globe 26180 Disinfectant Under Cabinet Light Strip Installation Guide

June 5, 2024
globe

globe 26180 Disinfectant Under Cabinet Light Strip

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Product

DISINFECTION STRIP LIGHT

Thank you for selecting Globe as your lighting choice for your home. With proper care, this product will provide years of pleasure and enjoyment. Carefully follow the instructions in order to ensure that this product functions safely and properly for years to come.

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Fig1

SAVE THESE INSTRUCTIONS READ ALL INSTRUCTIONS

CAUTION

  • Read and understand all Safety and Operating instructions in this manual before attempting to use this product.
  • Since 1932, Globe has taken pride in offering products of the highest quality, and a level of service unparalleled in the industry. Should you encounter any difficulties, have any questions or simply wish to offer us your valuable feedback, you may contact us in the following ways
  • Toll-Free Telephone: 1-888-543-1388 (North America Only) / Toll-Free Fax: 1-800-668-4562 (North America Only) E-Mail: info@globe-electric.com / Mail: Globe Electric Customer Service Department 150 Oneida, Montreal,
  • Quebec, Canada H9R 1A8
  • Please visit our website to discover other quality Globe products: http://www.globe-electric.com

INTRODUCTION TO UV TECHNOLOGY

The sun produces a broad spectrum of light, including a portion invisible to the human eye called Ultraviolet. This ultraviolet light has a wavelength shorter than that of visible light and is generally subdivided into UV-A, UV-B, and UV-C. While Near-UV is not technically within the ultraviolet spectrum, it shares certain useful germicidal properties. Short-wave ultraviolet light, such as UV-C (100nm to 280nm), damages DNA and disinfects surfaces with which it comes into contact. Fortunately for us, the sun’s UV-C light is absorbed by the earth’s Ozone layer, protecting us from its harmful effects.

Man-made UV-C technology was developed to harness the sanitizing/germicidal properties of UVC and has been around for over 100 years. UV-C Light destroys the ability of bacteria and germs to multiply by damaging their DNA structures and deactivating their reproductive capabilities. Our products allow our customers to use these potent effects to their advantage by targeting and neutralizing germs and bacteria. Not only is this method cost saving for consumers but when operated correctly, UV-C Light can kill up to 99% of germs and bacteria, such as Salmonella, Escherichia Coli, Staphylococcus aureus, and Influenza Virus A H3N2. This also includes reducing odors caused by bacteria. The next generation of clean provides a no-contact chemical-free approach that is environmentally friendly, reusable, and sustainable.

SAFETY PRECAUTIONS

READ AND SAVE ALL INSTRUCTIONS

To ensure the safety and proper usage of this product, please consult this instruction manual before initial use. Even with built-in safety features, it is important to handle all UV Light devices with care, using only as directed, and closely following the provided instructions for each product. Improper use of this light can result in injury. Follow all safeguards stated in this manual in addition to normal safety precautions when working with electrical devices. DO NOT attempt to service this device.

DO NOT ALLOW ANY EXPOSURE TO THE ULTRAVIOLET LIGHT TO

  • Keep devices away from children and pets
  • Do not drop the device.
  • Do not look directly into the UV light source.
  • May damage certain fabrics or materials and exposure may cause paint to fade over time.
  • Ensure that the device is used only for its intended purpose; cleaning keyboards, tablet, infant accessories, mobile phones, toilet seats, doorknobs, cutting boards, kitchen utensils and other required surfaces or materials. Refrain from operating the device if it has been damaged.
  • globe-26180-Disinfectant-Under-Cabinet-Light-Strip-Fig27. Do not use the product if there is any sign of battery leakage as it may cause damage to the strip light.
  • Allows allowing the product to cool down completely before storing. When not in use, remove batteries and store them in a provided travel bag. Store in a safe place, out of reach of children.

DANGER

  1. DO NOT ALLOW THIS PRODUCT TO BE EXPOSED TO WATER OR ANY OTHER TYPE OF LIQUID OR EXCESSIVE MOISTURE.
  2. Always direct the UV-C light AWAY from the eyes and skin. Direct prolonged exposure of eyes or skin to The UV-C light bulb can cause serious skin burn and eye inflammation from short wave ultraviolet radiation. Radiation from these lamps is harmful to the eyes and skin.
  3. Application of UV-C light to existing mold growth can cause respiratory irritation and allergic symptoms. Do not use UV-C light where active mold growth exists. Remove active mold growth from surfaces prior to exposure.

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this devised must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and has been found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna
  • Increase the separation between the equipment and receiver
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

TECHNICAL DATA

  1. Model: 26180
  2. UV-C LED Technology: 270-280nm UV-A LED Technology: 352.6nm
  3. Built-in Rechargeable 3.7v/1200mah lithium battery
  4. Power: 4 W
  5. Life Span: 10 000 hours
  6. Built-in motion sensor (10-12 ft)
  7. 120 Lumens
  8. ON/OFF/AUTO Button
  9. Micro-USB cable included (19.7 inches)
  10. Magnetic strip and 2x screws included

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Fig3

TO MAXIMIZE THE EFFECTIVENESS OF YOUR UVC DEVICE

bacteria; Staphylococcus Aureus (ATCC6538), Escherichia Coli (8099), Salmonella Typhimurium (ATCC14028), and the Influenza Virus A H3N2. To increase the level of neutralization, place the light over the item/surface at the minimum recommended distance for a longer period. Products will still be effective when distance is increased but will require a longer exposure to the UV light to neutralize germs. When used as directed, the following results will be obtained at the given distance and time:

Optimal Use

For maximum disinfection (over 99%), the light should be positioned at 6 inches away from the surface for one 15-minute cycle for bacteria or positioned at 3 inches for one 15-minute cycle for influenza.

