STIEBEL ELTRON SBP 100 Classic Heating Buffer Cylinder Instruction Manual
- June 5, 2024
- STIEBEL ELTRON
Table of Contents
SBP 100 Classic Heating Buffer Cylinder
Instruction Manual
OPERATION
1. General information
The chapter “Operation” is intended for appliance users and qualified
contractors.
The chapter “Installation” is intended for qualified contractors.
Note Read these instructions carefully before using the appliance and
retain them for future reference. Pass on the instructions to a new user if
required.
Safety instructions
1.1.1 Structure of safety instructions
KEYWORD Type of risk Here, possible consequences are listed that may result
from failure to observe the safety instructions.
Steps to prevent the risk are listed.
1.1.2 Symbols, type of risk
Symbol | Type of risk |
---|---|
**** | Burns (burns, scalding) |
1.1.3 Keywords
KEYWORD | Meaning |
---|---|
DANGER | Failure to observe this information will result in serious injury or |
death.
WARNING| Failure to observe this information may result in serious injury or
death.
CAUTION| Failure to observe this information may result in non-serious or
minor injury.
1.2 Other symbols in this documentation
Note
General information is identified by the adjacent symbol. f Read these texts
carefully.
Symbol | Meaning |
---|---|
**** | Material losses (appliance damage, consequential losses and |
environmental pollution)
| Appliance disposal
This symbol indicates that you have to do something. The action you need to
take is described step by step.
1.3 Information on the appliance
Connections
Symbol | Meaning |
---|---|
Supply / Inlet / Flow | |
Drain / Outlet / Return | |
Heat pump | |
Central heating |
1.4 Units of measurement
Note All measurements are given in mm unless stated otherwise.
Safety
2.1 Intended use
This appliance is designed to extend the operating time of the heat generator
and to bridge power-OFF periods. The heat pump buffer cylinder also provides
hydraulic separation of the flow rates in the heat pump circuit and the
heating circuit.
Observation of these instructions and of instructions for any accessories and
other system components used is also part of the correct use of this
appliance.
Any other use beyond that described shall be deemed inappropriate. Using the
appliance for heating fluids other than water or for water supplemented with
chemicals, such as brine, is also deemed inappropriate.
Appliance description
The steel cylinder with directly applied foam insulation is equipped with a protective cover, connections for ventilation and draining, and a sensor pipe. The hydraulic connections are routed through the top.
Troubleshooting
Call your qualified contractor.
To facilitate and speed up your inquiry, please provide the serial number from
the type plate (000000-0000-000000):
Safety
Only a qualified contractor should carry out the installation, commissioning,
maintenance and repair of the appliance.
5.1 General safety instructions
We guarantee trouble-free function and operational reliability only if
original accessories and spare parts intended for the appliance are used.
5.2 Instructions, standards, and regulations
Note Observe all applicable national and regional regulations and
instructions.
Appliance description
6.1 Standard delivery
The following are delivered with the appliance: – 3 adjustable feet
Preparations
7.1 Installation site
- Always install the appliance in a room free from the risk of frost.
- Ensure the floor has sufficient load-bearing capacity and evenness (see chapter “Specification / Data table”).
- Observe the room height and height when tilted (see chapter “Specification / Data table”).
Minimum clearances
Installation
8.1 Positioning the equipment
Use the adjustable feet provided to compensate for any unevenness in the
floor.
- Undo the 3 screws from the non-returnable pallet.
- Tilt the appliance and screw the 3 adjustable feet provided into the appliance.
- Lift the appliance off the pallet.
- When installing, observe minimum clearances (see chapter “Preparations / Installation site”).
8.2 Heating water connection
Material losses
Carry out all water connection and installation work in accordance with
regulations.
- Observe the heat pump operating and installation instructions when making the heating water connection.
- Connect the hydraulic connections with flat gaskets.
Oxygen diffusion
**Material losses
Avoid open heating systems and plastic pipes in underfloor heating systems
which are permeable to oxygen.
In underfloor heating systems with plastic pipes that are permeable to oxygen
and in open vented heating systems, oxygen diffusion may lead to corrosion on
the steel components of the heating system (e.g. on the indirect coil of the
DHW cylinder, on buffer cylinders, steel heating elements or steel pipes).
Material losses**
The products of corrosion (e.g. rusty sludge) can settle in the heating system
components and can result in a lower output or fault shutdowns due to reduced
cross-sections.
Commissioning
9.1 Initial start-up
- Fill and bleed the appliance (see chapter “Specification / Dimensions and connections”).
- Carry out a tightness check.
9.1.1 Appliance handover
- Explain the function of the appliance to users and familiarise them with its operation.
- Make the user aware of potential dangers, especially the risk of scalding.
- Hand over these instructions
9.2 Recommissioning
See chapter “Commissioning / Initial start-up”.
10. Shutdown
f Drain the appliance. See chapter “Maintenance / Draining the appliance”.
11. Maintenance
No special maintenance is required for the appliance. A regular visual check
is sufficient.
11.1 Draining the appliance
WARNING Burns Hot water may escape during draining.
If the appliance needs to be drained for maintenance or to protect the whole
installation when there is a risk of frost, proceed as follows:
Drain the appliance using the appliance drain connection (see chapter
“Specification / Dimensions and connections”).
www.stiebel-eltron.com
Specification
12.1 Dimensions and connections
| | | SBP 100 classic
---|---|---|---
d03| Heat pump flow optional| Male thread| G 1 1/4
d04| Heat pump return optional| Male thread| G 1 1/4
e03| Heating flow optional| Male thread| G 1 1/4
e04| Heating return optional| Male thread| G 1 1/4
d46| Ventilation| mm|
d47| Drain| Female thread| G 1/2
h02| Sensor heat pump return| Diameter| 14
Optional connections
12.2 Details on energy consumption
| SBP 100 classic
---|---
| 235200
Manufacturer| STIEBEL ELTRON
Model-identification of the supplier| SBP 100 classic
Energy efficiency class| C
standing loss S………………w| 50
storage volume V| 99
12.3 Data table
Energy data Energy efficiency class Standby energy consumption/24 h at 65 °C Hydraulic data Rated capacity Application limits, Max. permissible pressure Test pressure Max. permissible temperature Dimensions Height Width Depth Weights Weight (wet) Weight (dry)
| | SBP 100 classic
---|---|---
| KWH| 235200
Energy data| C
Energy efficiency class| 1,2
Standby energy consumption/24 h at 65 °C| 1| 100
Hydraulic data| kWh| 0,3
Rated capacity| l| 0,45
Application limits| MPa| 95
Max. permissible pressure| MPa| 877
Test pressure| °C| 510
Max. permissible temperature| mm| 510
Dimensions| mm| 120
Height| mm| 21
Width| kg| 510
Depth| kg| 510
Weights| kg|
Weight (wet)…………………………………………kg| 120
Weight (dry)kg,……………………………………………… kg| 21
Guarantee
The guarantee conditions of our German companies do not apply to appliances
acquired outside of Germany. In countries where our subsidiaries sell our
products, a guarantee can only be issued by those subsidiaries. Such a
guarantee is only granted if the subsidiary has issued its own terms of the
guarantee. No other guarantee will be granted.
We shall not provide any guarantee for appliances acquired in countries where
we have no subsidiary to sell our products. This will not affect warranties
issued by any importers.
Environment and recycling
We would ask you to help protect the environment. After use, dispose of the
various materials in accordance with national regulations.
www.stiebel-eltron.com
Deutschland
STIEBEL ELTRON GmbH & Co. KG
Dr.-Stiebel-Straße 33 | 37603 Holzminden
Tel. 05531 702-0 | Fax 05531 702-480
info@stiebel-eltron.de
www.stiebel-eltron.de
United Kingdom and Ireland
STIEBEL ELTRON UK Ltd.
Unit 12 Stadiu
m Court
Stadium Road | CH62 3RP Bromborough
Tel. 0151 346-2300 | Fax 0151 334-2913
info@stiebel-eltron.co.uk
www.stiebel-eltron.co.uk
United States of America
STIEBEL ELTRON, Inc.
17 West Street | 01088 West Hatfield MA
Tel. 0413 247-3380 | Fax 0413 247-3369
info@stiebel-eltron-usa.com
www.stiebel-Eltron-usa.com ****
Subject to errors and technical changes!
Stand 9646
Documents / Resources
|
STIEBEL ELTRON SBP 100 Classic Heating Buffer
Cylinder
[pdf] Instruction Manual
SBP 100, Classic Heating Buffer Cylinder
---|---
References
- Home - domain expired
- Home - domain expired
- Sachverständigenbüro ELTRON - Startseite
- STIEBEL ELTRON International
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>