OPCOM OFG003 Farm Grow Wall 3 Vertical Hydroponic Unit User Guide

June 5, 2024
OPCOM

OPCOM OFG003 Farm Grow Wall 3 Vertical Hydroponic Unit

OPCOM OFG003 Farm Grow Wall 3 Vertical Hydroponic Unit-
Product

Planting

Sowing Stage

Refer to the below table for sponge quantity and planting numbers.OPCOM
OFG003 Farm Grow Wall 3 Vertical Hydroponic UnitFig13

  • Add water to the seedling tray, up to the water level.
  • Open Grow Sponge package, put the sponges into the water of the seedling tray, press the sponges into water for 5 seconds and ensure the sponges absorb water completely.(Fig1)
  • Place the seedling tray with cover in the shade or cover it with black cloth(to block light).
  • Spray water and keep the sponges wet every day.
  • During 0-7 days(leaf plant), find the sprouted ones in the tray; pick them out, move them into the growing holes and keep the remaining seedlings.
  • Discard unsprouted sponges after regular germination time.
  • The different plants may have different germination times, please check before planting.
  • Chart II: Plant Stage.

OPCOM OFG003 Farm Grow Wall 3 Vertical Hydroponic
UnitFig14

Seedling Stage

  • When the germination rate exceeds 70%, move to the seedling stage, and discard excess sponges. Move all sponges to the grow tube and set them up in balance depending on plant size. In each sponge, keep strong plants and cut the other weak plants.
  • Use a spoon to add the nutrition powder to the water tank and ensure that the EC is between 1000-2000 μS/cm.(=1.0-2.0 ms/cm).
  • Ensure pH between 5.5-6.5 (adjust by pH adjusters). 13 inches Adjust LED lights and keep around 2 inches distance to cover all the plants.
  • For EC & pH adjustment instructions, please refer to user manual pages 28-29.
  • B3. Growing Stage
  • When young plants grow to over 2 inches in height, change the control box to AUTO mode.
  • Grow to Harvest
  • Growing Stage
  • UO when young plants grow to over 2 inches in height, change the control box to AUTO mode
  • Grow to Harvest
  • After 4-6 weeks, harvest larger plants for consumption.
  • UO Reserve smaller plants to grow.
  • To save time, sow the new seeds in the sprout box for the next planting cycle before a week of harvesting.
Optional

Regrowing

OPCOM Farm is designed with a special re-grow process to maximize harvest capacity for family consumption. The first harvest cycle takes 3-4 weeks after the seeding the young plant is planted. During harvesting, cut out the larger leaves and allow the smaller ones to continue to grow in the machine. After the first harvest, you can continue the harvesting method weekly for the next 3-4 weeks without the need to re-seed.

Sprout Process

GrowWall is not only a hydroponics system but also a Sprout Machine with our free gift, a sprouting box. Within one Hydroponics cycle time, you can have 3-4 sprout harvests and each harvest cycle is 7-10 days. Enjoy your maximum planting capacity. Refer to user manual pages 24-25 for details.

Troubleshooting

Lamps are not

lighting up

| ☑ Make sure all power cables are connected.
---|---
☑ Power button is turned ON.
☑ Make sure LED status is not OFF.
☑ If on AUTO, HI or LOW there will be periods of time during a 24-hour cycle when lamps are off.

(See the user manual page 15 for cycle descriptions.)

☑ If a lamp has burned out or does not work, replace with a new OPCOM LED tube (OAEE07A).
Pump is not working| ☑ Make sure the pump’s cable is correctly plugged into the control box.

☑ Make sure Pump status is not OFF.

☑ If on AUTO, HI or LOW there will be periods of time during a 24-hour cycle when lamps are off.

(See the user manual page 15 for cycle descriptions.)

☑ If the pump still does not work, replace it with a new OPCOM pump (OAEE06A). Refer to pump box for installation.
The pump has a buzzing sound| ☑ Pump may give off a buzzing sound in the beginning due to air inside the pump. After a minute with water

running through the pump, this should be reduced.

☑ Too low of a water level in your GrowWall may have resulted in the air entering the pump. Over time this may shorten

the life of the pump. Please maintain the correct water level at all times.

☑ If the pump is failed, replace it with a new OPCOM pump (OAEE06A). Refer to pump box for installation.
The lamp or the pump stopped working after a few hours| ☑ Opcom Farm’s control box is designed with Auto, HI, and LOW cycles, which will turn the lamps and the pump on

and off at certain intervals. This is to mimic an outside daily cycle, offering the best growing condition for your plants, and saving you energy.

☑ Check the user manual page 15 for cycle descriptions.

GrowWall Q&A

The pump was

running without water.

| This can shorten the life of the pump. Maintain proper water level. Always keep water above the red line.
---|---
What type of lamps can be used in the GrowWall?| The lamps provided with your GrowWall are standard OPCOM 30W (L30T) LED Growth Tube. This is suitable for most plants’ growth. You may also use OPCOM Professional LED Growth Tube 65W (L65T) to accommodate special growth needs.
Product leakage When it works.| During the delivery in vessels, aircraft, or other vehicles, it may lead to damages in GrowWall(OFG003)/

GrowWall2(OFG003-2) and create a leaking problem. OPCOM FARM provides waterproof tape for you to fix it in case of damage happened.

Maintenance

Change Water

After a cycle of planting, you may want to change water or clean the unit. Check the user manual

EC / pH Meter Use and Calibration

  • Keep the electrode clean from EC/pH meter and cover the electrode protective cap when not in use.
  • Take out the batteries when not in use for an extended amount of time.
  • For the calibration please check the user manual

Installation steps of water pump

Prepare the backup pump.

Connect the water pipe to the pump, then put the pump into the water tank.

As shown in the figure, there are two holes at the top side of the water tank. One is used for a water pipe, the other is for the power cord.

Connect the power cord from the pump to the curve pipe.

Make sure to complete all connections, now the new pump is ready to startup.

Planting Q &A

  • Q1: Sprouts are stuck in the sponge and cant come out.
  • A1: Pull the sprouts gently out from the sponge with tweezers, and make sure the seed capsule’s top half is not stopping the growth of a sprout.
  • Q2: Leaves are smaller or color changed to yellow.
  • A2: Make sure the sponge or plant’s root is soaking in water. If not, add more water to reach the standard level. Check EC and pH according to the manual.
  • Press the Pump button to HI to increase water and airflow to the plants.
  • Press the LED button to ON to give more light per cycle to plants.
  • Q3: Slender leaves and long stems.
  • A3: The plant may need more light. Lower the LED lamps and ensure all plants are covered. Press the LED button to ON to make it brighter. To see more information of planting, please refer to GrowWall planting Q&A.
    For more information, please visit www.opcomfarm.com

Assembly

Remove all parts from the box and check all accessories.

Assemble GrowWall

  • Lock the matching color vertical tubes with an integrated fastener. Repeat the previous action again. Place the plastic peg into the round hole in the bracket; affix the tube and the bracket to the unit. And cover the top-level light holder. Attach the control box by aligning the holes. Assemble water pipe and plastic tiles.
  • Mount on the wall. Place against the wall at 8.2 inches (21cm) distance. Ensure the air bubble on the level scale is centered. Mount on the wall with adhesive or screws. Add 7.13 gallons (80% full) of water to the water tank.
  • Turn on the pump for 30 minutes and ensure the water flows back to the tank, please refer to user manual page 15 for cycle descriptions.
  • Water flow control valve: According to different plants, you can adjust the water flow by water flow control valve, but you need to adjust it underwater.

Control Box Mod

OPCOM OFG003 Farm Grow Wall 3 Vertical Hydroponic
UnitFig7

  • Most plants can be grown using the AUTO mode.
  • When Power On, press the hold POWER button until 2 beep sound (About 5 seconds) to reset power on the timeline.
  • When Power Off, press the hold POWER button until 2 beep sound (About 5 seconds) to reset the power of the timeline.