schweigen isodrive 1600 Motor Instruction Manual

June 5, 2024
schweigen

schweigen isodrive 1600 Motor Instruction Manual

Under our policy of continuous product development, product specifications may change without notice.
Please refer to the online version of the manual for the latest updates and specifications.

Welcome

Thank you for purchasing your new Schweigen Isodrive system.

To get the maximum output from this unit, please read through this guide before use and installation.

This guide contains important information on the correct use and maintenance of the unit, as well as important safety notes. This will ensure your personal safety and the lasting value of your Isodrive system.

Please always retain your proof of purchase to aid in any warranty queries.

This appliance and its packaging are produced by processes that minimise waste and respect the environment.

Please help us to continue this effort to protect the environment by using the appliance efficiently and dispose of the packaging in a responsible manner.

Your Safety

RECEIVING YOUR RANGEHOOD

Please read this section thoroughly before attempting to operate the appliance. Inspect your product upon receipt. Any damage or defects MUST be reported within 48 hours, or no claim will be recognised.

DO NOT INSTALL THIS APPLIANCE IF YOU FIND IT DAMAGED.

If this product is installed damaged, the supplier, nor the retailer, will be responsible for the costs associated with the repair, replacement, removal or re-installation of the appliances.

This appliance is not intended for use by person/s (including children) with reduced physical, sensory or mental capabilities, or lack of experience and/or knowledge. Unless the person has been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance, it is not a toy

Do not install Isodrive motor to a non-Schweigen and/or non-silent rangehood. If you fail to do so, your warranty will be voided.

The manufacturer declines all responsibility in case of failure to adopt proper safety measures.

Ensure that the location in which this appliance is installed, has good and permanent ventilation.

Please consult local laws and regulations and install in accordance.

Use an electrical connector with earth that is correct for your location.

Check that the voltage in your area corresponds to the appliance as indicated on the rating label.

Before Installation

We recommend this appliance to be installed or repaired by an experienced Home Appliances technician.

Please see our website www.schweigen.com.au for experienced installers.

It is dangerous to modify any part of this appliance. Modification of any kind, will immediately void the warranty.

Electrical Cord

Ensure the supply cord is not exposed to heat, chemicals or sharp objects. If the supply cord is damaged, it must be replaced by the manufacturer, service agent or a similarly qualified person in order to avoid a hazard. The power supply cord connection MUST BE installed in such a way that access is easy in case of  emergency.

This guide is for the installation of the Isodrive motor system after the rangehood has been mounted on the wall or roof. (Refer to rangehood installation manual on how to install the rangehood).

NOTE: All PVC pipe and SteelFlex™ ducting measurements are referring to inside measurements, unless otherwise mentioned.

Motor Features

  • Roof and wall mounting with IPX4 degree of weather protection.
  • Super quiet, long vane, backward curved centrifugal fan.
  • Airflow is dependant on installation and the ducting used. Using single 200mm SteelFlex™ duct, you should attain up to 1600m3/hr. The use of a smaller than 200mm ducting would result in a loss of airflow.
  • Simple installation: The motor mounts onto a 150mm PVC pipe for ultimate strength and allows for easy Dektite roof sealing.
  • Industrial quality motor and fan made in Germany and rated at 40,000 hours.
  • Motor is a high efficiency PSC type and rated at 155W costing around the same as two 70W light globes to run.
  • WARRANTY 10 YEARS return to manufacturer. Covers faulty manufacturing or components. It does not cover normal wear and tear, chemical or storm damage, etc. (see warranty card for more information).

General Notes on Installation and Use

This fan unit is designed to be installed using 150mm (ISD) PVC pipe as the initial connection duct to the fan module, and is supplied with a 150mm (ISD) PVC pipe to 200mm (ISD) SteelFlex™ duct bell-mouth adaptor.

This fan is suitable for connection to ducting runs with a minimum inlet area of 22,000mm2 and length up to 10 metres maximum (check with supplier if longer duct length required). Where possible SteelFlex™ ducting mustbe extended sufficiently to  present a smooth air passage with bends of at least the radius of twice the diameter of the duct. Excessive bends in the ducting will compromised extraction.

WARNING: The rangehood must not be ducted into a wall cavity or a ceiling space, where a build up of grease can occur and become a potential fire risk. This will void your warranty.

NOTE: Fan module and Steelflex™ duct are acoustically matched. Use of semi-rigid or rigid ducting will result in increased noise and may void warranty. See installation instruction notes ‘Why Schweigen SteelFlex™ Safety Duct’.

Recommended Installation Distance

Isodrive 1600 motor, recommended 5 to 6 metres of SteelFlex™ ducting and with at least two bends.

NOTE: Installations less than 5 to 6 metres will increase extraction power this will result in higher noise level.
Maximum duct length is 10 metres. Check with supplier if longer duct length is required. Do not reduce the duct size at any time and avoid sharp bends.

Minimum Mounting Height

This fan unit is intended for mounting at a minimum height of 2.1 metres (measured to the lower part of the fan impeller) above a floor or the ground.

Avoidance of Back Flow

Care should be taken to avoid the back flow of gases into the room from the open flue of gas or other open fire appliances.

Safety of Children
This fan is not intended for use by young children or infirm persons without supervision.

Replacement of Supply Cord
If the supply cord is damaged, it must be replaced by a service agent or suitably qualified person in order to avoid a hazard.

Why Schweigen SteelFlex™ Safety Duct

Schweigen SteelFlex™ is an ultra-strong and flexible high-performance safety ducting made of Shirikon Firemesh® – a tri-layer tear-resistant UV-treated sleeve. Both are developed by Schweigen – the Silent Rangehood specialists, for quiet and efficient high-volume transfers of temperature-sensitive air. Engineered to enhance the health and safety of your home, Schweigen SteelFlex™ is antimicrobial treated, thermally insulated and acoustically dampened.
It is fireproof, pest and crush proof with a treated surface that prevents the build-up of grease and bacteria.

Schweigen’s unique Isodrive system works in the opposite way to conventional rangehoods, pulling air through the hood and acoustically matched ducting, producing almost silent high volume flow. The use of a complete rigid or semi- rigid ducting system will allow an organ piping effect to occur; like a didgeridoo where a noise is produced at one end of a hollow rigid pipe and the noise is amplified out the other

The Isodrive system places the noise outside the house.

WARNING: Installation without the use of at least the minimum recommended length of acoustically matched SteelFlex™ in the system will void performance expectations. Any installation problem must be reported to Schweigen. Call outs relating to incorrect installation will result in a service fee direct to the customer. Schweigen takes no responsibility for problems caused by faulty installation, this may void warranty. An experienced installer list can be obtained from Schweigen website www.schweigen.com.au or by calling 1300 881 693.

Description

NOTE
For more SteelFlex™ ducting instructions,

Isodrive Motor

Included in the box:

  1. Isodrive 1600 motor (405W x 220H mm approx.) Approx. 3 metre, 10amp cable and standard plug
  2. Fire resistant 150mm (160mm outside dimension) PVC riser pipe
  3. SteelFlex™ safety ducting. Approx. 6 metres, 200mm (210mm outside dimension) diameter
  4. Bell-mouth adapter ring 200mm duct to 150mm riser
  5. Weather Shield Should be installed to prevent rain/water entering the unit
  6. Backdraft Shutter
  7. 2 x Steel ring clamps for attaching ducting to rangehood and motor
  8. 6 x 20mm self-drilling button head screws
  9. 3 x 20mm self-driling screws (for weather shield)

Not included in the box:

  • Roof seal kit / Dektite
  • Support straps for poly pipe which connects to the roof truss
  • Aluminium foil tape
  • Hanging bracket required for wall mount Part number P1107
  • Wall Cover Plate (wall mount only)Part number P1108
  • Mounting Flange (wall mount only) Part number P40113MF

Installation

Roof Installation

Recommended duct length: 1600 motor — 5 to 6 metres.

Mount 150mm (ISD) rigid PVC pipe securely to beams, trusses or other appropriate structures: refer figure 1.
The pipe should be mounted vertically with the roof penetration being sealed using a Dektite or other appropriate sealing membrane or device.

Ensure that the PVC pipe protrudes at least 50mm past the top of the Dektite, checking that the fan assembly clears the roof cladding at upper edge, refer figure 1 – Roof Mount Option.

Pass power cord and plug through mounting flange and pipe, then out the slotted PVC pipe for connection to the socket coming from the canopy/rangehood. Refer to figure 4.

Do not insert plug into socket outlet or switch on until installation has been completed. Fit fan module to pipe and fix in position using side locking screw.

Certain external installation configurations may cause audible levels of noise to be heard due to the air being expelled from the motor. To minimize external noise disturbance you can use between 6 to 10 metres of SteelFlex™ duct to place the Isodrive motor in an appropriate position.

Please be aware that the 1600 motor is capable of expelling air at 1600m3/hr

For more information on environmental noise limit and conditions please contact your local Council. We have a list of experienced installers available on the Schweigen website.

Do not install the SteelFlex™ in a straight line and minimum of two gentle bends in the ducts is required.

Roof mount option
Figure 1: Roof mount option

Flat Roof Installation

Flat roof mounting using optional mounting flange*.

Flat Roof Installation
Figure 2: Flat roof installation

IMPORTANT

It is a requirement to use the hanging bracket for all wall mount installations.
Please refer to the illustrations for mounting.

Wall Installation

This type of installation is similar to roof mounting, ensuring that the pipe extends at least 50mm past the wall surface refer figure 3. If the pipe length is shortened, reproduce the power cord exit slot on the inside of the wall.

IMPORTANT FOR 1600 MOTOR: Weather shield must be fitted to the top cover of the side flange using the 3 screws provided. Also, it is required to use the hanging bracket for wall mount installation.

NOTE: By decreasing the length of the SteelFlex™ duct from which specified (refer to installation instructions) there will be an increase in airflow and noise levels as a result. This increase in airflow can cause movement of air to be heard through the system and inhibit the system to run silently

Wall Installation
Figure 3: Wall installation

Wall mount option
Figure 4: Wall mount option

Through Wall Installation with Backdraft Shutter

Due to the weight and to create stability for the Isodrive 1600 motor, it is require to use a hanging bracket. Warranty will be void if a hanging bracket is not used.

Figure 5: Backdraft shutter wall mount

Fan Unit Shutter Assembly for Isodrive 1600
  1. Assemble by fitting shutter assembly into fan inlet shroud moulding, ensuring that attaching screws align with holes. Alignment can be checked visually by folding in shutter flaps.
  2. Fully tighten both screws and re-check fitment into holes.
  3. Fit assembly to duct pipe as per installation instructions supplied.
    Shutter assembly
    Figure 6: Shutter assembly

Twin Motor Installation (suitable for rangehoods with two 200mm outlets)

Where two motors are to be used, follow the method below. Each motor should have a separate flue pipe. Refer figure 7. The two motors can be wired by an electrician.

Roof mount option
Figure 7: Roof mount option

Twin Motor Installation (suitable for rangehoods with one 200mm outlet)

Where two motors are to be used and there is only one 200mm outlet, follow the below methods for each motor then join into the “Y” piece prior to joining ducting to the canopy / rangehood. Refer figure 8.

The two motors can be wired by one of the following methods:

  • Wired into one plug by an electrician
  • A double adaptor plugged into the lead from the canopy / rangehood
  • A double GPO powered from the canopy
    Roof mount option
    Figure 8: Roof mount option
Single Motor Installation Twin 200mm Outlet

(suitable for rangehoods with two 200mm outlets and one 1600 Isodrive motor)

This is for use where one motor is to be used and there are two 200mm outlets, refer figure 9.

Single Motor Installation

Measurements

Measurements for Isodrive 1600 (Not to Scale)

Figure 10: Measurements for Isodrive 1600

SteelFlex™ Safety Duct

SteelFlex™ Safety Ducting

SteelFlex™ safety ducting must be fully extended and cut to the required length upon installation. Maximum fan performance will not be achieved unless the ducting is fully extended. Failure to fully extend ducting results in a smaller air passage and lower airflows. Incorrect installation may reduce airflow or increase noise levels. Call outs relating to incorrect installation will result in a service fee directed to  customer. Schweigen will take no responsibility for problems caused by faulty installation. A list of experienced installers can be obtained from the Schweigen website www.schweigen.com.au.

SteelFlex™ Safety Ducting
Figure 11: SteelFlex™ Safety Ducting

Assembling SteelFlex™ Safety Duct

SteelFlex™ safety duct must be secured to either the bell-mouth adapter ring or a 200mm mounting pipe.

Parts required:

  1. SteelFlex™ safety ducting
  2. Steel ring clamp
  3. Bell-mouth adapter ring 200mm duct to 150mm riser
  4. 150mm PVC riser pipe
  5. 20mm self-drilling button head screws

Parts required

  1. Slide the steel ring clamp over the end of the duct then insert the bell-mouth adapter ring into the duct end
    Assembling SteelFlex™ Safety Duct

  2. Secure duct to the bell-mouth adapter at regular intervals with 4 x 20mm button
    head screws
    Assembling SteelFlex™ Safety Duct

  3. Slide the steel ring clamp back up and tighten to secure the bell-mouth adapter
    and the duct
    Assembling SteelFlex™ Safety Duct

  4. Attach the mounting pipe to the bell-mouth adapter and secure with 1 x 20mm button head screw
    Assembling SteelFlex™ Safety Duct

Figure 12: Duct assembling

NOTE: Do not use duct tape to fasten the duct – the screws and hose clamp are adequate to secure the duct to the bell-mouth adapter ring.

