Rasonic R410A Window Type Air Conditioner User Manual

June 5, 2024
Rasonic

Rasonic-LOGO

Rasonic R410A Window Type Air Conditioner

Rasonic-R410A-Window-Type-Air-Conditioner-image

Read This Manual
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting.
Tips first, you may not need to call for service at all.

CAUTION

Contact the authorised service technician for repair or maintenance of this unit. Contact the installer for installation of this unit.
Installation work must be performed in accordance with the national wiring standards by authorised personnel only.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play the appliance. Cleaning and user maintenance shall not be made by children without supervision. ( EN Standard requirements )
This appliance is not intended for use by persons (including children) with reduced physical , sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. (IEC Standard requirements )
Children should be supervised to ensure that they do not play with the appliance.
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
The appliance shall be installed in accordance with national wiring regulations.
Do not operate your air conditioner in a wet room such as a bathroom or laundry room. The appliance with electric heater shall have at least 1 meter space to the combustible materials.
Contact the authorised service technician for repair or maintenance of this unit.

SAFETY PRECAUTIONS

To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage.
The seriousness is classified by the following indications.

WARNING
This symbol indicates the possibility of death or serious injury.
CAUTION
This symbol indicates the possibility of injury or damage to property.

Meanings of symbols used in this manual are as shown below

WARNING

  • Plug in power plug properly.
    • Otherwise, it may cause electric shock or fire due to excess heat generation.
  • Do not operate or stop the unit by inserting or pulling put the power plug.
    • It may cause electric shock or fire due to heat generation.
  • Do not damage or use an unspecified power cord.
    • It may cause electric shock or fire.
    • If the power cord is damaged, it must be replaced by the manufacturer or an authorised service centre or a similarly qualified per- son in order to avoid a hazard.
  • Do not modify power cord length or share the outlet with other appliances.
    • It may cause electric shock or fire due to heat generation.
  • Do not operate with wet hands or in damp environment.
  • Do not direct airflow at room occupants only.

CAUTION

  • When the air filter is to be removed, do not touch the metal pats of the unit.
    • It may cause an injury.
  • Do not clean the air Conditioner with water.
    • Water may enter the unit and degrade the insulation. It may cause an electric shock.
  • Ventilate the room well when used together with a stove, etc.
    • An oxygen shortage may occur
  • When the unit is to be cleaned, switch off, and turn off the circuit breaker
    • Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury.
  • Do not put a pet or house plant where it will be exposed to direct air flow.
    • This could injure the pet or plant.

SAFETY PRECAUTION

Preparing for operation

  1. Contact an installation specialist for installation.
  2. Plug in the power plug properly.
  3. Do not use a damaged or non-standard power cord.
  4. Do not share the same outlet with other appliances.
  5. Do not use an extension cord.
  6. Do not start/stop operation by plugging/unplugging the power cord.

Usage

  1. Exposure to direct airflow for an extended period of time could be hazardous to your health. Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
  2. Due to the possibility of oxygen deficiency, ventilate the room when used together with stoves or other heating devices.
  3. Do not use this air conditioner for non-specified special purposes (e.g. Preserving precision devices, food, pets, plants, and art objects). Usage in such a manner could harm such property.

Clearing and maintenance

  1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges.
  2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
  3. When cleaning the unit, first make sure that the power and circuit breaker are turned off.

Operating Temperature

Cooling operation

Rasonic-R410A-Window-Type-Air-Conditioner-fig28

Note: Performance may be reduced outside of these operating temperatures.

  1. Power cord conductors are distinguished according to color as follows (see Fig.1)
  2. For your safety and protection, this unit is earthed through the power cord (see Fig.2) Please contact the manufacturer or its service agent or a similar qualified person if you want to replace it.
  3. Be sure that the unit being correctly grounded. The wall outlet (Air-break switch)should be provided with reliable earth wire.
  4. The unit should be provided with an individual circuit and the circuit breaker/fuse rating should be the same as that of the power cord and wall outlet.Rasonic-R410A-Window-Type-Air-Conditioner-fig1

UNIT PARTS IDENTIFICATION

NOTE: The front panel and cabinet may be sl ight ly different according to the models, but the funct ions are the same. The fol lowing il lustration is for explanat ion purpose only , the actual shape of the machine you purchased may be sl ight ly di fferent.Rasonic-R410A-Window-Type-Air-
Conditioner-fig2

  1. Front panel
  2. Air filter
  3. Frame
  4. Cabinet
  5. Air inlet grille (outdoor side)
  6. Air outlet grille
  7. Electronic control keypad
  8. Power supply cord
  9. Control panel cover
  10. Remote control
Accessories

Rasonic-R410A-Window-Type-Air-Conditioner-fig3

NOTE: All the illustrations in the manual are for explanation purpose only.Your air conditioner may be slightly different.The actual shape shall prevail.

OPERATING INSTRUCTIONS

Control

The electronic control keypad will look like one of the following:Rasonic-
R410A-Window-Type-Air-Conditioner-fig4 NOTE: The outline of the operation panel is based on typical model, the function is the same with your air conditioner while some difference may exist in appearance. LED shows the intake temperature.

Vent Control

The vent control is located above the control knobs. The operation method is different on different models (see the following figures).
For maximum cooling efficiency, CLOSE the vent. This will allow internal air circulation. OPEN the vent to discharge stale air. To open the vent, pull the lever toward you To close it, push it in. To open the vent, set the lever to the right position To close it, set the lever in the left position.

OPERATION INSTRUCTION

POWER
Press the POWER keypad to turn the unit on/off. (The TIMER keypad controls the auto start/stop feature of the unit.)

MODE
Press the “MODE” keypad to select the appropriate operating mode. The mode selection will alternate between AUTO, HEAT, COOL, FAN and DRY. The green indicator light beside the “MODE” option will illuminate, identifying the mode selected.
When using the DRY and AUTO mode, you cannot select a fan speed. The fan motor operates on LOW speed in DRY mode and on MED speed in AUTO mode.Some models wihtout MED speed,the fan motor operates on HIGH speed in AUTO mode.

TEMPRATURE UP SETTING
Press the keypad to increase the set (operating) temperature of the unit. Each time the keypad is pressed the temperature increases as follows: 1 C (Celsius Scale) Maximum Setting 30 C

TEMPRATURE DOWN SETTING
Press the keypad to decrease the set (operating) temperature of the unit. Each time the keypad is pressed the temperature decreases as follows: 1 C (Celsius Scale) Minimum Setting 17 C

FAN
Press this keypad to activate the appropriate fan speed setting. Each depression of the keypad will alternate through LOW, MED(some models without), HIGH fan speed options. The green indicator light beside the FAN speed option will illuminate, identifying the fan speed selected

SWING
Press the “SWING” keypad to activate the automatic air swing (oscillation) feature. The green indicator light adjacent to the “SWING” keypad will illuminate, identifying to the selected mode is operational. The vertical louvers will oscillate back and forth (side to side) automatically sweeping air alternately for comfortable cooling. To stop the air swing feature, press the “SWING” keypad again, the green indicator light adjacent to the keypad will go off. Press the “SWING” keypad for 2 seconds will activate the SLEEP mode which can reduce noise creating a comfortable sleeping environment.
When the SLEEP mode is activated, the green indicator light beside the “SLEEP” function will illuminate.

TIMER
Press the “TIMER” keypad to activate the “auto start/auto stop” timer function.
Auto start/stop programs can be set from 0~24 hours. Each depression of the “TIMER” keypad will increase or decrease the selected time in 0.5 hour increments up to 10 hours, then by 1 hour increments up to 24 hours.

DRY
In the Dry mode, the air conditioner will generally operate in the form of a dehumidifier.
Since the conditioned space is a closed or sealed area, some degree of cooling will continue.
COOLING
The temperature setting are adjustable between 17 C to 30 C .

HEATING
The temperature setting are adjustable between 17OC to 30OC .

AUTO
The unit will select the appropriate operating mode from Fan, Cool or Heat based upon the temperature difference between the actual and desired room temperature. If the actual room temperature is 2OC above the set point, the unit operates in cooling mode. When the actual room temperature is 1OC higher above the set point but 2OC lower below the set point, the unit will select the Fan mode. When the actual room temperature is 2OC below the set point, the unit will operate in Heat mode.
Note: If activating the SLEEP mode when the unit is operating on AUTO mode, the fan motor will changed into LOW speed mode immediately.

ECONOMY (SLEEP)
For the models with SWING feaure, press and hold the “ECONOMY” keypad for 2 seconds or use the remote control to activate the “ECONOMY” feature.
Press and hold the “SWING” keypadfor 2 seconds again or use the remote control again to deactivate the “ECONOMY(SLEEP)” feature. For units without “SWING” feature, use
the remote control to activate the “ECONOMY(SLEEP)” feature.
In the Cooling mode, the cooling temperature set point will increase 1 C per hour after the “ECONOMY(SLEEP)” mode is selected. Two hours later , the set point will continue at this temperature and the fan motor will remain on OW speed.
In the Heating mode, the heating temperature set point will decrease 1OC per hour after the “ECONOMY(SLEEP)” mode is selected. Two hours later, the set point will continue at this temperature and the fan motor will remain on LOW speed.
Using the “ECONOMY(SLEEP)” mode will reduce noise creating a comfortable sleeping environment.
Note: This feature is not available under DRY and FAN ONLY operation.

Failure Indicator Display :

Er: Indicates a malfunction of the indoor room temperature sensor
En: Indicates a malfunction of the evaporator temperature sensor
Eo: Indicates a malfunction of the outdoor condenser temperature sensor
Ed: Indicates frosting protection (Turn off the unit and restart it to return to normal operation)

Note: When one of the above malfunctions occurs, turn off the unit, and check for any obstructions. Restart the unit, if the malfunction is still present, turn off the unit and unplug the power cord. Contact Shun Hing Electric Service Centre Ltd hotline at 2406 5664.

CAUTION
NEVER operate the air conditioner without the air filter, as dust/dirt particles can contribute to equipment failure.

CONTROL PANEL COVER

Grasp the right of the control panel cover and pull it upwards to open it .
Close the control panel cover and press the right of the cover again until it snaps into the locked position.

AIR FILTER

The air filter behind the inlet grille should be checked and cleaned at least once every 2 weeks (or as necessary) to maintain optimal performance of the air conditioner.

How to remove the air filterRasonic-R410A-Window-Type-Air-Conditioner-
fig9

  1. Hold the tabs under the front panel, then uplift it outwards, and remove the front panel.
  2. Pinch the handle under the air filter and make the air filter arched, remove it from the slot from underside to upside.
  3. Clean the filter with warm, soapy water. The water should be below 40OC to prevent distortion of the filter.
  4. Rinse off and gently shake off excess water from the filter. Allow the filter to dry before replacing it. To prevent distortion of the filter, do not dry in direct sunlight.

Vertical airflow adjustment (manually)

To adjust vertical air flow direction of the up or low horizontal louvers, adjust any one of the up or low horizontal louver blades. Rasonic-R410A-
Window-Type-Air-Conditioner-fig10

Drainage

To meet different requirement of different type of air conditioner, there are three kinds of methods for your choice to treat the condensed water.
See the following procedures to perform back drainage:

  1. Fit the seal onto the drain joint (which provided with your air conditioner accessory).
  2. Remove the rubber plug from the back of the unit (If applicable),and insert the rubber plug (which provided with your air conditioner accessory) into the bottom drain hole of the unit.
  3. Attach the drain joint to the back of the cabinet where you remove the plug and rotate 90 to securely assemble them.
  4. Connect the drain joint with a extension drain hose .(Please buy yourself)
    Note:
    If you choose non-drainage,both the bottom and the back drain hole of the unit should be inserted with the rubber plug.

See the following procedures to perform bottom drainage:

  1. Remove the rubber plug from the bottom of the cabinet and attach to the back drain hole. For the units without the bottom rubber plug, just install the drain tray.
  2. Take out the drain tray and screws (which provided with your air conditioner accessory).
  3. Install the drain tray at the bottom of the unit and secure with screws provided.
  4. Connect the drain hose to the outlet located at one side of the drain tray. You can purchase the drain hose or tubing locally to satisfy your particular needs .
    Suggestion: To ensure the condensed water drain off smoothly, always keep the drain oulet of the the drain tray downward when install the drain tray.

INSTALLATION INSTRUCTION

Select the best location

Rasonic-R410A-Window-Type-Air-Conditioner-fig13

  1. To avoid vibration and noise, make sure the unit is installed securely and firmly.

  2. Install the unit where the sunlight does not shine directly on the unit.
    If the unit receives direct sunlight, build an awning to shade the cabinet.

  3. There should be no obstacle, such as a fence or wall, within 50cm from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling and heating efficiency of the air conditioner.

  4. Install the unit a little obliquely outward not to leak the condensed water into the room (about 1Omm or 1/4 bubble with level).

  5. Install the unit with its bottom portion 75-150cm above the floor level.

  6. The power cord must be connected to an independent circuit. The yellow/green Wire must be grounded.

installation of the housing
  • Step 1
    Remove the air conditioner from it’s packaging, remove fixing  Screws and slide the air conditioner out of it’s housing (Referto Installation Steps).

  • Step 2
    Prepare the hole in the wall so that the bottom of the housing is well supported, the top has minimum clearance and the air inlet louvers have clearance as shown below in options AandB. Holes from the outside through to the cavity should be  sealed. The housing should slope down towards the rear byabout 5mm to allow water formed during operation to drain.

  • Step 3
    Install the housing into the wall and secure. Ensure the foam seals are not damaged. Flash, seal or fill gaps around the inside and outside to provide satisfactory appearance and protection against the weather, insects and rodents.

installation of the unit into the housing

  1. Slide the unit into the housing until it is firmly against the rear of the housing. Care is required to ensure the foam sealing strips on the housing remain in position.
  2. Connect the air conditioner to the power and position excess cord length beneath the air conditioner base.
  3. Engage the chassis fixing brackets into the bottom housing rail and secure to the base with the screw provided.
  4. Remove the front panel from it’s carton and plastic bag and fit as per the Installation Instruction.
  5. Switch unit on. Check for operation of the unit and check for vibration in the installation.
  6. Fit the drain pan to the housing and run a drain line to a suitable location if required.

installation of the unit into the wall

Rasonic-R410A-Window-Type-Air-Conditioner-fig16

Installation steps
  • Step 1. Remove the front panel and the air filter
1. Hold the tabs under the front panel, then uplift it outwards, and remove the front panel (See Fig.1).
2. Pinch the handle under the air filter and make the air filter arched, remove it from the slot from underside to upside (See Fig.2).
  • Step 2. Remove the frame.
1. Remove the two fixing screws from the frame (See Fig.3).
2. Grasp the left corner of the frame’s underside, release the coupler plugs, then loosen the frame (See Fig.4).
  • Step 3. Installation.
1. Remove the two fixing screws on the chassis fixing brackets, then remove the chassis fixing brackets (See Fig.5).
2. Grasp the handle on the chassis and carefully slide the air conditioner out of the cabinet (See Fig.6).
3. Remove shipping pad from around compressor before operation and make sure the discharge points to the drain pan are aligned before the chassis is pushed into the cabinet (See Fig.7).
4. Push the unit chassis into the cabinet (See Fig.8).
5. Install the two chassis fixing brackets using the two fixing screws (See Fig.5).
  • Step 4. Install the frame.
1. Install the frame and connect the coupler plugs, making sure not to interfere with the temperature sensor cable (See Fig.9).
2. Fix the screws on the frame (See Fig.3).
  • Step 5. Install the air filter and front panel.
    1. Install the air filter into the frame’s slot from upside to underside (See Fig.2).
    2. Hang the front panel on the frame’s buckle, then press the front panel into the frame’s slot until you hear a click (See Fig10).

TROUBLESHOOTING

Troubleshooting tips

Save time and money! Review the chart below first and you may not need to call for service.

Normal Operation

  • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency.
  • You may hear the thermostat click when the compressor cycles on and off
  • Water will collect in the base pan during high humidity or on rainy days .The water may
  • Overflow and drip from the outdoor side of the unit.
  • The fan may continue to operate when the compressor has cycled off.

Rasonic-R410A-Window-Type-Air-Conditioner-fig29

SPECIFICATION

Model| Cooling Capacity

(Btu/h)

| Unit Dimension(mm)

(W x H x D)

| Wirning Size

(m m2 )

---|---|---|---

RC-X7KM

|

7000

|

450x346x585

|

3*1.5

RC-X9KM

| 9000| 450x346x585| > 3*1.5

Special Avowal

  1. The information above has been checked; our company reserves the hermeneutic power to any print errors or misunderstanding on the content.
  2. Any technology improvement will add into new instruction without any prior notices. The product appearance and color refer to the practical air conditioner.

After sale service
Guarantee period state from the date of purchasing to one year. If the product is damaged under proper use, a free repair service is available. Please present the official invoice and the guarantee certificate with the sales point’s chop / redemption center’s chop for free maintenance. For enquiries, please contact Shun Hing Electric Service Centre Limited hotline at 2406 5666.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals