KEYENCE BT-A500 Series Handheld Terminal Instruction Manual

June 5, 2024
KEYENCE

Handheld Terminal
BT-A500 Series

Instruction Manual

Be sure to read this instruction manual carefully prior to operating this product. After reading, keep this manual in a safe place so that you can refer to it at any time.
In this instruction manual, BT-A500 Series means the BT-A500/A500G/A500GC/A500GM/A500GA/A500GE.

Symbols

The following symbols alert you to important messages. Be sure to read these messages carefully.

DANGER| Indicates a hazardous situation that, if not avoided, will result in death or serious injury.
---|---
WARNING| Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
CAUTION| Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
NOTICE| Indicates a situation that, if not avoided, could result in product damage as well as property damage.

Important Indicates cautions and limitations that must be followed during operation.
Paint Indicates additional information on proper operation.
Reference Indicates tips for better understanding of useful information.

  • IEEE802.11a/b/g/n/ac: Wireless LAN standards were established by the 802 committees which have designed standards of LAN technology in IEEE
    (Institute of Electrical and Electronics Engineers).

  • Bluetooth ® wordmark and logo belong to Bluetooth SIG, Inc. and KEYENCE uses them under license. Other trademarks or trade names belong to each owner.

  • Other company names or product names described in this manual are registered trademarks or trademarks of each company.

  • It is prohibited to use or copy all or any part of this manual without prior approval.

  • The information contained in this manual is subject to change without notice.

  • Android is a trademark of Google LLC.

  • Qualcomm is a trademark of Qualcomm Incorporated, registered in the U.S. and other countries.

  • Software information
    This product incorporates the software files developed independently by or for Keyence Corporation, software files owned and licensed by a third party, and software files subject to certain open source license agreements.
    The open-source software files are subject to the notices and additional terms and conditions.
    For information about such open-source software files, please refer to the information displayed on the following screen.
    Home → [Settings] → [System] → [About phone] → [Legal information] Such open- source software files are provided on an “AS IS” basis to the maximum extent permitted by applicable law.
    If there is any discrepancy between the terms and conditions of the applicable open source license agreement and the “License”, the terms and conditions of the applicable open source license agreement prevail with respect to the applicable open-source software.
    You may obtain a copy of the source code corresponding to the binaries for GPL/ LGPL-licensed file by sending a request to Keyence customer service at “soft-license@keyence.co.jp”. There will be a charge to cover the costs of providing the source code.

Safety Precautions on Laser Product

The BT-A500 Series uses a visible semiconductor laser as a light source. Follow the instructions mentioned in this manual. Otherwise, injury to the human body (eyes and skin) may result.

WARNING

Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

  • Do not disassemble this product. Laser emission from this product is not automatically stopped when it is disassembled. Class 2 Laser Product
  • Do not stare into the direct or specularly reflected beam.
  • Do not direct the beam at other people or into areas where other people unconnected with the laser work might be present.
  • Be careful of the path of the laser beam. If there is a possibility that the operator may be exposed to the specular or diffuse reflections, block the beam by installing a protective enclosure.
  • Install this product so that the path of the laser beam is not at the same height as that of the human eye.
  • BT-A500GA only
    Complies with 21 CFR 1040.10 and 1040.11 except for conformance with IEC 60825-1 Ed. 3., as described in Laser Notice No. 56, dated May 8, 2019.

The BT-A500 Series is classified as below in accordance with IEC60825-1.

Item| BT-A500/A500G/A500GC/ A500GM/A500GE|

BT-A500GA

---|---|---
Wavelength| 658 nm| 658 nm
Output| 1.0 mW| 1.0 mW
Laser class| • Class 2 laser product (IEC 60825-1)| Class 2 laser product (IEC60825-1, FDA(CDRH) Part 1040.10*)

  • The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of

Laser Notice No.56.

Locations of warning/explanation labels

KEYENCE BT-A500 Series Handheld Terminal - Scanner

Warning/explanation label

KEYENCE BT-A500 Series Handheld Terminal - label

Safety Precautions on LED Product

The degree of risk of this product is shown below.

• Risk group 2

  • LED product is classified as shown below according to IEC 62471.

    • Exempt Group
      Does not pose any photobiological hazard

    • Risk Group 1 (Low-Risk)
      Does not pose a hazard due to normal behavioral limitations on exposure.

    • Risk Group 2 (Moderate-Risk) Does not pose a hazard due to the aversion response to very bright light sources or due to thermal discomfort.

    • Risk Group 3 (High-Risk)
      May pose a hazard even for a momentary or brief exposure.

Follow the instructions mentioned in this manual. Otherwise, injury to the human body (eyes and skin) may result.

CAUTION
Possibly hazardous optical radiation emitted from this product. Do not stare at the operating lamp. May be harmful to the eyes.

Safety Precautions

• General cautions

DANGER

  • Do not use this product for the purpose of protecting a human body or a part of the human body.
  • This product is not intended for use as an explosion-proof product. Do not use this product in a hazardous location and/or potentially explosive atmosphere.
  • Do not use this product in an application that may cause death, serious injury or serious property damage due to a failure with this the product should occur, such as nuclear power plants, on aircraft, trains, ships, or vehicles, used within medical equipment, playground equipment, roller coasters, and other rides, etc.

WARNING

  • If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

CAUTION

  • Be sure to check that this product performs properly before starting the work or operation.
  • If this product malfunctions, take adequate safety precautions to prevent various types of damage.
  • Do not use this product in a manner not specified herein. It may result in fire, electric shock, or malfunction.

NOTICE

  • Do not modify this product or use it in any way other than described in the specifications. Otherwise, the functions and performance cannot be guaranteed.
  • The LCD panel may generate microscopic spots (black/bright spots), uneven brightness, or crosstalk (a phenomenon that which non-existent lines or patterns are displayed), depending on the conditions.
  • If the same display remains on the screen for a long time, an afterimage may occur due to the characteristics of LCD..

• Handling of BT-A500 Series

NOTICE

  • Use or store this product within the temperature range described in “Specifications” (5 page). Do not leave the product inside a closed car or in a place exposed to direct sunlight. Doing so may damage the unit or change its reading performance.
  • Use within the humidity range described in “Specifications” (5 pages). Do not use the product at locations where condensation occurs due to the rapid temperature change. Doing so may damage the unit or change its reading performance.
  • This is a precision instrument. Dropping this product or subjecting it to shock may cause damage. Be careful when carrying or using this unit.
  • Do not place the BT-A500 Series in a location with high humidity or a dusty area. Doing so may damage the unit or change its reading performance.
  • Please select a model that matches the country in which it will be used.
    For details, contact your nearest KEYENCE sales professional.

• Handling of BT-A500 Series main units

NOTICE
Do not insert a sharp object such as a needle into the buzzer hole on the backside of the BT-A500 Series. The tarpaulin may be damaged.

  Precautions when using the rechargeable battery pack (BT-B5)

WARNING

• Using batteries other than BT-B5 may cause fire or explosion. Be sure to use the specified battery.

NOTICE

  • Never use the rechargeable battery pack with devices other than those specified. If used with devices in which using conditions are different, the rechargeable battery pack may deteriorate earlier than expected or the devices may be damaged.
  • Use an AC power supply cord that coincides with the shape of the plug used in each country. Also, check that the cord is compliant with regulations and standards in each country.

Recycling the battery

Disposal methods of lithium-ion batteries differ among countries and regions. Follow the instructions in your area.
When disposing of lithium-ion batteries, the remaining capacity may cause heat generation, explosion, or fire due to contact with other metals. Be sure to cover the positive and negative terminals with adhesive insulation tape.

Precautions on regulations and Standards

Precautions on wireless LAN

WARNING

Remove the main battery of the BT-A500 Series near locations were using wireless devices is banned at medical institutions or near electric devices for medical purposes. Carry and use the product away from an implanted cardiac pacemaker.

Important

  • The BT-A500/A500G/A500GC/A500GM/A500GA/A500GE uses the radio waves of the 5 GHz band.
    The BT-A500/A500G can use the 5.2 GHz band (W52: 36, 40, 44, 48 ch), 5.3 GHz band (W53: 52, 56, 60, 64 ch), and 5.6 GHz band (W56: 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140 ch).
    The BT-A500GC can use the 5.2 GHz band (W52: 36, 40, 44, 48 ch), 5.3 GHz band (W53: 52, 56, 60, 64 ch), and 5.8 GHz band (W58: 149, 153, 157, 161, 165ch).
    The BT-A500GM can use the 5.2 GHz band (W52: 36, 40, 44, 48 ch), 5.3 GHz band (W53: 52, 56, 60, 64 ch), 5.6 GHz band (W56: 100, 104, 108, 112, 116, 120, 124, 128 ch) and 5.8 GHz (W58: 149, 153, 157, 161, 165ch).
    The BT-A500GA can use the 5.2 GHz band (W52: 36, 40, 44, 48 ch), 5.3 GHz band (W53: 52, 56, 60, 64 ch), 5.6 GHz band (W56: 100, 104, 108, 112, 116, 132, 136, 140 ch) and 5.8 GHz (W58: 149, 153, 157, 161, 165ch).
    The BT-A500GE can use the 5.2 GHz band (W52: 36, 40, 44, 48 ch), 5.3 GHz band (W53: 52, 56, 60, 64 ch), 5.6 GHz band (W56: 100, 104, 108, 112, 116, 120, 124, 128, 132, 136, 140 ch) and 5.8 GHz (W58: 149, 153, 157, 161, 165ch).
    Using 5.2 GHz band (W52) and 5.3 GHz band (W53) outdoors is prohibited by RadioAct.

  • Depending on the environment, communication may be impossible. Check the communication availability before using.

  • If this product is used near devices with the same frequency band, such as a wireless LAN device, microwave oven, heating equipment for industrial use, high-frequency equipment for medical use, etc., radio wave interference may occur and the communication speed will become slow or communication may become impossible.

  • If a wireless LAN and Bluetooth are used at the same time, radio wave interference may occur and the communication speed will become slow or communication may be interrupted. If there is a communication failure, stop using either the wireless LAN or Bluetooth.

  • Communication may be impossible at locations near metallic objects, locations surrounded by metallic walls, or where there is a lot of metallic powder.

  • With the frequency band for this unit, premise radio stations (license required), specified low power radio stations (license not required), and amateur radio stations (license required) for identifying mobile objects used for industrial, scientific, and medical equipment or factory production lines are operating.

  1. Before using this unit, be sure to check that premise radio stations, specified low power radio stations, and amateur radiostations for identifying mobile objects are not operating in the vicinity.
  2. If radio wave interference occurs from this unit against premise radio stations for identifying mobile objects, change the usable frequency immediately or stop the electric wave generation, and then contact the below phone number in regard to taking necessary measures (e.g. setting a partition) to avoid interference.
    [Thai] BT-A500/A500G only
    This telecommunication equipment is in compliance with NBTC requirements.
    [Singapore] A500/A500G/A500GM only
    This telecommunication equipment is in compliance with the regulatory requirement for Singapore.
    Complies with IMDA Standards DA104049

Precautions on Bluetooth

WARNING
Remove the main battery of the BT-A500 Series near locations were using wireless devices is banned at medical institutions or near electric devices for medical purposes. Carry and use the product away from an implanted cardiac pacemaker.

Important

  • Depending on the environment, communication may be impossible. Before starting the actual operation, be sure to test the operation.
  • If this product is used near devices with the same frequency band, such as a wireless LAN device, microwave oven, heating equipment for industrial use, high-frequency equipment for medical use, etc., radio wave interference may occur and the communication speed will become slow or communication may become impossible.
  • If a wireless LAN and Bluetooth are used at the same time, radio wave interference may occur and the communication speed will become slow or communication may be interrupted. If there is a communication failure, stop using either the wireless LAN or Bluetooth.
  • Communication may be impossible at locations near metallic objects, locations surrounded by metallic walls, or where there is a lot of metallic powder.
  • The possible communication distance is approx. 10 m of vision, however, even within 10 m, communication may become impossible depending on the environment. Check the communication availability before using.
  • With the frequency band for this unit, premise radio stations (license required), specified low power radio stations (license not required), and amateur radio stations (license required) for identifying mobile objects used for industrial, scientific, and medical equipment or factory production lines are operating.
    1. Before using this unit, be sure to check that premise radio stations, specified low power radio stations, and amateur radio stations for identifying mobile objects are not operating in the vicinity.
    2. If radio wave interference occurs from this unit against premise radio stations for identifying mobile objects, change the usable frequency immediately or stop the electric wave generation, and then contact the below phone number in regard to taking necessary measures (e.g. setting a partition) to avoid interference.
    [Thai] BT-A500/A500G only
    This telecommunication equipment is in compliance with NBTC requirements.
    [Singapore] BT-A500/A500G/A500GM only
    This telecommunication equipment is in compliance with the regulatory requirement for Singapore.
    Complies with IMDA Standards DA104049

FCC Regulations BT-A500GA only

  • This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions; (1) This device may not cause a harmful interface, and (2) this device must accept any interference received, including interference that may cause undesired operation.
  • Application regulation FCC Part 15 Subpart B Class A FCC Part 15 Subpart C FCC Part 15 Subpart E
  • The available scientific evidence does not show that any health problems are associated with using low-power wireless devices. There is no proof, however, that these low-power wireless devices are absolutely safe. Low power Wireless devices emit low levels of radiofrequency energy (RF) in the microwave range while being used. Whereas high levels of RF can produce health effects (by heating tissue), exposure of low-level RF that does not produce heating effects causes no known adverse health effects. Many studies of low-level RF exposures have not found any biological effects. Some studies have suggested that some biological effects might occur, but such findings have not been confirmed by additional research. The BT-A500GA has been tested and found to comply with FCC radiation exposure limits set forth for an uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines.
  • Compliance with FCC requirements Data transmission is always initiated by software, which is passed down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several special packets are initiated by the MAC. These are the only ways the digital baseband portion will turn on the RF transmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets is being transmitted. In other words, this device automatically discontinues transmission in case of either absence of information to transmit or operational failure.
  • 5.15-5.35GHz band is restricted to indoor operations only.
  • Frequency Tolerance: ±25ppm
  • Regulatory information page is located at: [settings] : [About phone] : [Regulatory]

CAUTION

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC.
Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense.

• FCC CAUTION
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
• This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter.

ISED Regulations BT-A500GA only

The BT-A500GA complies with the following regulations specified by the ISED.

  • Applicable regulation
    ICES-003
    RSS-247

  • The available scientific evidence does not show that any health problems are associated with using low-power wireless devices. There is no proof, however, that these low-power wireless devices are absolutely safe. Low power Wireless devices emit low levels of radiofrequency energy (RF) in the microwave range while being used. Whereas high levels of RF can produce health effects (by heating tissue), exposure to low-level RF that does not produce heating effects causes no known adverse health
    effects. Many studies of low-level RF exposures have not found any biological effects. Some studies have suggested that some biological effects might occur, but such
    findings have not been confirmed by additional research. The BT-A500GA has been tested and found to comply with IC radiation exposure limits set forth for an uncontrolled environment and meets RSS-102 of the IC radio frequency (RF) Exposure rules.

  • 5150-5350 MHz band is restricted to indoor operation only. High-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and these radars could cause interference and/or damage to LE-LAN devices.

  • Data transmission is always initiated by software, which is passed down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several
    special packets are initiated by the MAC. These are the only ways the digital baseband portion will turn on the RF transmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets is being transmitted. In other words, this device automatically discontinues transmission in case of either absence of information to transmit or operational failure.

CAUTION

  • This device complies with Industry Canada’s license-exempt RSS. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

• UL certification BT-A500GA only
The BT-A500GA complies with the following UL/CSA standards and has obtained the UL/ C-UL certifications.

  • Applicable standards UL 62368-1
    CAN/CSA-C22.2 No. 62368-1

  • UL File No. E167973

  • UL category AZOT/AZOT7

CAUTION

RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE.
DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.

CE Marking BT-A500GE only
KEYENCE Corporation has confirmed that this product complies with the essential requirements of the applicable EU Directive(s), based on the following specifications.
Be sure to consider the following specifications when using this product in the Member States of the European Union.

  • RE Directive
  • RoHS Directive

The full text of the EU declaration of conformity is available at the following internet address: http://www.keyence.com/cedoc

  • Frequency band of operation: Maximum radio-frequency power

2400 ~ 2483.5 MHz: 19.54 dBm (89.85 mW)
5180 ~ 5320 MHz: 22.98 dBm (198.61 mW)
These specifications do not give any guarantee that the end-product with this product incorporated complies with the essential requirements of RE and Machinery Directive.
The manufacturer of the end-product is solely responsible for the compliance of the end-product itself according to these Directives.
The device is restricted to indoor use only when operating in the 5150 to 5350 MHz frequency range.

AT BE BG HR CY CZ DK
EE FI FR DE EL HU IE
IT LV LT LU MT NL PL
PT RO SK SI ES SE UK
IS LI NO CH TR

Explanation of symbols

DC Mark

This symbol indicates a direct current.

Stand-by Mark

This symbol indicates a standby condition.

WEEK

This symbol indicates a separate collection for WEEE.

Precautions for proper use

NOTICE

• Handling of packing

  • The BT-A500 Series has an enclosure rating of IP65, however, if the “battery attachment cover” is not properly attached, these enclosure ratings cannot be guaranteed. When using in environments where water or dust is present, check if these are properly attached.
  • Dropping the BT-A500 Series or subjecting it to extreme shock may lead to the loss of water-proofing.

Cleaning

Clean the following parts with air blow periodically.
If removing dirt is difficult, use a cotton swab to clean the contacts directly. (Use absolute ethanol if dirt is stuck on them.)
Remove the battery attachment cover before cleaning the battery contact.

KEYENCE BT-A500 Series Handheld Terminal - Battery

NOTICE

If dirt or dust is attached, contact failure may occur on the battery/ charging/communication contacts. This may cause the charging function to deteriorate and instantaneous interruption.
Make sure that waste textile is not attached to the battery/charging/ communication contacts when cleaning.

Checking the Package

When opening the package, check the following items are all included.
If there is something missing, product failure, or damage, contact your nearest KEYENCE sales office.

BT-A500/A500G/A500GC/A500GM/A500GA/A500GE

KEYENCE BT-A500 Series Handheld Terminal - bt

Specifications

Item Specifications
Model BT-A500/A500G/A500GC/ A500GM/A500GA/A500GE
Controller CPU
OS Android™ 10
Main memory RAM
ROM 16GB
Display LCD
Resolution (number of dots) 320 (H) x 480 (V)
Operation confirmation LED 3-color LED (red, green, blue, yellow, cyan,

