HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer User Guide

June 5, 2024
Holman

QuikDial™ 4x Outlet Digital Tap TimerHOLMAN CO6004 QuikDial 4x Outlet
Digital Tap Timer

User Guide
www.holmanindustries.com.au

PRODUCT CODE: CO6004

HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
QR

Overview

Main Components

  1.  ZONE 1 outlet
  2. ZONE 2 outlet
  3. ZONE 3 outlet
  4. ZONE 4 outlet Each outlet is 20mm BSP with 12mm snap‑on connection included
  5. 20mm BSP tap nut inlet
  6. Tap connection locking nut
  7. Display
  8. ON/OFF
  9. Main dial
  10.  Battery compartment: Requires 2× AA alkaline batteries only (not included)

Overview (continued)
Additional Functions

 Inactivity on your QuikDial Tap Timer controls for 6 seconds will return to the default system mode displaying the current time
 Removing the AA batteries will reset all clock and schedule settings
To reset your QuikDial Tap Timer, remove the batteries and twist the main dial until the display is completely blank
 For use with cold water only

Specifications

Interval scheduling 1, 2, 3, 6 or 12 hours, or 1‑7 days
Watering duration 1‑30 minutes
Working pressure 30‑1200 kPa
Maximum flow rate 25 L/min
Connections 20mm BSP inlet / 20mm BSP outlet
Working temperature 3°C to 50°C
Batteries 2× AA alkaline (not included)

Setup

Battery Installation

  1.  Install 2× 1.5v AA alkaline batteries into your QuikDial Tap Timer, as indicated in the battery compartment [a]

HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer - alkaline
batteri

After installing the batteries, the display will flash and your QuikDial will make clicking noises as part of the start‑up phase
Once the start‑up process is complete, the clock will display as follows, with the time separator flashing [b] and the battery indicated as full [c]HOLMAN
CO6004 QuikDial 4x Outlet Digital Tap Timer - separator

Setup Process
Your QuickDial features a quick setup process across 5 key steps.
Use the main dial to scroll through the main menu for each stepHOLMAN CO6004
QuikDial 4x Outlet Digital Tap Timer - scroll

Setup (continued)
Zone

This process is to select which zones will be watered as part of your schedule

  1. Turn the main dial to select ZONE [a] in the main menu
    HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
ZONE

  2. Press the main dial to edit zones
      The zone selector [b] will flash around ZONE 1 and indicate as ON [c] HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer - flash
around

  3. Press the main dial to toggle ZONE 1 ON or OFF as desired
    When a zone is turned OFF, the zone number [d] will disappear and the OFF indicator [e] will be displayed
    The zone selector [f] will remain flashing
    HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
selector

  4. Turn the main dial to the next zone
    The zone selector [g] will flash around the next zone and indicate as OFF [h] HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer - flash
garound

  5.  Press the main dial to toggle the zone ON or OFF as desired

  6. Repeat steps 4-5 for the remaining zones

  7. After ZONE 4 has been set to ON or OFF, turn the main dial one more step
    The zone selectors will flash around all zones [i], and the status of each zone will be indicated by their respective numbers being present (ON) [j] or missing (OFF) [k] HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
confirm your zone

  8. To confirm your zone settings, press the main dial
      Alternatively, to go back and change your zone settings, turn the dial another step and repeat steps 3-7
    Once your zones are confirmed, ZONE will flash in the main menu [l] and the active zones will be shown [m]

HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer - active
zones Setup (continued)
Set Clock

This process is to set the system clock for your QuikDial
Your QuikDial system time is always in 24‑hour format (military time)

  1. Turn the main dial to select SET CLOCK [a] in the main menu

  2.  Press the main dial. The current hour [b] will begin flashing
    HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
current

  3.  Turn the main dial to adjust the hour to the current time

  4.  Press the main dial to confirm the current hour. The current minute will begin flashing [c] HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer - adjust the minute t

  5. Turn the main dial to adjust the minute to the current time

  6. Press the main dial to confirm the current minute
      SET CLOCK will flash again in the main menu [d], to indicate the system time [e] has been set

Setup (continued)
Start Time

  This process is to set the START TIME for watering of your active zones
This START TIME is applied to all zones, but is only active on the zones that have been toggled ON in the previous instructions
Refer back to Zone for more information on enabling or disabling zones

  1. Turn the main dial to  select START TIME [a]in the main menu
    HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer - Sselect START
TIME
     This will display the current START TIME [b]. By default, this is set to 08:00 (8:00 am)

  2.  Press the main dial. The START TIME hour [c] will begin flashing
    HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer - START
TIME

  3.  Turn the main dial to adjust the hour to the desired START TIME

  4. Press the main dial to confirm the hour. The START TIME minute will begin flashing [c] HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer - START TIME minute

  5.  Turn the main dial to adjust the minute to the desired START TIME
    Setup (continued)
    Start Time (continued)

  6. Press the main dial to confirm the minute

START TIM E in the main menu [d] will flash again, to indicate it has been set [e]

HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
findicate

How Long (Watering Duration)

