XAG 3WWDZ-20BH P40 Agricultural Drone Instruction Manual
- June 5, 2024
- XAG
Table of Contents
XAG 3WWDZ-20BH P40 Agricultural Drone
Liquid Tank
Infusion
Twist the Cap counterclockwise to open the tank. Upon infusion, screw the Cap
clockwise till tight.
To protect the parts from chemical splash damage, direct pesticide infusion is NOT allowed when the tank is installed on the UAV.
Tank Removal/Installation
Pick up with force/put down with care to remove/install the Liquid Tank.
WARNING:
Please DO handle the tank with pesticide inside with care. Emptying liquid
tank/granule container beforehand to enhance the efficiency of aerial mapping
is recommended. A drone installing RealTerra is unable to spray or spread.
APP Interface Introduction “Field” Tab (Main)
- Device List: Full device list
- Operator: Operator’s location
- “Field” Tab: Main field options tab Functions: New fields, New fields group, New HDMap, Import data, Bind devices
- Map Layers: Select map type Focus on Aircraft: Centre screen on aircraft
- Focus on Operator: Centre screen on operator
- Measure: Measure distance
- Aircraft: Aircraft’s location
- “Operation” Tab: Main operation options tab
- “My Account” Tab: Main account options tab
“Operation”Tab
Tap on the “Operation” tab to view the operation options.
- Return: Return to “Field” Tab (Main) Operation Area: Area of selected field Spraying Settings: Spraying settings
- Start Operation: Start operation
- Volume Required: Estimated volume required
- Flights Required: Estimated flights required
- for current operation FPV: First-person-view camera
- Flight Settings: Flight settings
Appendix
Wiring Quick Guide
The guideline on this page is applicable for all the connections of P40 Agricultural UAV.
Description of Status Indicator
Super X4 Intelligent Control System Indicator Get to know the current status of the drone by checking Super X4 Intelligent Control System Indicator. Details are as follows:
Flight Indicator
There are one Flight Indicatoron the side of each motor mount, Details are as
follows.
Specifications
P40 Agricultural UAV
Flight Parameters
RevoSpray System
Obstacle Sensing & Avoidance System
Propulsion System
Tilt Servo
Communication & Control System
NOTE: The effectiveness of the Obstacle Sensing & Avoidance System depends on the obstacle’s material, location, shape, size, etc. Please ensure the drone is always in your sight during operation. Pay close attention to the drone and use the control stick to avoid obstacles when necessary.
FCC/ISEDC Compliance Notice
This device complies with Part 15 of the FCC Rules and ISEDC licence-exempt RSS standard.. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received,including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
RF Exposure Information
Aircraft complies with FCC/ISEDC radiation exposure limits set forth for an
uncontrolled environment. In order to avoid the possibility of exceeding the
FCC/ISEDC radio frequency exposure limits, human proximity to the antenna
shall not be less than 20cm during normal operation.
For Remote Controller (model:GL300N),SAR tests are conducted using standard
operating positions accepted by the FCC/ISEDC with the device transmitting at
its highest certified power level in all tested frequency bands, although the
SAR is determined at the highest certified power level, the actual SAR level
of the device while operating can be well below the maximum value. Before a
new model is a available for sale to the public, it must be tested and
certified to the FCC/ISEDC that it does not exceed the exposure limit
established by the FCC/ISEDC, Tests for each product are performed in
positions and locations as required by the FCC/ISEDC. For Handheld operation,
this device has been tested and meets the FCC/ISEDC RF exposure guidelines
when used with an accessory designated for this product or when used with an
acces sory that contains no metal.
For body worn operation, Remote Controller (model:GL300N) has been tested and
meets the FCC/ISEDC RF exposure guidelines when used with an accessory
designated for this product or when used with an accessory that Contains no
metal and that positions the handset a minimum of 0 cm from the body.
Non-compliance with the above restrictions may result in violation of RF
exposure guidelines.
FCC Warning statements in User Manual
FCC RF Radiation Exposure Statement: This equipment complies with FCC
radiation exposure limits set forth for an uncontrolled environment. This
equipment should be installed and operated with a minimum distance of 20cm
between the radiator and any part of your body.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Caution: The user is cautioned that changes or modifications not
expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.