satel SLIM-DUAL-PET Digital Dual Technology Motion Detector
Instruction
The device should be installed by qualified personnel. Prior to installation, please read carefully this manual. Changes, modifications, or repairs not authorized by the manufacturer shall void your rights under the warranty. SATEL aims to continually improve the quality of its products, which may result in changes in their technical specifications and software. Current information about the changes being introduced is available on our website. Please visit us at: https://support.satel.eu The SLIM-DUAL-PET detector detects movement in the protected area. This manual applies to the detector with electronics version F.
Features
Motion detection with two sensors: passive infrared sensor (PIR) and microwave sensor (MW).
- Adjustable detection sensitivity of both sensors.
- Digital motion detection algorithm.
- Digital temperature compensation.
- A Digital filter of signals received by the microwave sensor ensures immunity to false alarms caused by the power network and gas-discharge lamps.
- A wide-angle lens is designed especially for SLIM detectors.
- Pet immunity up to 20 kg.
- Built-in end-of-line resistors (2EOL: 2 x 1.1 kW).
- LED indicator.
- Selectable color for alarm indication by LED (4 colors available).
- Remote LED enables/disabled.
- Supervision of motion detection system and supply voltage.
- Tamper protection against opening the enclosure.
Description
- The detector will report an alarm when the infrared sensor (PIR) and microwave sensor detect motion within a time period shorter than 3 seconds.
- Supervision features
- In the event of the voltage drop below 9 V (±5%) for more than 2 seconds or the motion detection system failure, the detector will signal trouble. The trouble is indicated by the alarm output activation and the LED indicator coming on. Signalling will continue as long as the trouble exists.
LED indicator
The LED indicates
warm-up – flashing purple for about 30 seconds
- motion detected by microwave sensor – ON for 3 seconds (green color)
- motion detected by PIR sensor – ON for 3 seconds (purple color)
- alarm – ON for 2 seconds (default color: blue)
- trouble – steady ON for the entire duration of the trouble (the same color of lighting as in case of alarm).
You can configure the following LED settings
- select the color to be used to indicate alarm/trouble,
- enable/disable signaling of motion detection by microwave and PIR sensors. For detailed information, please refer to the section “Configuring LED indicator settings”.
Enabling the LED by using a jumper
If you put a jumper across the LED pins, the LED will be enabled, i.e., it will indicate the above-described events (the LED can’t be enabled/disabled remotely). If you do not put a jumper across the pins, the LED will be disabled, but it can be enabled/disabled remotely.
Remote LED enable/disable
The LED terminal is provided to allow remote LED enable/disable. When the terminal is connected to common ground, the LED is enabled. When the terminal is disconnected from common ground, the LED is disabled. If the detector is used in the INTEGRA / INTEGRA Plus alarm system, you can connect to the terminal an OC type control panel output programmed e.g., as “Zone test status” or “BI switch”.
Electronics board
Do not touch the pyroelectric sensor, so as not to soil it.
Terminal block
- NC – alarm output (NC relay);
- TMP – tamper output (NC);
- LED – enable/disable the LED indicator;
- COM – common ground;
- 12V – power input.
Microwave sensor
pins for configuration of the detector outputs. Available settings are shown in the figures
- 2 – built-in resistors are used – to connect the detector outputs as shown in Fig. 9.
- 3 – built-in resistors are not used – connect the detector outputs as shown in Fig. 8.
- 4 SLIM-DUAL-PET SATEL pins to enable/disable the LED indicator.
- potentiometer for adjustment of the microwave sensor sensitivity.
- LED indicator. potentiometer for adjustment of PIR sensor sensitivity.
- fixing screw hole. tamper switch.
- PIR sensor (quad element pyro sensor).
Selecting a mounting location
Do not install the detector outdoors (A)
- Install the detector at the recommended height (B). Test different mounting heights to see where to install the detector in order to achieve the optimal coverage area. You may need to install the detector at a height other than the recommended, e.g., several centimeters down.
- When choosing the installation location, keep in mind that the detector performance will be the best where the expected direction of the intruder movement will be across the coverage pattern (C). · Do not install the detector in places where it will be exposed to direct sunlight (D) or light reflected from other objects (E).
- Do not point the detector towards fans (F), air conditioners (G) or heat sources (H).
Installation
- Disconnect power before making any electrical connections. If the detector is to be pet immune, it must not be mounted on the bracket and must be installed at a height of up to 2.4 m with no inclination from the vertical.
- Remove the front cover
- Remove the electronics board
Make the openings for screws (Fig. 6) and cable (Fig. 7) in the enclosure base.
- Pass the cable through the prepared opening.
- Secure the enclosure base to the wall.
- The wall plugs (anchors) delivered with the device are intended for concrete, brick, etc. For other types of surfaces (drywall, Styrofoam), use the appropriately selected wall plugs.
Fasten the electronics board.
- Connect the wires to the corresponding terminals.
- Configure the detector settings.
- First, configure the LED indicator settings (“Configuring LED indicator settings”). If you want to change these settings after you have configured the sensitivity of sensors, you must repeat the sensitivity configuration process.
Replace the cover.
Configuring LED indicator settings
Power off the detector (if it is powered on)
- Put a jumper across the LED pins.
- Power on the detector. The LED will start flashing purple to indicate the detector warm-up.
- Within 10 seconds from power on, remove the jumper from the LED pins to start the LED configuration mode. The LED will start flashing in the colour currently selected with the PIR potentiometer (the color does not have to be the same as that used so far for alarm/trouble indication by the LED).
- Use the PIR potentiometer to select a new color for alarm/trouble indication.
- Use the MW potentiometer to define whether the LED is to indicate motion detection by the microwave and PIR sensors:
- minimum position – indication disabled,
- maximum position – indication enabled.
- Put a jumper across the LED pins. The settings will be saved. The LED configuration mode will be terminated.
- If you do not put a jumper across the LED pins, the changes will not be saved and the LED configuration mode will end automatically after 20 minutes.
Start-up and walk test
The LED should be enabled during the walk test (see “LED indicator”). 1. Power on the detector. The LED will be flashing purple for 30 seconds to indicate the detector warm-up. 2. When the LED stops flashing, check that moving within the detector coverage area will make the LED turn on. Figure 10 shows the maximum coverage area of a detector installed at a height of 2.4 m.
Specifications
- Supply voltage -12 VDC ±15% Standby current consumption -10 mA Maximum current
- Consumption – 25 mA EOL resistors – 2 x 1.1 kW Outputs
- Alarm (NC relay, resistive load) – 40 mA / 24 VDC tamper (NC) – 100 mA / 30
- VDC Relay contact resistance (alarm output) – 26 Ω Microwave
- Frequency – 24.125 GHz 8 SLIM-DUAL-PET SATEL Detectable speed – 0.3…3 m/s Alarm signaling period – 2 s Warm-up
- Period – 30 s Recommended installation height – 2…2.4 m
- Coverage area – 12 m x 13 m, 90° Security grade according to EN 50131-2-4 –
- Grade 2 Compliance with standards – EN 50131-1, EN 50131-2-4, EN 50130-4, EN 50130 5 Environmental class according to EN 50130-5 – II
- Operating temperature range -10°C…+55°C Maximum humidity – 93±3% Dimensions – 62 x 137 x 42 mm
- Weight – 101 g