE-SR (ET5402-SR)
    • 10GBASE-LR (ET5402-LR)
    • 10GBASE-ER (ET5402-ER)
  3. As connections are made, check the port status LEDs to be sure the links are valid. Press the Mode button to change from Ethernet to PoE status:
    • On/Blinking Green — Port has a valid link. Blinking indicates network activity.
    • On Amber — Port is supplying PoE power.

Hardware Stacking Connection (Optional)

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-10

  1. Install the ECS2100-28PP TIP in a standard 19-inch rack and power on.
  2. Install the PS3000 chassis in a standard 19-inch rack.
  3. Install one or more EPS460W PSUs in the chassis. The chassis can support up to three EPS460W PSUs.
  4. Use the PSU cable (provided) to connect each EPS460W PSU to an ECS2100-28PP TIP device.
  5. Connect the AC power cord to power on the EPS460W PSU, and check the LEDs on the PSUs to ensure proper operation. The Link LEDs for connected devices should light up.

Initial Setup and Registration

There are two options for setting up the device for your network:
When the device is first connected to the Internet through a network port, it is automatically redirected to ecOpen (https://cloud.openwifi.ignitenet.com/). Enter the device’s MAC address and serial number for registration.

By default, the device is assigned an IP address through DHCP. If the device cannot connect to ecOpen, access the device’s web interface through one of the device’s RJ-45 ports to make configuration changes (for example, to change from DHCP to a static IP). See section “Connecting to the Web Interface”.

Connecting to the Web Interface

Note that you can only connect to the device’s web interface when the device is not connected to the Internet.
Follow these steps to connect to the device’s web interface through a network connection to one of the device’s RJ-45 ports.

  1. Connect a PC directly to one of the device’s RJ-45 ports.
  2. Set the PC IP address to be on the same subnet as the device RJ-45 port default IP address. (The PC address must start 192.168.2.x with subnet mask 255.255.255.0.)
  3. Enter the device’s default IP address of 192.168.2.10 into the web browser address bar.
  4. Log in to the web interface using the default user name “root” and password “openwifi”.

Note : The TIP OpenWiFi SDK default URL of the DigiCert certificate is set to ecOpen: (https://cloud.openwifi.ignitenet.com). If you want to register the device to your own TIP OpenWiFi SDK, contact oxherd@edge- core.com to change the default URL.

Hardware Specifications

Device Chassis
Size (W x D x H)

  • ECS2100-10T TIP: 19.64 x 11.71 x 3.66 cm (7.73 x 4.61 x 1.44 in.)
  • ECS2100-10P TIP: 33.0 x 20.4 x 4.26 cm (12.99 x 8.03 x 1.67 in.)
  • ECS2100-10PE TIP: 24.0 x 15.5 x 2.65 cm (9.44 x 6.10 x 1.04 in.)
  • ECS2100-28T TIP/28P/28PP/52T: 44 x 22 x 4.4 cm (17.32 x 8.66 x 1.73 in.)

Weight

  • ECS2100-10T TIP: 816 g (1.8 lb)
  • ECS2100-10P TIP: 2.4 kg (5.34 lb)
  • ECS2100-10PE TIP: 973 g (2.15 lb)
  • ECS2100-28T TIP: 2.2 kg (4.86 lb)
  • ECS2100-28P TIP: 2.8 kg (6.18 lb)
  • ECS2100-28PP TIP: 3.1 kg (6.85 lb)
  • ECS2100-52T TIP: 2.5 kg (5.5 lb)

Temperature

  • Operating: 0°C – 50°C (32°F – 122°F)
  • Operating: 0°C – 45°C (32°F – 113°F, ECS2100-28PP TIP only)
  • Operating: 0°C – 40°C (32°F – 104°F, ECS2100-10P TIP and ECS2100-28PP TIP with one EPS460W only)
  • Storage: -40°C – 70°C (-40°F – 158°F)

Humidity Operating: 10% – 90% (non-condensing)

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-13

Edge-core-ECS2100-Series-52-Port-Gigabit-Web-Smart-Pro-
Switches-14

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals