COSTWAY ES10055US 52-Inch Ceiling Fan Lamp User Manual
- June 5, 2024
- COSTWAY
Table of Contents
- Safety Information
- SPECIFICATION
- TOOLS REQUIRED
- PACKAGE CONTENTS
- Installation of the hanging bracket (suspension part)
- Install the hanging part of the ceiling fan
- Assembly – Hanging the Fan
- Assembly – Attaching the Fan Blades
- Assembly – Attaching the Lamp
- Operation
- Care and Cleaning
- Troubleshooting
- Installation tutorial
- Use of remote control
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
USER’S MANUAL
52″ Ceiling Fan Lamp
ES10055US
THIS INSTRUCTION BOOKLET CONTAINS IMPORTANT SAFETY INFORMATION. PLEASE READ
AND KEEP FOR FUTURE REFERENCE.
Please give us a chance to make it right and do better!
Contact our friendly customer service department for help first.
Replacements for missing or damaged parts will be shipped ASAP!
Follow Costway
Contact Us!
Do NOT return this item.
Contact our friendly customer service department for help first.
Before You Start
Please read all instructions carefully.
Retain instructions for future reference.
Separate and count all parts and hardware.
Read through each step carefully and follow the proper order.
We recommend that, where possible, all items are assembled near to the area
in which they will be placed in use, to avoid moving the product unnecessarily
once assembled.
Always place the product on a flat, steady and stable surface.
Keep all small parts and packaging materials for this product away from
babies and children as they potentially pose a serious choking hazard.
Safety Information
-
To reduce the risk of electric shock, the electricity has been turned off at the circuit breaker or fuse box before begin.
-
AI wiring must be in accordance with the National Electrical Code NASI/NFPA 70-1999 and local electrical codes. Electrical installation should be performed by a qualified licensed electriccian.
-
The outlet box and support structure must be securely mounted and capable of reliably supporting 35Ib.(15.9kg).Use only UL listed outlet boxes marked “Acceptable for Fan Support of 35Ibs(15.9kg)or less.”
-
The fan must be mounted with a minimum of 7 ft. (2m) clearance from the trailing edge of the blades to the floor:
-
Do not operate the reversing switch while the fan blades are in motion. You must turn the fan off and stop the blades before you reverse the blade direction.
-
Do not place objects in the path of the blades.
-
To avoid personal injury or damage to the fan and other items, please be careful when working around or cleaning the fan.
-
Electrical diagrams are for reference only. Light kits that are not packed with the fan must be UL-listed and marked suitable for use with the model fan you are installing.
Switches must be UL General Use Switches. Refer to the instructions packaged with the light kits and switches for proper assembly. -
After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box.The wires should be spread apart with the grounded conductor and the equipment-grounding conductor on one side of the outlet box.
-
All setscrews must be checked and retightened where necessary before installation.
WARNING:To reduce the risk of personal injury, do not bend the blade
brackets (also referred to as flanges) during assembly or after
installation.Do not insert objects in the path of the blades.
WARNING: Remove the rubber motor stops on the bottom of the fan before
installing the blades or testing the motor.
WARNING: To reduce the risk or fire or electric shock,do not use this fan with
any solid-state speed control device.
WARNING:To avoid possible electric shock, turn the electricity off at the main
fuse box before wiring. If you feel you do not have enough electrical wiring
knowledge or experience, contact a I licensed electrician.
WARNING: Electrical diagrams are for reference only. Optional use of any
light kit shall be UL-listed and marked suitable for use with this fan.
WARNING: To reduce the risk of fire, electric shock, or personal
injury, mount to outlet box marked’ Acceptable for fan support of 35 lbs.(15.9
kg)or less ‘and use the screws provided with the outlet box.
Pre- Installation
SPECIFICATION
Size| Speed| Volts| Amps| Watts| RPM| CFM| Net| Gross
Weight| Cube
Feet
---|---|---|---|---|---|---|---|---|---
52 in| Low| 120| 0.21| 11| 62| 1909| 19.61b 8.9kg| 10.9kg| 4.44cu.ft
Medium| 0.35| 28| 100| 2982
High| 0.55| 68| 175| 5171
The above data are for reference only, Actually the motor speed of each
ceiling fan is a little different.
Any products, Subject to actual products as standard.
NOTE:These are approximate measures.They do not include the amps and
wattage used by the light kit.
Specifications & measurements shown are subject to± 5% variations.
TOOLS REQUIRED
HARDWARE INCLUDED
components table
PACKAGE CONTENTS
NOTE: Hardware not shown to actual size.
AA | Blade attachment screw and fiber washer | 16 |
---|---|---|
BB | Plastic wire nut (not to scale) | 3 |
CC | Blade arm screw and lock washer | 1 |
EE | Mounting screws | 4 |
FF | Expansion Bolts | 2 |
GG | Balanced parts package | 1 |
Please check whether above accessories are completed or not?Yes,and install.
Installation of the hanging bracket (suspension part)
For wooden ceiling, use wood screw to drill on the wooden beam or the
“junction box” to fix the hanging bracket (selection is made according to
actual requirements of the customers).
STEP 1A-WOODEN CEILING
SWITCH OFF THE ELECTRICAL MAINS AT THE CIRCUIT BREAKER FUSE BOX.
- Use the Mounting Bracket (A) as a guide, mark the spots where the 4 Self Tapping Screws (B) will be drilled.
- Remove the Mounting Bracket (A), drill 4 holes for 3MM diameter, install the mounting bracket onto wooden ceiling with the 4 SelfTapping Screws (B)& Washers (C).
IMPORTANT: SCREWS MUST BE TIGHTENED TILL SNUG
Note: According to the ceiling of different materials, use different screws
to fix the hanging bracket.
Don’t fix the hanging bracket on the wood ceiling less than 12MM to prevent
danger caused by loosening of screws.
After the hanging bracket is completed, ensure that it can withstand the
tension test of more than 150 LBS/ 68KG for safety.
For concrete ceiling, use the percussion bit with diameter 8mm to drill holes
according to the length of expansion screws. Then use the attached expansion
screws to fix the
hanging bracket onto the ceiling (selection is made according to actual
requirements of the customers).
STEP 2A-CONCRETE CEILING
SWITCH OFF THE ELECTRICAL MAINS AT THE CIRCUIT BREAKER FUSE BOX.
1)Use the Mounting Bracket (A) as a guide, mark the spots where the 4
Expansion Bolts (B) will be drilled.
2)Remove the Mounting Bracket (A), drill 4 holes and insert 4 Expansion Bolts
(B) into the concrete
ceiling, install the mounting bracket and secure with Flat Washers (C), Spring
Washers (D) and Nuts (E).
IMPORTANT: SCREWS & NUTS MUST BE TIGHTENED TILL SNUG
Install the hanging part of the ceiling fan
Install downrod assembly
- Thread the suspender through the suspended clock and coupling cover.
- Then insert the tail of the suspender from the lifting head of the motor.
- After the lateral pin is threaded out from the suspended head position, insert R type pin.
- Tighten the lifting head screws.
- Hang the fan of the hanging pipe into the hanger.
Assembly – Hanging the Fan
Making the electrical connections
WARNING: Each wire not supplied with this fan is designed to accept up to
one 12-gauge house wire and two wires from the fan.If you have larger than
12-gauge house wiring or more than one house wire to connect to the fan
wiring,consult an electrician for the proper size wire nuts to use.
**WARNING:** Remove the rubber motor stops on the bottom of fan before
installing the blades or testing the motor.
IMPORTANT: Use the plastic wire connectors(BB) supplied with your fan. Secure the connectors with electrical tape and ensure there are no loose strands or connections.
a.The motor white wire to the white” to motor N” wire from Recevier with a
wire nut.
b.The motor black wire to the black”to motor L” wire from Receiver with a wire
nut.
c.The lamp blue wire to the blue”to Light” wire from Receiver with a wire nut.
d.The white wire from Outlet Box to the red”AC in N” wire from Receiver with a
wire nut.
e.The black wire from Outlet Box to the red”AC in L” wire from the Receiver
with a wire nut.
~connect te supp!y ground wire to green ground wire from the canopy an@ the
green ground wire from the hanger bracket together using a wire nut.
Tuck all wire nuts and wires carefully up into the Outlet Box, EXCEPT
antenna,which should remain outside Outlet Box
Preparing for mounting
Install remote control
- Carefully push the canopy to the bottom of the mounting bracket, make two sliding holes aligned to the two prominent screws on the mounting bracket, and then turn clockwise until tight.
- Push the canopy ring to the bottom of the canopy, slide the inner holes aligned to the two prominent screws on the mounting bracket again, and turn the canopy ring clockwise until tight.
Preparing for mounting
- Remove the mounting bracket from the canopy by loosening the two canopy screws located in the L shaped slots.
- Remove and save the two canopy screws in the round holes. This will enable you to remove the mounting bracket.
Assembly – Attaching the Fan Blades
- Pass the red washer through the screw.
- Tighten the screw through the blade and tighten it on the arms.
- Repeat the above steps to tighten the four sets of blades.
2. Fastening the blade arms to the motor
WARNING. Remove the rubber motor stops on the bottom ill of the fan before
installing the blades or testing the motor.
NOTE: Your fan features revolutionary advancements for quick and easy
blade installation.Including an alignment post and captive blade arm screws.
NOTE: Your fan blades are reversible.Select the blade side finish which
best accentuates your decor.
- Fasten the arm to the fan-motor assembly by inserting the alignment post in the slot on the bottom of the motor and tightening the pre- installed arm screws.
- Repeat this step for the remaining blade assemblies.
Assembly – Attaching the Lamp
3. Connecting lamp wire
CAUTION:To reduce the risk of electric lH shock,disconnect the electrical circuit to the fan before installing the light fixture.
4. Tightening the screw of the box cover.
- Take the wire into the switching box of the motor.
- Align the opening of switching box of the light at switch locking position of the forward and reverse rotation of the motors switching box. Place the cover. Screw in the screw of the switching box.
‘5.Installing the crystal shade & bulb
WARNING: Allow the shatter-resistant bowl to cool completely before
removing.
CAUTION: Make sure the power is off before attaching or removing the
shatter-resistant bowl.
CAUTION: Do not over tighten the hex nut, overtightening the hex nut may
cause the shatter-resistant bowl to break.
Operation
OPERATING YOUR FAN
The appropriate speed settings for warm or cool weather depends on factors
such as the room size, ceiling height, and number of fans.
The slide switch (XX) controls the direction of the blades: forward (switch
down) or reverse (switch up).
NOTE:Wait for the fan to stop before reversing the direction of the blade
rotation
A. Warm weather-(Forward} A downward airflow creates a cooling effect.
This allows you to set your air conditioner on a higher setting without
affecting your comfort.
B. Cool weather-(Reverse) An upward airflow moves warm air off the
ceiling.This allows you to set heating unit on a lower setting without
affecting your comfort.
Care and Cleaning
WARNING:Make sure the power is off before cleaning your fan.
- Because of the fan’s natural movement, some connections may become loose.Check the support connections,brackets,and blade attachments twice a year. Make sure they are secure. It is not necessary to remove the fan from the celling.
- Clean your fan periodically to help maintain its new appearance over the years. Do not use water when cleaning, as this could damage the motor or the wood, or possibly cause an electric shock. Use only a soft brush or lint-free cloth to avoid scratching the finish. The plathing is sealed with a lacquer to minimize discoloration or tarnishing.
- You can apply a light coat of furniture polish to the wood for additional protection and enhanced beauty. Cover small scratches with a light application of shoe polish.
- You do not need to oil your fan. The motor has permanently-lubricated sealed ball bearings.
Troubleshooting
Problem | Solution |
---|---|
The fan will not start. |
I Check the main and branch circuit fuses or breakers.
0 Check the line wire connections to the fan and switch wire connections in
the switch housing.
0 Ensure Al motor housing screws are snug.
0 Ensure the screws that attach the fan blade bracket to the motor hub are
tight.
0 Ensure the wie nut connetions are not ratting against each other or the
interior wall of the switch housing. 0 Allow a 24-hour ‘breaking in” period.
Most noises associated with a new fan disappear cluing this time. 0 If you are
using the Ceiling Fan light kit,ensure the screws securiig the glassware are
tight.
Check that the light bulbs are also secure.
0 Ensure the canopy is a short distance from the ceiling.lt shoild not touch
the ceiling.
0 Ensure your outlet box is secure and rider isolator pads were used between
the mounting plate and outlet box.
The fan wobbles.| 0 Check that all blades and Blade arm screws are secure.
0 Most fan wobble problems are caused when blade levels are unequal.
0 Check this level by selecting a point on the ceiling above the tip of the
blades.
0 Measure from a point on the center of each blade to the point on the
ceiling.Measure this distance. 0 Rotate the fan until the next blade is
positioned for measurement.
0 Repeat for each bled e.An y measurement deviation should be within 118 in.
0 Run the fan for ten minutes.lf the fan continues to wobble please contact
Customer Service.
Installation tutorial
- Twist the bottom fixing trim out
- Remove the parts from the lamp
- Select the appropriate bulb and install it on the lamp holder.
- lnstall the disassembled parts back to the original place
Use of remote control
LIGHT ON/OFF
1H] Auto-off after 1hr
[2H] Auto-off after 2hr
[4H] Auto-off after 4hr
[8H] Auto-off after 8hr
[Low] FanSpeed Low Level
[MED] FanSpeed Middle Level
[Hi] FanSpeed High level
[STOP] FanSTOP
Welcome to visit our website and purchase our quality products!
With your inspiring rating, COSTWAY will be more consistent to offer you
EASY SHOPPING EXPERIENCE, GOOD PRODUCTS and EFFICIENT SERVICE I
US office: Fontana, California
UK office: Ipswich
- Reward Points
- Exclusive Customer Service
- Personalized Recommendations
- Permanent Shopping Cart
- Order History
5 Star Rating
http://www.costway.com/hysalesrule/qr
We would like to extend our heartfelt thanks to all of our customers for taking time to assemble this product and giving us valuable feedbacks.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>