Optional Use (recommended for bacteria only)

When the light is positioned at 24 inches we recommend running three 15-minute cycles, the percentage of antibacterial neutralization should reach over 70%. For greater disinfection rates at this distance, please run additional cycles

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Fig4

RECHARGING THE STRIP LIGHT

RECHARGEABLE BATTERY

  • Remove the base of the device by pulling downwards. To show access to the charging port.

  • To check the battery level, press the “check button”. Green lights will indicate the level of charging remaining.
    To charge the strip light, plug the included Micro-USB charging cable into a USB-A 1A adapter.

  • Then insert the USB charging cable into the charging port. When the cable is properly connected, charging starts automatically. The battery level indicator lights will blink while charging, and all four lights will be green when charging is fully complete.

  • When light is not being used for disinfection purposes, please switch the function to On or Off mode to conserve battery life.

  • Be sure to use the included USB charging cable as other cables may cause damage to the product. Depending on the type of the device, charging from the USB port of general electrical products (such as a PC) can cause the product to no longer function.

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Fig5

INSTALLATION INSTRUCTIONS

Check the surrounding location of where you would like to place the light and ensure that it is clear of debris or dust. In order to activate the motion sensor, the light needs to be placed in a dark area.

OPTION 1 Mounting with 3M magnetic strip (included)

  • Remove the plastic covering on one side of tape
  • Place tape in the rectangular recessed area on the base of the light
  • Remove the plastic covering on the stick side of the tape
  • Place the light in the desired location. Press firmly for 5 seconds so that the tape adheres to surface
  • Be cautious of what surface the double sided tape is attached to, as it may remove paint or damage surfaces.

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Fig6

OPTION 2: Mounting with screws (included)

  • Measure two holes 7.87 inches (20cm) a part in the desired mounting area
  • Screw in the screws based on your measurements to the desired mounting area
  • Once the screws are in place, align the two holes on the back of light with the two screws
  • Slide the light to the left to secure it in place

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Fig7

LIGHT POSITIONING

  • Place the light in a dark space to activate the motion sensor
  • The light will not function if it is placed in a well-lit area
  • The motion detection range has a angel of 120 degrees
  • Motion can be detected up to 10-12 ft away

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Fig8

OPERATING DIRECTIONS

  • WARNING

  • Please follow the below instructions carefully to ensure the proper use of your device. This light will only function in a dark space.
    SAFETY FEATURES

  • In order to prevent the eyes from being exposed to the UV light, the light is designed with a built-in sensor that will automatically turn off the UV light and switch to regular light when motion is detected when the UV light is on. This feature permits the light to only have the UV light on when there is no motion in the surrounding area.
    NOTICE

  • To maximize the effectiveness of the product, surfaces should be relatively clean and free of grime, dust, and other materials that will prevent the germs from being directly exposed to UV-C Light.
    THE ON/OFF/AUTO SWITCH IS LOCATED ON THE SIDE OF THE LIGHT

  • AUTO (Motion + Regular Light + UV Light)

  • Place switch to AUTO mode and the normal light will appear for 20 seconds

  • If no motion is detected within those 20 seconds, the UV light will turn on automatically for 15 minutes

  • If the motion is detected while the UV light is on, the UV light will change to regular light.

ON (Motion + Regular Light)

  • Place switch to ON
  • If the motion is detected the normal light will turn on
  • If no motion is detected, the light will turn off after 20 seconds
  • OFF
  • When switched to OFF, the light will be powered off from all functions

globe-26180-Disinfectant-Under-Cabinet-Light-Strip-
Fig9

CARE AND MAINTENANCE

Your UV-C Disinfection Strip Light requires the following care and maintenance:
WARNING
Never use detergents, gasoline, furniture polish, or any other household cleaning product to clean any part of the device.
CLEANING
Use a dry and soft cloth to wipe the device if needed.
STORAGE
Allows allowing the product to cool down completely before storing. When not in use, store in a safe place out of reach of children.

WARRANTY

LIMITED WARRANTY For a period of 1-year from the date of purchase, in case of malfunction caused by defects in material or workmanship, the product will be repaired or replaced at no charge to you. Return the product prepaid to Globe Electric Company Inc. Globe reserves the right to repair or replace at any option. Warranty begins on the purchase date of the consumer. You must supply a copy of your dated cash register receipt when you request warranty service. Repair or replacement as described above, shall be no liability on the part of Globe for any special, indirect, incidental, or consequential damages, including but not limited to any loss of business or profits whether foreseeable or not. Some jurisdictions may not all the exclusion of incidental consequential damages, so the above limitation or exclusion may not apply to you. For warranty-related issues, please contact Globe Electric Customer Support by email at info@globe-electric.com or by phone at 1-888-543-1388.

ADDITIONAL SUPPORT

Please see our website to learn more about UV technology or for any further directional use of any products in the Globe Electric UV assortment line. globe-electric.com/en/uv-light/

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

globe User Manuals

Related Manuals