This process is to set the watering duration of your active zones
  This duration is applied to all zones, but is only active on the zones that have been toggled ON in the previous instructions
Refer back to Zone for more information on enabling or disabling zones

  1. Turn the main dial to select HOW LONG [a] in the main menu

This will display the current watering duration [b]. By default, this is set to 5 minutes

  1. Press the main dial. The duration in minutes [c] will begin flashing

HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
duration

Setup (continued)
How Long (continued)

3. Turn the main dial to adjust duration as desired
4. Press the main dial to confirm the duration

HOW LONG in the main menu [d] will flash again, to indicate the duration has been set [e]

How Often (Watering Interval)

  This process is to set the interval time between watering sessions of your active zones
This interval is applied to all zones, but is only active on the zones that have been toggled ON in the previous instructions
  Refer back to Zone for more information on enabling or disabling zones

  1. Turn the main dial to select HOW OFTEN [a] in the main menu

  This will display the current watering interval [b]. By default, this is set to 1 day

Setup (continued)
How Long (continued)
2. Press the main dial. The interval [c] will begin flashingHOLMAN
CO6004 QuikDial 4x Outlet Digital Tap Timer - interval

3. Turn the main dial to adjust the interval length in DAYS from 1 to 7
For shorter watering intervals in HOURS [d], turn the main dial beyond 7 days. The interval will now show as 1 hour HOLMAN CO6004 QuikDial 4x Outlet
Digital Tap Timer - beyond

  Keep turning the main dial to adjust the watering interval in HOURS
  Hourly watering intervals are available in 1, 2, 3, 6 or 12 hours
To go back to setting the interval in DAYS [e], keep turning the dial beyond 2 hours. The intervalwill return to 1 dayHOLMAN CO6004 QuikDial 4x Outlet
Digital Tap Timer - DAYS

4. With the desired interval time showing, press the main dial to confirmHOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
OFTEN

  HOW OFTEN in the main menu [f] will flash again, to indicate the interval has been set [g]

Operation

Automatic Watering

  1. For automatic watering, ensure ZONE, SET CLOCK, START TIME, HOW LONG and HOW OFTEN have all been set correctly as per the previous instructions

  2. After a period of inactivity on your QuikDial controls, the  set watering schedule will beactive in the background as per your confirmed settings
      In this state, your QuikDial display will cycle between the current time [a] and the amount of time left before your NEXT watering session [b] HOLMAN
CO6004 QuikDial 4x Outlet Digital Tap Timer - current
time

  3. When the current interval time [b] lapses, the zones will start watering in sequential order
      During watering, the sprinkler animation [c] will be active, the current zone [d] will flash, and the remaining watering time [e] will also flash as it counts down
      Additional zones scheduled for watering will also show [f]

HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
sprinkler

Operation (continued)
Manual Watering

  1. For manual (instant) watering, press ON/OFF

  2. The zone selector [a] will flash. Twist the main dial to select a zone
    HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
selectdor

  3. Press the main dial to water immediately for the pre‑set duration [b]. By default, this is 10 minutes
      During watering, the sprinkler animation [c] will be active, and the current zone [d] will flashHOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer -
scheduled

  4. Once watering, the remainingtime [e] will also flash to indicate it is adjustable

  5. Turn the main dial to adjust the watering time as desired
    The minimum watering time is 1 minute
    The maximum watering time is 31 minutes

  6. After a short period of time, the remaining watering time will stop flashing to indicate it has been set
      To stop watering before the remaining time has lapsed, press ON/OFF and your QuikDial will return to the default display
      If the remaining time stops flashing before  you were able to adjust it, press ON/OFF to stop watering, and restartthe manual watering process from Step 1

Maintenance

Cold Weather
Your QuikDial should be removed from the tap and stored away during winter
Keep your tap timer out of freezing conditions as this can damage internal components Batteries
  Remove batteries from your QuikDial during periods of non‑use–this will erase all settings
Battery leakage can cause corrosion and damage to your QuikDial
Do not mix old and new batteries
Do not use rechargeable batteries

Neet halp? Just ask!

The Holman website has a host of additional information on features. Head to support.holmanindustries.com.au for more tips, tricks and support content.
If you still need help, feel free to email our friendly Customer Service team at support@holmanindustries.com.au or call at 08 9416 9999.

https://support.holmanindustries.com.au/?=qrHOLMAN CO6004 QuikDial 4x
Outlet Digital Tap Timer - fig

We really appreciate having you as a customer, and
would like to say thank you for choosing us.
We recommend registering your new product on our website. This will ensure we have
a copy of your purchase and activate an extended warranty. Keep up to date to with
relevant product information and special offers available through our newsletter.
www.holmanindustries.com.au/product- registration/

For the #SMARYGARDENER


Copyright © 2021 Holman Industries

Documents / Resources

| HOLMAN CO6004 QuikDial 4x Outlet Digital Tap Timer [pdf] User Guide
CO6004, QuikDial 4x Outlet Digital Tap Timer, CO6004 QuikDial 4x Outlet Digital Tap Timer
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals