RESTUBE RT-01301-SP Extreme Float Buoyancy Aid Starter Bundle Instruction Manual
- June 5, 2024
- RESTUBE
Table of Contents
- RESTUBE RT-01301-SP Extreme Float Buoyancy Aid Starter Bundle
- OVERVIEW
- Safety notes
- Operation and maintenance
- How do I fasten Restube correctly
- **Harness attachement
- Troubleshooting
- Storage, care, maintenance and disposal of your RESTUBE product
- Disposal
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RESTUBE RT-01301-SP Extreme Float Buoyancy Aid Starter Bundle
OVERVIEW
Safety notes
- Important notice to begin Anyone who wishes to see these instructions on video for more background information about
- RESTUBE and the team may visit the following link: restube.com/extreme
- Read the product information carefully before using the product!
- Observe the notes inside the product and on the waist strap tag!
- Check Restube before each use, see chapter 2.
- Should you detect defects during inspection, please contact the dealer/manufacturer. >>> info@restube.com
- Never attempt to repair Restube by yourself!
- Restube…
- only works as a floating device when it is completely inflated.
- ly guarantees functionality when using the original RESTUBE-CO2-Cartridge (16g / 21ml). … is not suitable for temperatures below 4°C.
- only wear Restube on top of clothing, so that the trigger is accessible and the floating device is not prevented from inflating!
- requires active use by the user and is therefore not suitable for people who are physi- cally or mentally incapable of swimming.
- has a supporting function in water, but does not provide protection in case of uncon- sciousness.
- A slight trigger delay is possible in temperatures below 59°F (15°C). Carrying additional weights or clothing reduces the perceived buoyancy of Restube.
- Make sure that supervision is nearby. Only put yourself in situations with Restube that you could handle safely without the product.
Operation and maintenance
NOTICE
- Check the product’s readiness for use (trigger and cartridge) before each use!
- Open the pocket and verify that release lever is switched to the green position
- If not, the CO2 cartridge may be empty. In this case, unscrew the CO2 cartridge
- If the cartridge is pierced at its opening, it is empty and must be replaced
- Verify that the buoy is in the correct position in the pocket
- The trigger mechanism must face the label with this symbol sewn into the pocket
How do I fasten Restube correctly
WARNING
Wearing the product loosely or open is dangerous! The product must be tightly
secured to prevent loss and enable functionality.
The provided waist strap may be inserted vertically or horizontally into the
back of the pocket.
The options for attaching the strap have different advantages for wearing the
pocket on land or for practicing water sports. The user may choose the most
suitable position depending on the application and personal preferences.
NOTICE
When using a vertical position the pocket must be worn so that the trigger
faces downward!
- Remove buckle and adjuster from waist strap
- Velcro 6b on the waist strap must face upward
- Insert the waist strap through the horizontal or vertical strap positioner (black fabric) on the back of the pocket until velcro 6b connects to velcro 6c inside of the strap positioner.
- This prevents the pocket from moving around the waist strap
- Slide buckle and buckle back on
- The X-strap on the back of the pocket allows you to insert your own straps, up to a width of 50mm.
- Insert the waist strap horizontally or vertically over the black strap positioner and under the X-strap
- Open the buckle and place the waist belt around the hips
- Wear the pocket so that the RESTUBE logo faces outward and the strap positioner rests against the body Close buckle safely
- Fasten the buckle securely and adjust the waist strap to fit tightly >>> The loose end of the waist strap can be fixed using the adjuster Wear Restube on your right, so that the trigger is easily accessible with your left hand
**Harness attachement
**
-
Attachment to the harness hook belt
The pocket may be worn vertically or horizontally, though vertically is recommended.- Remove buckle and strap adjuster from RESTUBE waist strap
- Remove RESTUBE waist strap from strap positioner
- Detach harness hook belt from harness on one side
- Insert harness hook belt into the vertical or horizontal strap positioner of RESTUBE’s X-strap system depending on its length, width, and your choice of alignment.
- The X-strap system allows you to insert harness hook belts 25, 30, 40 and 50mm wide in both directions.
- When attached vertically, the trigger must face downward
- Attach the harness hook belt to the harness as usual
- Attachment to the back of the harness with 2 safety loops
- Depending on the size of the harness, this may be done with the waist strap or with the additional strap for harness fixation for small harnesses. The pocket may be worn vertical-ly or horizontally, though horizontal attachment is recommended.
- Remove the RESTUBE waist strap from the pocket as in (1).
- Attach the buckle to the waist strap
- Pass each end of the RESTUBE waist belt through one loop
- Close the buckle
- Make sure that the trigger is easily accessible
- If this is not the case, move the pocket sideways on the harness accordingly
How do I trigger Restube?
NOTICE
Triggering and inflation is only guaranteed in water because buoyancy pulls
the buoy from the pocket! Duration until completely filled may be lengthened
when triggered on land.
- Grab the trigger with your left hand and pull away from the body firmly
- The buoy will unfold within seconds
How do I use Restube?
WARNING
Do not unscrew CO2 cartridge while in use! After triggering, the CO2 cartridge
is very cold. Avoid direct skin contact.
- Tuck fully inflated buoy under your arms
- Adopt a stable position to keep airways free
- If you need help, use the trigger as a whistle >>> You can also wave with the buoy to call attention to yourself
- Remain calm until help on site or self-help is possible
What to do if someone else needs help in the water?
WARNING
Notify professional assistance and third parties first. Do not endanger your
own safety!Restube is not intended for towing people.
- Use the RESTUBE buoy as a buoyancy aid when approaching the person in need
- The RESTUBE buoy can be transferred to the person in need if the situation requires this and both the necessary knowledge and physical condition exist
- Subsequently, further measures may be taken to assist the person
Inflating by mouth
WARNING
Never inflate the flotation device by mouth and trigger the CO2 cartridge
afterwards. This may cause over-inflation and serious damage. Never fill buoy
with other gases! Do not fill buoy with the help of an inflation device (e.g.,
pneumatic pump)! Please avoid inhaling the CO2 gas from the flotation device
when topping up the buoy via the oral valve
- Remove buoy from pocket
- Open the Velcro on the safety leash and unwrap safety leash
- Unfold buoy completely
- Open the cap of the oral valve
- Inflate buoy with your breath using the valve
How do I make Restube ready for its next use?
Once Restube has been triggered, it must be made ready to be used again. You will need an original RESTUBE-CO2-Cartridge.
NOTICE
Only the original RESTUBE-CO2-Cartridges are 100% quality-certified, seawater
resistant and the force is tailored to the RESTUBE trigger!
Do not use comparable commercial CO2 cartridges!
These will not guarantee inflation of Restube in an emergency.
The CO2 cartridge
Restube beach only guarantees functionality when using the original RESTUBE-
CO2-Cartridge (16g).
- Remove any dirt (e.g., sand)
- Unscrew the empty CO2 cartridge and dispose of with residual waste
- Fold away release lever to avoid piercing the new CO2 cartridge
- Switch the release lever to the green postition to avoid piercing the new CO2 cartridge.
- Screw the new original-RESTUBE-CO2 cartridge tightly and up to the marking into the trigger mechanism
The buoy
NOTICE
Pointed or sharp objects can damage the valve! The buoy can only be folded
away cor-rectly when there is no gas in it.
Empty the buoy completely (#2)
-
Open the cap of the mouthpiece
-
Release the gas from the buoy
-
Fully release gas by folding or rolling the buoy
-
Close the cap of the oral valve
Longitudinal fold (#3) -
Spread out the buoy so that the trigger mechanism is in the top left
-
Fold up the bottom part of the buoy along the horizontal dotted line
-
Tuck the folded part of the buoy under the CO2 cartridge so that the oral valve folds away to the left
Zigzag fold (#4) -
Turn the buoy so that the trigger mechanism is facing upward
-
Fold over the bottom end of the buoy to the back along the first solid line
NOTICE -
The words “Oben/Top/Haute/Arriba” must be visible.
-
Fold over the next part to the front along the dotted line
-
Continue until you reach the trigger
-
The buoy is correctly folded if the CO2 cartridge is on the outside
-
The last fold must be to the back
-
Wrapping the safety leash around the buoy (#5)(Wrap only once until the yellow thread ends)
-
Hold the folded buoy firmly in one hand
-
Use the free hand to wrap the safety leash exactly once around the buoy and the back end of the CO2 cartridge
-
NOTICE
-
Do not wrap the remaining safety leash further around the buoy – store it behind the CO2 cartridge in the pocket.
-
Attach the safety leash to the white velcro 6d
-
Pack away the folded buoy into the pocket
-
WARNING
-
If the buoy is not positioned correctly in the pocket, correct release is not guaranteed!
-
Position the folded buoy in the pocket so that the trigger mechanism is facing the label with this symbol
-
The trigger cord must hang out of the pocket
-
Store the rest of the safety leash in the pocket next to the cartridge
-
Close the flap of the pocket
-
Close velcro 6.a on the inside
-
Fasten the split pin on the trigger cord alternating between the front and back loops
Troubleshooting
Problem | Cause | Corrective action |
---|
Buoy does not fit into
the pocket
| | Buoy is not fully emptied| | > Empty buoy completely
Velcro does not close| | Buoy is not folded correctly Buoy is not positioned
correctly in the pocket| | > Observe packaging instructions
Trigger mechanism must face the label with this symbol
CO2 cartridge is pierced immediately when screwing in| | The release lever was
not switched before screwing in the new CO2 cartridge| | > switch the release
lever to the green postition to avoid piercing the new CO2-cartridge.
CO2 cartridge can- not be screwed in or only screwed in with much difficulty|
| Dirt on the thread or trigger mechanism| | > Clean the trigger mechanism
Storage, care, maintenance and disposal of your RESTUBE product
Lifespan & storability
RESTUBE products are designed to have a long lifespan and can be triggered
from 50 to 250(*) times, depending on the version. Once used, the device is to
be stored outside its packaging, well ventilated and at a maximum temperature
of 28°C. The maximum lifespan of the device is 5 years from the date of
purchase, assuming that the care and maintenance instructions are followed.
If used frequently (more than once per week) or in tropical climates, the
product lifespan may be shorter. If humidity is high, the device should be
removed from its box. Do not put RESTUBE products on radiators and do not dry
or store them in direct sunlight.
Care
- Maintain your RESTUBE product after every use. Five minutes of your time will help to make sure that you carry on being able to enjoy the product.
- Take the bladder out of its bag and check all parts for external damage: Bag, bladder, trigger, trigger cord and CO2 cartridge. None of the components should show signs
- of heavy use, significant rust or damage.
- Following use in saltwater or chlorinated water: Remove the bladder from its bag, and rinse both in fresh water, ensuring that the oral valve is closed and that the cartridge is screwed in first. If the product has become particularly dirty, wash it with mild detergent or a weak solution of lye and rinse it with fresh water afterwards. Do not use cleaning agents which contain alcohol or solvents.
- The bladder and its bag should be opened and hung out to dry. Once dry, pack the system back up in accordance with the packing instructions.
Maintenance
With a little care, you will be able to maintain your undamaged RETUBE product
yourself. If you are unsure about something, contact us by email:
info@restube.com.
We will be happy to carry out a check for you – all you will have to pay for
is the costs of postage and for any replacement parts which may be needed.
NOTE: Never carry out any repairs on your RESTUBE product yourself!
Maintenance intervals
At least every year, as well as before any longer periods of use.
Additionally, maintenance should also be carried out following every
inflation.
Visual check
Check all components for damage, wear or deposits: Bag & stitching, waistband
and buckle, bladder, trigger, trigger cord, CO2 cartridge and CO2 cartridge
thread (to do this, unscrew the cartridge and screw it back in again)
Trigger test
We suggest that you trigger your RESTUBE product in the water, so that you can
expe-rience the buoyancy yourself. Once back on land, unscrew the cartridge
and move the release lever as if triggering the device. The pin should move
inside the fitting for the cartridge.
Oral valve test
Remove the cap from the valve and depress the oral valve in order to allow
some CO2 to escape. Afterwards, the oral valve should be completely sealed
again. Next, empty the float entirely via the oral valve. Next, inflate the
float via the oral valve until it is firm, using only your breath to do so.
Air-tightness of the float
Having completely inflated the float by blowing into it, leave it somewhere
where the temperature is stable for 24 hours. Should it lose a lot of air
during this period, the prod-uct will need to be replaced. NOTE: Pure CO2
slowly diffuses through the material which the bladder is made of. It is
therefore normal for the float to slowly empty over a period of 15-30 hours if
it has been filled with pure CO2 from the cartridge.
Getting ready for the next use
Pack the dry RESTUBE product up according to its packing instructions. Ensure
that the old cartridge, which has been pierced and has a hole, is replaced
with a new, intact one. NOTE: Only use genuine RESTUBE CO2 cartridges, as the
inflation function can otherwise be adversely affected. The cartridges conform
to EN ISO 12402-7 as well as UL 1191. They are 1. made to fit the trigger and
have a very thin pierceable cap, 2. weighted for the exact amount needed to
fill the bladder and 3. are very resistant to sea water.
Disposal
- Bag and belt can be disposed of in the general waste. The CO2 cartridges can only be disposed of in the general waste if they are empty.
- Help us to make everyone freer and safer in the water!
- Show other water-lovers how you use your Restube. Post a picture of yourself with a Restube on Facebook or Instagram, link to @restube.official and #restubemoment and write about your special RESTUBE experience. We look forward to hearing from you!
- Thanks for your help, the RESTUBE team
References
- RESTUBE - the airbag for more freedom and safety in the water | RESTUBE
- Restube extreme - the buoy for rough conditions | RESTUBE
- Restube extreme - the buoy for rough conditions | RESTUBE
- Frequently asked questions - RESTUBE | RESTUBE
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>