- Product Name: Frick Quantum HD Unity
- Model Number: GPS0053-CE-EN
- Version: 1.0 Rev A
- Release Date: 2024-07-26
Product Usage Instructions
Planning
This section is designed to harden your attack surface before the new or
upgraded system is turned over to runtime operations. Security hardening
begins with careful planning prior to deployment.
Deployment
When deploying the Frick Quantum HD Unity, follow these steps:
Hardening
While many products include secure-by-default safeguards, additional
hardening is usually required to meet the security requirements of the target
environment. Apply the correct level of protection based on customer policies
and regulations.
Hardening Checklist
Complete the following tasks to harden the product:
- Hardening Step 1: Disable unused network ports
- Hardening Step 2: Equipment network isolation
- Hardening Step 3: Software upgrades
- Hardening Step 4: Manage pin numbers
Configure Network Ports
To limit network traffic, disable unused network ports based on the
required services. Consult the table below for reference.
Isolated Internet
Avoid connecting the Quantum HD Unity panel directly to the internet. Use a
VPN or secure remote connection for features like email or remote monitoring.
FAQ
-
Q: Why is it important to disable unused network ports?
A: Disabling unused network ports helps prevent unauthorized access and reduces the attack surface of the system. -
Q: Can the Quantum HD Unity panel be connected directly to the internet?
A: It is recommended not to connect the panel directly to the internet to minimize cybersecurity risks. Use secure connections like VPN for remote monitoring.
Frick Quantum HD Unity Hardening Requirements
Introduction
Our practices provide peace of mind to our customers with a holistic cyber mind set beginning at initial project design concept, and is supported through deployment, including a rapid incident response to meet comprehensive and evolving cybersecurity environments.
This hardening document intends to provide cybersecurity requirements for the
Frick Quantum HD Unity Control Panel for configuration and upgrade management.
As cybersecurity threats affect all connected devices, it is important to
ensure that cybersecurity is considered throughout the planning, deployment
and maintenance phases associated with a solution’s functional operation.
Legal disclaimer
The cybersecurity practices described in this guide are recommended practices to facilitate the secure installation and configuration of the products described herein. However, Johnson Controls cannot guarantee that the implementation of the cybersecurity practices or recommendations described in this guide will ensure the security of the relevant product or system, or prevent, or alter the potential impact of, any unauthorized access or damage caused by a cybersecurity incident.
This guide is provided “as is”, and Johnson Controls makes no representation or warranty, expressed or implied, as to the efficacy of the cybersecurity practices or recommendations described within. Johnson Controls disclaims all liability for any damages that may occur because of, or despite, reliance on this guide or compliance with any cybersecurity practices or recommendations set forth herein.
Planning
This section helps plan for the implementation of security requirements for
Frick Quantum HD Unity control panels.
Internet connectivity
Internet access increases your cybersecurity footprint and attack area which
requires additional hardening steps. The hardening steps in section 2 must be
taken to limit external access.
Hardening methodology
While most products provide onboard security safeguards, including secure-by-
default settings, we recommend that the device is hardened according to the
guidance outlined in section 2.
Generally, you should aim for a defense-in-depth strategy employing standard
IT hardening methods and compensating controls as needed to be compliment with
the base security features of each product.
Deployment
This section is designed to harden your attack surface before the new or upgraded system is turned over to runtime operations. Security hardening begins with careful planning prior to deployment.
Hardening
While many products include secure-by-default safeguards, additional hardening
is usually required to meet the security requirements of the target
environment. It is important to apply the correct level of protection as
warranted by customer policies and other applicable regulations that may
govern the application security settings for this deployment.
Hardening checklist
This checklist provides a list of hardening steps you may choose to go
through. The actual steps you will take are based on the features required for
your specific products and application environment.
To harden this product, complete the following tasks:
Hardening
- Step 1: Disable unused network ports Hardening
- Step 2: Equipment network isolation Hardening Step
- 3: Software upgrades Hardening Step
- 4: Manage pin numbers
Configure network ports
Quantum HD Unity panels often communicate over Ethernet networks, but the type
of communication will depend on the software features that are used. Use a
network firewall to allow only approved communication. Below are steps to
limit network traffic to just the services that are needed.
Hardening Step 1: Disable unused network ports
To decide what ports to open refer to the table below. Block all unused ports.
For example, if you no longer need to use Modbus TCP and are not using port
502 for any other use, block port 502. NOTE: Before blocking ports, consult
your Frick Factor and IT department.
Table 2.3.1
Network Port| Protocol| Int / Ext| Feature|
Description
---|---|---|---|---
80| TCP| Internal| HTTP| Web browser HMI WebSockets
465, 587, or user configurable| TCP| External| Email| Email notification
502| TCP| Internal| Modbus| Used for Modbus messaging
44818| TCP| Internal| Allen-Bradley EtherNet/IP| Used for Rockwell Allen-
Bradley messaging
Isolated internet
Connecting any system to the internet always increases cybersecurity risk. To
harden your system, it is recommended that you do not connect the Quantum HD
Unity panel directly to the internet.
However, features such as email or remote monitoring will require an internet
connection. If remote monitoring connections are used outside the local
network, they should be through a VPN or other secure remote connection.
Hardening Step 2: Equipment network isolation
Quantum HD Unity panels should communicate on a dedicated internal Ethernet
equipment network that is isolated from other Ethernet networks and Internet
connections. If connections to external networks are required, use a network
firewall to only allow communication for specific services.
Apply upgrades
It is best practice to apply the most current software upgrades. These
upgrades can include cybersecurity improvements as well as feature additions
and other software improvements. Review the release notes and prioritize the
benefits of the update. The overall benefit should include the improved
protection that will lower the cybersecurity risk.
Hardening Step 3: Software upgrades
Review the Quantum HD Unity product page on the
frickcontrols.com website for the latest software
and upgrade procedure at the following link – https://frickcontrols.com
/quantum-hd-unity-q6
Managing pin numbers
Pin numbers are used to control the level of access granted to users of the
control panel. There are three levels of access that may be granted. Always
grant access with the principle of Least Privilege. In general, this means:
- Only the minimum necessary rights should be assigned to a user that requests access
- Access rights should be in effect for the shortest duration necessary
Hardening Step 4: Manage pin numbers
Pin numbers should be reviewed and changed when specific events occur. For
example:
- When new personnel need to access the control panel
- When personnel are no longer employed by the organization
- When personnel have changed roles, and have either increased or decreased responsibilities
During these events, immediately update the pin number. This ensures that people with the appropriate roles can access the panels with the correct privileges.