INSTALLATION AND SAFETY INSTRUCTIONS
IMPORTANT: Read before installing the fixture. Retain for future reference.
WARNING: Risk of Fire or Electric Shock
-
Disconnect power before installation or any maintenance of the fixture.
-
To avoid damage, falling, electric shock or fire, do not modify the fixture or replace accessories without confirming with the supplier first.
Only authorized, qualified personnel should install this fixture and should follow the owner’s manual. -
Do not dismantle the fixture without the supplier’s authorization.
-
Do not touch the power supply when the fixture is operating.
-
For use in environments where an accumulation of non-conductive dust on the fixture may be expected.
-
Suitable for indoor/outdoor installations.
-
As per UL STD 1598: The volume of a wiring compartment or junction box with more then one conduit or cable entry shall be calculated using two 12AWG branch circuit conductors entering, and two 12AWG branch circuit conductors leaving, and two 12AW insulated grounding conductors.
Fixture Includes:
1 LED Lamp
1 Junction Box
IMPORTANT: This product must be installed in accordance with the
applicable installation code by a person familiar with the construction and
operation of the product and the
hazards involved.
WIRING DIAGRAM
Model| Dimensions| Watts| Volts| CCT| CRI|
Finish
---|---|---|---|---|---|---
S11826| 4 inches| 10W|
120V
| 27K,30K,35K,40K,50K|
90
|
White
S11827| 6 inches| 12W| 27K,30K,35K,40K,50K
S11828| 8 inches| 24W| 27K,30K,35K,40K,50K
INSTALLATION
TOOLS REQUIRED: Hole saw, measuring tape and connector cables (as needed). NOTE: Use extensions if necessary. Available connector cables are 6′ (1.8m). Connector cables are linkable.
- Turn power OFF from the electrical panel before starting installation.
- Cut a hole in the ceiling for the downlight in a suitable position. Refer to Hole Cut Dimension chart (below).
- Run the electrical wire from the switch (power supply wire) through the mounting hole. Use NMD90 Romex or BX cable. See Figure A.
- Open the Junction Box swing cover and remove the appropriate knockouts.
- I nsert the power supply wire through the knockout and fasten with a cable connector (not included).
- Connect wires inside the Junction Box using the quick-connect terminals. Connect green ground with the green box wire. Connect the black and white power leads with the matching black and white box wires. See Wiring Diagram.
- Put all wires and connections back into the box and close the cover securely.
- New Construction Applications : Junction Box shall be firmly secured to the studs, joists or similar fixed structural units. Remodel Applications: Do not require the Junction Box to be firmly secured to fixed structural units. Remove the Junction Box tabs, then insert into the ceiling.
- Choose desired color temperature. See figure B.
- Bend back the two torsion springs and slowly fit the fixture through the ceiling hole. The torsion springs will pull the fixture into place. See Figures C & D.
- Once installation is complete, turn power ON to confirm the fixture is working properly.
Hole Cut Dimensions:
- 4″ fixture = ø 4 3/16″ (106mm)
- 6″ fixture = ø 6 3/16″ (157mm)