Shallow Roof Space

In shallow roof spaces, do not crush or kink SteelFlex™ ducting, as it will reduce air flow severely. 90 degree curve made of PVC or galvanise can be used as a substitute for the bend.

Shallow roof space
Figure 13: Shallow roof space

Important Note

Please do not crush or kink SteelFlex™ ducting, as it will reduce air flow and may cause noise to occur through the system. Ducting needs to be kept taut at all times.

SteelFlex™ duct recommended installation Figure 14: SteelFlex™ duct recommended installation

Securing SteelFlex™ Safety Duct

SteelFlex™ safety duct must be installed with supports at maximum intervals of 1.5 metres. SteelFlex™ safety ductwork can be supported by using good quality gaffer or aluminium foil tape. Provided that it does not restrict the internal diameter of the ducting. Ducting installed looped over hanging beams should be installed in such a manner as to ensure the changes of direction are gradual. Support of the ducting with the use of hangers may be required, see option 2.
NOTE: Ducting should be kept taut at all times

  • Option 1 Secure the SteelFlex™ duct to the beam
    Securing SteelFlex™ Safety DuctSecuring SteelFlex™ Safety
Duct

  • Option 2 Support SteelFlex™ duct by using hangers.
    Securing SteelFlex™ Safety Duct
    NOTE: Care shall be taken to minimize sagging or snaking of the duct between  supports.

Parts List

Parts List for Isodrive 1600

Number Part Number Description Quantity
1 P1120 M4X160mm Pan Head Screw 4
P1120N M4 KEPS Nut (not shown in figure) 4
5 P1114 Capacitor 3.5μF 1
9 P1100 Fan Motor Mounting Bracket 1
10 P1102 Fan Base Spinning 1
11 P1113 Heyco Snap Bushing 1
12 P40113 Base Moulding 1
13 P1124 M4X12mm Hex Washer S/T Screw 11
14 200MM BDSS BUILD ASS Shutter Assembly ****

1

15| P1111| Power Cable 3 Core| 1
16| P1101| Fan Top Spinning| 1
17| P1104| Side Mount Cover Weather Shield| 1
18| P1105| Fan Guard| 1
19| P1126| M4X8mm Machine Screw with Spring Washer| 4
20| P1110R| Centrifugal Fan/Motor Unit| 1
21| P1106| Hanging Plate| 1
22| P1107| Hanging bracket (Optional)| 1
23| P1108| Wall Cover Plate (Optional)| 1
23a| P40113MF| Mounting Flange (Optional)| 1
24| P1069| Slotted Pipe (150mmX455mm)| 1
25| P40114| Bell Mouth Adaptor| 1

Maintenance

Roof Restoration or Cleaning

Before doing your roof restoration or cleaning, please completely cover the outside motor system and avoid all chemical contact.

Figure 16: Avoid chemical contact to motor system

IMPORTANT

Any damages caused by the use of chemical products are not covered by warranty

Warranty / Disclaimer

Warranty (See warranty for more information)
Isodrive motor has a 10-Year replacement product warranty. The consumer is responsible for any charges associated with removal of the faulty unit and installation of the new unit. The customer is also responsible for any freight charges incurred in this change over process. Schweigen SteelFlex™ comes with a Lifetime Warranty.

Disclaimer

Under our policy of continuous product development, product specifications may change without notice.
Prospective purchasers should therefore check with the retailer to ensure this publication correctly describes the products being offered for sale. All information supplied is to be used for general reference purposes only and is on the understanding that Schweigen Home Appliances will not be liable for any loss, liability or damage of whatever kind arising as a result of any reliance upon such information. All pictures used in the guide are for illustrative purposes only.

Support

Australia Unit 4/1-5 Lake Drive, Dingley Village, Victoria 3172. Phone 1300 881 693
Email sales@schweigen.com.au Web www.schweigen.com.au
New Zealand 5 Tolich Place, Henderson, Auckland 0610. Phone 0800 200 510
Email info.parex@emerson.com Web www.parex.co.nz

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

schweigen User Manuals

Related Manuals