magenta, white)
Operations| Hard keys| Type| Set of arrow keys x 1 (4 directions), trigger keys x 3 (center x 1, side x 2), customized keys x 2 (P1 key, P2 key), function change keys x 4 (white key, orange key, blue key, SFT key), data input keys x 14 (0 to 9 keys, ENT key, clear key, symbol key, minus key), power key x 1
Touch panel| Electrostatic capacitance method (Dragontrail tempered glass)
Scanner| Optical characteristic| Reading light source| High-intensity white LED
Pointer light source| Visible light semiconductor laser (658 nm) Output 1.0 mW Class 2 laser product (IEC 60825-1)
Minimum resolution| 2D code: 0.191mm Barcode: 0.127mm
Reading distance| 80-1550mm
(CODE39 narrow bar width 0.254mm) 25-4100mm
(CODE39 narrow bar width 0.508mm) 100-370mm
(QR cell size 0.254mm) 0-1200mm
(QR cell size 0.508mm)2
Reading width/ Field range| 151x94mm (Reading distance 300mm 1ft)
2
Supported codes| JAN/EAN/UPC (add-on code supported), CODE128, GS1-128, CODE39, NW-7, CODE93, ITF COOP2of5, Industrial 2of5 QR code,
Micro QR, DataMatrix (ECC200), PDF417, GS1 DataBar, composite symbol, Postal
Wireless communication| Wireless LAN| Wireless standards| IEEE802.11a/b/g/n/ac
Radiofrequency| BT-A500/A500G:
2.4GHz (b, g, n:1 to 13ch) 5.2GHz, 5.3GHz, 5.6GHz (a/n/ac) BT-A500GC: 2.4GHz (b, g, n:1 to 13ch) 5.2GHz, 5.3GHz, 5.8GHz (a/n/ac) BT-A500GM/A500GE:
2.4GHz (b, g, n:1 to 13ch)
5.2GHz, 5.3GHz, 5.6GHz, 5.8GHz (a/n/ac) BT-A500GA: 2.4GHz (b, g, n: 1 to 11ch)
5.2GHz, 5.3GHz, 5.6GHz, 5.8GHz (a/n/ac)

  • W52/W53 can only be used indoors.
    Security method| Security:
    OPEN / WEP(64/128 bit)/ WPA/WPA2/ WPA3 WPA encryption: TKIP/ AES Authentication: PSK/ PEAP/ EAP-TLS/ EAP-TTLS/ EAP-PWD
    Bluetooth®| Wireless standards| Bluetooth® V5.0 + BR/EDR/LE
    Supported profiles| A2DP, AVRCP, HID, IOPT, OPP, PAN, SPP
    Communication distance| Approx. 10 m
    Item| Specifications
    ---|---
    Power supply| Main battery| Type| Dedicated lithium-ion battery pack
    Capacity| 3250 mAh
    Charging time| Approx. 6.0 hours (ambient temperature)
    Backup battery| RAM data| Electric double-layer capacitor 3 minutes 12
    Others| Audio| Speaker, Microphone
    Vibration| Available
    Camera| 13MP, autofocus
    Sensor| Accelerometer, Ambient Light, Gyroscope
    USB| USB Type-C port
    Environmental resistance| Enclosure rating| IP65
    Drop resistance (from a height)| Onto concrete from a height of 1.8 m Up to 20,000 impacts from a height of 30 cm 2
    Ambient operating temperature| -20 to +50°C (no freezing)
    3 When charging 0 to +40ºC
    Ambient operating humidity| 20 to 85% RH (no condensation)
    Ambient storage temperature| -20 to +70°C (no freezing)
    Ambient storage humidity| 20 to 85% RH (no condensation)
    Dimensions| 88mm x 134mm x 235mm
    Weight| Approx. 265 g (with battery pack)

1 When the main battery is not attached or has no remaining charge.
2 This is a test value, and the value is not guaranteed.
*3 Continuous usage time may be shortened significantly in a subfreezing environment due to a load. Be sure to conduct a test before use.

Outline dimensional drawing

KEYENCE BT-A500 Series Handheld Terminal - drawing

WARRANTIES AND DISCLAIMERS

(1) KEYENCE warrants the Products to be free of defects in materials and workmanship for a period of one (1) year from the date of shipment. If any models or samples were shown to the Buyer, such models or samples were used merely to illustrate the general type and quality of the Products and not to represent that the Products would necessarily conform to said models or samples. Any Products found to be defective must be shipped to KEYENCE with all shipping costs paid by the Buyer or offered to KEYENCE for inspection and examination. Upon examination by KEYENCE, KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at no charge any Products found to be defective. This warranty does not apply to any defects resulting from any action of the Buyer, including but not limited to improper installation, improper interfacing, improper repair, unauthorized modification, misapplication, and mishandling, such as exposure to excessive current, heat, coldness, moisture, vibration or outdoors air. Components that wear are not warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are only suggestions, and it is Buyer’s responsibility to ascertain the fitness of the  Products for the Buyer’s intended use. KEYENCE will not be responsible for any damages that may result from the use of the Products.
(3) The Products and any samples (“Products/Samples”) supplied to the Buyer are not to be used internally in humans, for human transportation, as safety devices or fail-safe systems, unless their written specifications state otherwise. Should any Products/ Samples be used in such a manner or misused in any way, KEYENCE assumes no responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE harmless from any liability or damage whatsoever arising out of any misuse of the  Products/Samples.
(4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS,
IMPLIED, AND STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON- INFRINGEMENT OF PROPRIETARY RIGHTS, ARE EXPRESSLY DISCLAIMED.
IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA, LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR ANY OTHER CLAIM AGAINST BUYER.

In some jurisdictions, some of the foregoing warranty disclaimers or damage limitations may not apply.

BUYER’S TRANSFER OBLIGATIONS:
If the Products/Samples purchased by the Buyer are to be resold or delivered to a third party, the Buyer must provide such a third party with a copy of this document, all specifications, manuals, catalogs, leaflets, and written information provided to the Buyer pertaining to the Products/Samples.

KEYENCE CORPORATION
1-3-14, Higashi-Nakajima, Higashi-Yodogawa-ku, Osaka, 533-8555, Japan
PHONE: +81-6-6379-2211
www.keyence.com/glb

AUSTRIA
Ph: +43 2236 378266 0
BELGIUM
Ph: +32 15 281 222
BRAZIL
Ph: +55-11-3045-4011
CANADA
Ph: +1-905-366-7655
CHINA
Ph: +86-21-3357-1001
CZECH REPUBLIC
Ph: +420 220 184 700
FRANCE
Ph: +33-1-56-37-78-00
GERMANY
Ph: +49-6102-3689-0HONG KONG
Ph: +852-3104-1010
HUNGARY
Ph: +36 1 802 7360| INDIA
Ph: +91-44-4963-0900
INDONESIA
Ph: +62-21-2966-0120
ITALY
Ph: +39-02-6688220
KOREA
Ph: +82-31-789-4300
MALAYSIA
Ph: +60-3-7883-2211
MEXICO
Ph: +52-55-8850-0100UK & IRELAND
Ph: +44 1908-696-900
USA
Ph: +1-201-930-0100
VIETNAM
Ph: +84-24-3772-5555| NETHERLANDS
Ph: +31 40 20 66 100
PHILIPPINES
Ph: +63-2-8981-5000
POLAND
Ph: +48 71 36861 60
ROMANIA
Ph: +40 269 232 808
SINGAPORE
Ph: +65-6392-1011
SLOVAKIA
Ph: +421 2 5939 6461
SLOVENIA
Ph: +386 1 4701 666
SWITZERLAND
Ph: +41 43 455 77 30TAIWAN
Ph: +886-2-2721-8080
THAILAND
Ph: +66-2-369-2777
---|---|---

Specifications are subject to change without notice.
Copyright (c) 2020 KEYENCE CORPORATION.
All rights reserved.
15984GB 1099-1 96M15984 Printed in Japan

A6WW1-MAN-2010

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals