Edge-core OAP100e 802.11ac Wave 2 Dual-Band Enterprise Access Point User Guide
- June 5, 2024
- Edge-core
Table of Contents
Quick Start Guide
802.11ac Wave 2 Dual-Band Enterprise Access Point
OAP100e
Package Contents
1. OAP100e access point
2. Mounting kit–2 brackets and 2 steel hose clamps
3. (Optional) Mounting bracket
4. DC Terminal plug
5. 2 x Cable glands| 6. 2 x Port covers
7. 2 x External 5G omni antennas
8. Console cable–RJ-45 to DB-9
9. QR code card
---|---
Overview
|
---|---
-
Grounding point
-
Console port
-
LAN (PoE Out) port: 1Gbps connection to LAN devices
-
Uplink (PoE In) port: 1Gbps uplink connection with 802.3at PoE support
-
DC In port: 24 Vdc
-
5G Antenna connector
-
Mounting points
-
Enclosure for optional module
-
LEDs:
■ Power: On red (power OK)
■ System: On green (power OK), Blinking (boot up)
■ Uplink: On amber (1Gbps link), On green (10/100Mps link), Blinking (traffic)
■ LAN: On amber (1Gbps link), On green (10/100Mps link), Blinking (traffic)
■ LTE: function not supported
■ 2.4G: On blue (radio on), Blinking (traffic)
■ 5G: On blue (radio on), Blinking (traffic) -
Reset button
Installation
Warning: For a safe and reliable installation, use only the accessories and screws provided with the device. The use of other accessories and screws could result in damage to the unit. Any damages incurred by using unapproved accessories are not covered by the warranty.
Avertissement: Pour une installation sûre et fiable, utilisez uniquement les accessoires et les vis fournies avec l’appareil. L’utilisation d’autres accessoires et vis pourrait endommager l’appareil. Les dommages causés par l’utilisation d’accessoires non approuvés ne sont pas couverts par la garantie.
Note: The drawings in this document are for illustration only and may not match your particular model.
- Mount the AP
The included mounting brackets are designed for pole mounting and provide
additional degrees of movement for antenna alignment.
a. Using a Single Bracket (Parallel)
- Install the bracket onto the AP using the included four screws.
- Thread the included steel hose clamps through the eyelets on the back of the Mounting Bracket and then lightly fasten them around the pole. Both hose clamps must be used for pole mounting.
b. Using Two Brackets (Tilt)
-
Attach the two main sections of the bracket using the four included screws and locknuts.
-
Install the bracket onto the AP using the included four screws.
-
Thread the included steel hose clamps through the eyelets on the back of the Mounting Bracket and then lightly fasten them around the pole. Both hose clamps must be used for pole mounting.
c. (Optional) Using Two Brackets (Perpendicular)
-
Attach the two main sections of the bracket using the four included screws and locknuts. This requires an optional bracket.
-
Install the bracket onto the AP using the included four screws.
-
Thread the included steel hose clamps through the eyelets on the back of the Mounting Bracket and then lightly fasten them around the pole. Both hose clamps must be used for pole mounting.
2 Ground the AP
Ground the AP by connecting a ground wire to the grounding point on the device and to the nearby good earth.
3 Install the 5G Antennas
Install approved cellular 5G Omni external antennas to improve coverage and performance.
3 Connect Cables
a. Connect LAN Cables
Note: Port covers and cable glands should be tightened to a torque of 10 kgf. cm.
- Connect Category 5e or better cable to the Uplink (PoE In) 1000BASE-T RJ-45 port. When connected to a PoE source, the Uplink (PoE In) port connection provides power to the unit.
- (Optional) Connect a local LAN switch, computer, or another device to the LAN (PoE Out) 1000BASE-T RJ-45 port.
b. (Optional) Connect DC Power
When not connected to a PoE source, wire the included DC terminal plug to a 1024 VDC, 0.5-1 A source to provide power to the AP.
c. (Optional) Management Connections
Connect an RJ-45 to DE-9 straight-through console cable and then configure the serial connection: 115200 bps, 8 characters, no parity, one stop bit, 8 data bits, and no flow control.
4 Check AP LEDs
Power and System LEDs–on green for normal operation.
5 Connect to the Web User Interface
-
Connect a PC directly to the AP’s LAN (PoE Out) port.
-
Set the PC IP address to be on the same subnet as the AP LAN port default IP address. (The PC address must start 192.168.1.x with subnet mask 255.255.255.0.)
-
Enter the AP’s default IP address of 192.168.1.10 into the web browser address bar.
Note: To connect to the web interface using the Uplink (PoE In) port, the IP address is automatically assigned through DHCP by default. If a DHCP server is unreachable, the Uplink(PoE) port reverts to a fallback IP address of 192.168.1.10. -
Log in to the web interface using default settings:
Username = admin
Password = admin
Safety and Regulatory Information
FCC Class B
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna
- Increase the separation between the equipment and receiver
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
- Consult the dealer or an experienced radio/TV technician for help
FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
For products available in the USA/Canada market, only channel 1~11 can be operated. Selection of other channels is not possible.
IMPORTANT NOTE:
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 46 cm between the radiator and your body.
Professional Installation Instructions
-
Installation personnel
This product is designed for specific applications and should be installed by qualified personnel who have knowledge of RF and its related regulations. A general user shall not attempt to install or modify the equipment configuration. -
Installation location
To meet regulatory RF exposure requirements, this product shall be installed at a location where, during normal operations, the radiating antenna is at least 45 cm away from any nearby persons. -
External antenna
Use only the antennas which have been approved by the applicant. Using non- approved antenna(s) is prohibited and may produce unwanted spurious or excessive RF transmitting power which may lead to a violation of FCC limits. -
Installation procedure
Please refer to this equipment’s user manual for the procedure details. -
Warning
The installation position must be carefully selected so that the final output power does not exceed the limit set forth in relevant regulations. Violation of output power regulations could lead to serious federal penalties.
Industry Canada
This device contains license-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science, and Economic Development Canada’s license-exempt
RSS(s). Operation is subject to the following two conditions:
(1) This device may not cause interference.
(2) This device must accept any interference, including interference that may
cause undesired operation of the device.
The device for operation in the band 51505250 MHz is only for indoor use to reduce the potential for harmful interference to co-channel mobile satellite systems.
CE Statement
This equipment complies with EU radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance 20 cm between the radiator and your body.
The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range.
All operational modes:
2.4 GHz: 802.11b, 802.11g, 802.11n (HT20), 802.11n (HT40), 802.11ac (VHT20),
802.11ac (VHT40), 802.11ax (HE20), 802.11ax (HE40)
5 GHz: 802.11a, 802.11n (HT20), 802.11n (HT40), 802.11ac (VHT20), 802.11ac
(VHT40), 802.11ac (VHT80), 802.11ax (HE20), 802.11ax (HE40), 802.11ax (HE80)
BLE 2.4 GHz: 802.15.1
The frequency and maximum transmitted power limit in the EU are listed
below:
2412-2472 MHz: 20 dBm
5150-5350 MHz: 23 dBm
5500-5700 MHz: 30 dBm
AT | BE | BG | CH | CY | CZ |
---|---|---|---|---|---|
DE | DK | EE | EL | ES | Fl |
FR | HR | HU | IE | IS | IT |
LI | LT | LU | LV | MT | NL |
NO | PL | PT | RO | SE | SI |
SK | TR | UK |
The abbreviations of the countries, as prescribed in the above table, where any restrictions on putting into service or any requirements for authorization of use exist.
CE Mark Declaration of Conformance for EMI and Safety (EEC)
This information technology equipment is in compliance with the Directive
2014/53/EU and Directive 2014/35/EU.
The Declaration of Conformity (DoC) can be obtained from www.edge-
core.com->support->download.
Warnings and Cautionary Messages
Warning: This product does not contain any serviceable user parts.
Warning: Installation and removal of the unit must be carried out by
qualified personnel only.
Caution: Wear an anti-static wrist strap or take other suitable measures
to prevent electrostatic discharge when handling this equipment.
Caution: Do not plug a phone jack connector in the RJ-45 port. This may
damage this device.
Caution: Use only twisted-pair cables with RJ-45 connectors that conform
to FCC standards.
Hardware Specifications
AP Chassis
Size (WxDxH) | 230 x 450 x 65 mm (9.06 x 17.72 x 2.56 in.) |
---|---|
Weight | X.XX kg (X.XXX lb) |
Temperature | Operating: -40° C to 65° C (-40° F to 149° F) Storage: -40° C to |
70° C (-40° F to 158° F)
Humidity| Operating: 5% to 95% (non-condensing)
Network Interfaces
Ports| Uplink (PoE In) RJ-45 Port: 1000BASE-T, PoE PD
LAN (PoE Out) RJ-45 Port: 1000BASE-T, PoE PSE
---|---
2.4 GHz Radio| IEEE 802.11b/g/n
5 GHz Radio| IEEE 802.11a/ac/n
Bluetooth| BLE/BT4.1
Radio Frequencies| 2.42.4835 GHz (US and ETSI) US 5.155.25 GHz (lower band)
5.7255.825 GHz (upper band)
Europe 5.155.25 GHz, 5.255.35, 5.475.725 GHz
Power Specifications
PoE Input Power | 22.4 W max 802.3at-compliant |
---|---|
DC Power | 24 VDC, 1.09 A |
Regulatory Compliances
Radio| EN 300 328 V2.2.2 (2.4G/BT-LE)
EN 301 893 V2.1.1 (5G)
EN 303 413 V1.1.1 (GPS)
EN 50385 / EN 62311: 2017 (MPE)
---|---
Emissions| EN 301 489-1 V2.1.1
EN 301 489-17 V3.1.1
EN 301 489-52 V1.1.0
Safety|
EN 62368-1: 2014 + A11: 2017
EN 60950-22: 2017 IEC 62368-1: 2014 (Second Edition) IEC 60529: 1989+AMD1:
1999+ AMD2: 2013CSV (IP55)
Warranty Information and Technical Support
Registering your product enables you to receive a more efficient warranty
service. Be sure to register at www.edge-core.com.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>