- The product is dimmable by wireless control. DO NOT use a wall dimmer.
- Operate with ElectroMagnetic (EM) ballasts or direct mains only. The product is NOT compatible with high-frequency electronic ballast.
- Note: 600mm product is not intended for series operation.
- The product must be used in a dry environment and in luminaires that are approved for the application.
- Operating ambient temperature from -20°C to +45°C.
- Must be used with compatible control devices.
- The product should be used within a specified radio-frequency (RF) communication range.
This range can vary depending on the actual application environment.
SYMBOL | MEANING |
---|---|
DO NOT USE WITH DIMMERS | |
LAMP SUITABLE FOR 50Hz OR 60 Hz OPERATION | |
NEED TO BE USED WITH LED REPLACEMENT STARTER EMP | |
NEED TO BE USED IN DRY CONDITIONS OR IN A LUMINAIRE THAT PROVIDES PROTECTION | |
LAMP NOT SUITABLE FOR EMERGENCY OPERATION |
THIS LAMP IS NOT SUITABLE TO BE USED IN EMERGENCY LUMINAIRES DESIGNED FOR DOUBLE-CAPPED FLUORESCENT LAMP(S).
Follow the instructions below to install the product(s). Different systems may require the physical installation of devices at different stages during system setup. You’re required to read the system guide to understand the complete and proper sequence.
For lamps that work on ElectroMagnetic (EM) ballast
- No modifications of the luminaire which the LED lamp is to be used with are to be made.
- This lamp may not be suitable for use in all applications where a traditional fluorescent lamp has been used. The temperature range of this lamp is more restricted. In cases of doubt regarding the suitability of the application, the manufacturer of this lamp should be consulted.
- This lamp is designed for general lighting service (excluding e.g. explosive atmospheres).
For lamps that work on High Frequency (HF) electronic ballast
- In this application, an LED replacement starter is not used.
- Always switch off the power supply before commencing work!
- Philips LED tubes should be installed by qualified professionals in accordance with the relevant code.
- Stick the Warning Sticker on the luminaire after the modifications have been made.
After powering on, lamps will automatically search for available Zigbee
networks and connect to a Zigbee gateway (if any). Lamps can also be
commissioned by using a designated Bluetooth mobile application. Please refer
to our website for instructions on app download.
When needed, performing a factory reset will restore a lamp to its default
state. The lamp will be removed from its current network (if any) and all
settings will be deleted.
- The lamps can be reset from the system app when credentials are properly kept and lamps are accessible. In this case please follow the in-app instructions.
- If credentials are lost, lamps will need to enter safe mode in order to be reset. Turn the lamps off for 5 seconds, then on for 5 seconds. Repeat 5 times to activate the safe mode. Visit our website to download the tool for factory reset.
Hereby, Signify declares that the radio equipment is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is
available at the following internet address:
www.philips.com/lighting
Wireless RF mode Frequency Range: Bluetooth Low Energy: 2402-2480 MHz, Zigbee:
2405-2480 MHz Output power (Conducted): Bluetooth Low Energy: 4dBm, Zigbee:
4dBm
The Bluetooth word and logos are registered trademarks owned by Bluetooth SIG,
INC.
All rights reserved. Reproduction in whole or in part is prohibited without
the prior written consent of the copyright owner
The information presented in this document does not form part of any quotation
or contract, is believed to be accurate and
reliable, and may be changed without notice. No liability will be accepted by
the publisher for any consequence of its use.
Publication thereof does not convey nor imply any license under patent or
other industrial or intellectual property rights.
Philips and the Philips Shield Emblem have registered trademarks of
Koninklijke Philips N.V.
Signify LB.RS./C.C.RI. Num~r 1046
600VB Eindhoven, the Netherlands
00800-74454775
www.philips.com/lighting
0 2020 Signify Holding
@Signify
Documents / Resources
|
PHILIPS Mains T8 MasterConnect LEDtube
Light
[pdf] Installation Guide
Mains T8 MasterConnect LEDtube Light, Mains T8, MasterConnect LEDtube Light,
LEDtube Light, Light
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>