CHAUVET DJ SlimPAR 64 LED PAR Wash Light User Guide

June 5, 2024
Chauvet DJ

CHAUVET DJ SlimPAR 64 LED PAR Wash Light

CHAUVET-DJ-SlimPAR-64-LED-PAR-Wash-Light-product

About This Guide
The SlimPAR 64 Quick Reference Guide (QRG) has basic product information such as mounting, menu options, and DMX values. Download the User Manual from www.chauvetdj.com for more details.
Disclaimer: The information and specifications contained in this QRG are subject to change without notice.

LIMITED WARRANTY

FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE. For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.
For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www. Chauvet lighting.eu /warranty-registration.
Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.

Safety Notes

These Safety Notes include important information about installation, use, and maintenance.

  • ONLY connect this product to a grounded and protected circuit.
  • DISCONNECT from power before cleaning or replacing the fuse.
  • DO NOT look at the light source when the product is on.
  • Make sure the power cord is not crimped or damaged.
  • Never disconnect this product from power by pulling on the cord.
  • When mounting this product overhead, ALWAYS use a safety cable.
  • DO NOT allow flammable materials close to the product when it is operating.
  • DO NOT touch the product’s housing when it is on because it will be hot.
  • The voltage of the outlet to which you are connecting this product must be within the range stated on the decal or rear panel of the product.
  • This product is for indoor use only! (IP20) To prevent risk of fire or shock, do not expose this product to rain or moisture.
  • Always mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
  • Be sure that no ventilation slots on the unit’s housing are blocked.
  • Never connect this product to a dimmer or rheostat.
  • Replace the fuse with the same type and rating.
  • Never carry the product by the power cord. Use only the hanging bracket or handle to carry this product.
  • The maximum ambient temperature is 104 °F (40 °C). Do not operate this product at higher temperatures.
  • In the event of a serious operating problem, stop using immediately.
  • DO NOT open this product. It contains no user-serviceable parts.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Contact
Outside the U.S., United Kingdom, Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or return a product. Refer to Contact Us at the end of this QRG for contact information.
What is Included

  • SlimPAR 64
  • Power Cord
  • Quick Reference Guide

To Begin
Unpack your SlimPAR 64 and make sure you have received all parts in good condition. If the box or contents appear damaged, notify the carrier immediately, not Chauvet.

AC Power
This product has an auto-ranging power supply that works with an input voltage range of 100 to 240 VAC, 50/60 Hz. To eliminate wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.

Power Linking
For the maximum number of SlimPAR 64 products that you can power link at each voltage, see the User Manual or the sticker on the product.
Fuse Replacement

  1. Disconnect the product from power.
  2. Wedge the tip of a flat-head screwdriver into the slot of the fuse holder.
  3. Pry the safety cap out of the housing.
  4. Remove the blown fuse from the clip on the front of the safety cap and replace with a fuse of the exact same type and rating.
  5. Re-insert the fuse holder and reconnect power.

Mounting

Before mounting this product, read the Safety Notes.
Mounting Diagram

Control Panel Description

Button Function
< MENU> Exits from the current menu or function
< UP> Navigates upwards through the menu list and increases the numeric

value when in a function
< DOWN>| Navigates downwards through the menu list and decreases the numeric value when in a function
< ENTER>| Enables the currently displayed menu or sets the currently selected value into the selected function
Mode| Programming Levels| Description
---|---|---
DMX Mode| 3-CH| d 1–510| 3-channel DMX mode
7-CH| d 1–506| 7-channel DMX mode
Static Colors| C–| C 1–7| Static colors
Programs| P–| P 1–4| Automatic programs
P 5–6| Sound-active programs
Auto Speed| S–| S 1–100| Program speed for P 1–4
Sensitivity| SEnS| U 1–100| Sound sensitivity for P 5–6
Custom Color Mixing| ****

U–

| r 0–255| Custom static colors Combine red, green, and blue
g 0–255
b 0–255

DMX Linking
The SlimPAR 64 can work with a DMX controller. Instructions for connecting and configuring this product for DMX operation are in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com.

Starting Address
To ensure full access to all channels available in each DMX mode, the highest recommended DMX address is 506.

Master/Slave Connection
The SlimPAR 64 uses the DMX data connection for its Master/Slave mode. Information about configuring the SlimPAR 64 for Master/Slave operation is in the User Manual, which is available from the Chauvet website.

DMX Values

Channel Function Value Percent/Setting
1 Red 000 ó 255 0–100%
2 Green 000 ó 255 0–100%
3 Blue 000 ó 255 0–100%
4 Color Macros 000 ó 015 No function
016 ó 255 Color macros


5

| Strobe

(when Ch. 6 is 000 ó 031)

| 000 ó 015| No function
016 ó 255| Strobe, slow to fast
Auto Speed

(when Ch. 6 is 032 ó 223)

| 000 ó 255| Auto program speed, slow to fast
Sound Sensitivity

(when Ch. 6 is 224 ó 255)

| 000 ó 010| Sound sensitivity Off
011 ó 255| Sound sensitivity, low to high




6

| ****



Automatic Programs/ Sound-Active Mode

| 000 ó 031| No function
032 ó 063| Pulse effect, 0–100%
064 ó 095| Pulse effect, 100–0%
096 ó 127| Pulse effect, 0–100–0%
128 ó 159| Auto fade transition
160 ó 191| Auto snap transition (3-color)
192 ó 223| Auto snap transition (7-color)
224 ó 255| Sound-active mode
7| Dimmer| 000 ó 255| 0–100%
Channel| Function| Value| Percent/Setting
---|---|---|---
1| Red| 000 ó 255| 0–100%
2| Green| 000 ó 255| 0–100%
3| Blue| 000 ó 255| 0–100%

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Chauvet DJ User Manuals

Related Manuals