Liquid Tank

Infusion
Twist the Cap counterclockwise to open the tank. Upon infusion, screw the Cap clockwise till tight.

To protect the parts from chemical splash damage, direct pesticide infusion is NOT allowed when the tank is installed on the UAV.

Tank Removal/Installation
Pick up with force/put down with care to remove/install the Liquid Tank. XAG-3WWDZ-20BH-P40-Agricultural-Drone-fig2

WARNING:
Please DO handle the tank with pesticide inside with care. Emptying liquid tank/granule container beforehand to enhance the efficiency of aerial mapping is recommended. A drone installing RealTerra is unable to spray or spread.

APP Interface Introduction “Field” Tab (Main)

XAG-3WWDZ-20BH-P40-Agricultural-Drone-fig3

  • Device List: Full device list
  • Operator: Operator’s location
  • “Field” Tab: Main field options tab Functions: New fields, New fields group, New HDMap, Import data, Bind devices
  • Map Layers: Select map type Focus on Aircraft: Centre screen on aircraft
  • Focus on Operator: Centre screen on operator
  • Measure: Measure distance
  • Aircraft: Aircraft’s location
  • “Operation” Tab: Main operation options tab
  • “My Account” Tab: Main account options tab

“Operation”Tab

Tap on the “Operation” tab to view the operation options. XAG-3WWDZ-20BH-P40
-Agricultural-Drone-fig4

  • Return: Return to “Field” Tab (Main) Operation Area: Area of selected field Spraying Settings: Spraying settings
  • Start Operation: Start operation
  • Volume Required: Estimated volume required
  • Flights Required: Estimated flights required
  • for current operation FPV: First-person-view camera
  • Flight Settings: Flight settings

Appendix

Wiring Quick GuideXAG-3WWDZ-20BH-P40-Agricultural-Drone-
fig5

The guideline on this page is applicable for all the connections of P40 Agricultural UAV.

Description of Status Indicator

Super X4 Intelligent Control System Indicator Get to know the current status of the drone by checking Super X4 Intelligent Control System Indicator. Details are as follows:

XAG-3WWDZ-20BH-P40-Agricultural-Drone-fig6

Flight Indicator
There are one Flight Indicatoron the side of each motor mount, Details are as follows. XAG-3WWDZ-20BH-P40-Agricultural-Drone-fig7 XAG-3WWDZ-20BH-P40-Agricultural-Drone-fig8

Specifications

P40 Agricultural UAV

XAG-3WWDZ-20BH-P40-Agricultural-Drone-fig9

Flight Parameters

XAG-3WWDZ-20BH-P40-Agricultural-Drone-fig10

RevoSpray System XAG-3WWDZ-20BH-P40-Agricultural-Drone-
fig11

XAG-3WWDZ-20BH-P40-Agricultural-Drone-fig12

Obstacle Sensing & Avoidance System XAG-3WWDZ-20BH-P40-Agricultural-
Drone-fig13 XAG-3WWDZ-20BH-P40-Agricultural-
Drone-fig14

Propulsion System XAG-3WWDZ-20BH-P40-Agricultural-Drone-
fig15

Tilt Servo XAG-3WWDZ-20BH-P40-Agricultural-Drone-
fig16

Communication & Control System XAG-3WWDZ-20BH-P40-Agricultural-Drone-
fig17

NOTE: The effectiveness of the Obstacle Sensing & Avoidance System depends on the obstacle’s material, location, shape, size, etc. Please ensure the drone is always in your sight during operation. Pay close attention to the drone and use the control stick to avoid obstacles when necessary.

FCC/ISEDC Compliance Notice

This device complies with Part 15 of the FCC Rules and ISEDC licence-exempt RSS standard.. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received,including interference that may cause undesired operation.
    Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

RF Exposure Information
Aircraft complies with FCC/ISEDC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possibility of exceeding the FCC/ISEDC radio frequency exposure limits, human proximity to the antenna shall not be less than 20cm during normal operation.
For Remote Controller (model:GL300N),SAR tests are conducted using standard operating positions accepted by the FCC/ISEDC with the device transmitting at its highest certified power level in all tested frequency bands, although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. Before a new model is a available for sale to the public, it must be tested and certified to the FCC/ISEDC that it does not exceed the exposure limit established by the FCC/ISEDC, Tests for each product are performed in positions and locations as required by the FCC/ISEDC. For Handheld operation, this device has been tested and meets the FCC/ISEDC RF exposure guidelines when used with an accessory designated for this product or when used with an acces sory that contains no metal.
For body worn operation, Remote Controller (model:GL300N) has been tested and meets the FCC/ISEDC RF exposure guidelines when used with an accessory designated for this product or when used with an accessory that Contains no metal and that positions the handset a minimum of 0 cm from the body.
Non-compliance with the above restrictions may result in violation of RF exposure guidelines.

FCC Warning statements in User Manual

FCC RF Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.