KLARSTEIN 10030822 Madonna Bonita Range Hood Instruction Manual

June 5, 2024
Klarstein

KLARSTEIN 10030822 Madonna Bonita Range Hood Instruction Manual
KLARSTEIN 10030822 Madonna Bonita Range Hood

Dear Customer,
Congratulations on purchasing this device. Please read the following instructions carefully and follow them to prevent possible damages. We assume no liability for damage caused by disregard of the instructions and improper use.

Scan the QR code to get access to the latest user manual and more product information.
QR Code Icon

TECHNICAL DATA

Item number 10030822, 10030823
Power supply 220-240 V ~ 50/60 Hz

Note: You can purchase an activated carbon filter separately for this cooker hood under item number 10031626. Please visit our website: www.hifi- tower.co.uk

SAFETY INSTRUCTIONS

  • Thank you for purchasing this cooker hood. Please read the instruction manual carefully before you use the cooker hood, and keep it in a safe place.
  • The installation work must be carried out by a qualified electrician or competent person. Before you use the cooker hood, make sure that the voltage (V) and the frequency (Hz) indicated on the cooker hood are exactly the same as the voltage and the frequency in your home.
  • The manufacturer and the agent will not bear any responsibility for the damage caused by inappropriate installation and usage.
  • Children under the age of 8 must not use the cooker hood.
  • The appliance is not intended for commercial use, but only for household and similar environments.
  • The cooker hood and its filter mesh should be cleaned regularly in order to keep it in good working order.
  • Before cleaning, switch the power off at the main supply.
  • Clean the cooker hood according to the instruction manual and keep the cooker hood from the danger of burning.
  • Prohibit putting the cooker hood by fire.
  • If the appliance does not function normally, contact the manufacturer or a specialist company.
  • This device may be only used by children 8 years old or older and persons with limited physical, sensory and mental capabilities and / or lack of experience and knowledge, provided that they have been instructed in use of the device by a responsible person who understands the associated risks.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
  • If the range hood is used at the same time as appliances burning gas or other fuels, the room must be adequately ventilated.
  • Do not flambé under the range hood. Accessible parts may become hot when used with cooking appliances.

Important hints on installation

  • The air must not be discharged into a flue that is used for exhausting fumes from appliances burning gas or other fuels (not applicable to appliances that only discharge the air back into the room).
  • Regulations concerning the discharge of air have to be fulfilled.

Important notes about the extraction mode

WARNING
Risk of poisoning from exhaust gases sucked back. Never operate the device in extraction mode simultaneously with an open flue appliance when there is not adequate airflow guaranteed.

Open flue combustion equipment (for example, gas, oil, wood or coal-fi red heaters, tankless water heaters, water heaters) pulls combustion air from the room and runs it through an exhaust pipe or chimney to the outside. In the extraction mode, indoor air is removed from the kitchen and the adjacent rooms without sufficient air intake this creates a vacuum. Toxic gases from the chimney or extraction flue can thereby be sucked back into the living spaces.

  • Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
  • An air supply / extractor box alone does not ensure compliance with the limit value.

Safe operation is only possible when the negative pressure in the room where the appliance is located does not exceed 4 Pa (0.04 mbar). This can be achieved when the air required for combustion can flow through openings that are not closable, for example in doors, windows, in conjunction with an air supply / extractor box or through other technical measures. In any case, consult a qualified chimney sweep who can assess the entire ventilation of your house and propose appropriate measures for adequate ventilation.

If the hood is used exclusively in the recirculation mode, unrestricted operation is possible.

Important note on disassembly of the device

  • Disassembly is similar to installation/assembly in reverse order.
  • Take a second person to help you during disassembly to avoid injuries.

INSTALLATION

  1. The ceiling from which the unit is suspended must be able to support at least 40 kg of weight and must be at least 30 mm thick. Drill a 170 mm hole in the ceiling. 2.

  2. Drill 12 holes in the ceiling as shown in Figure 2 and fix the suspension with 640 mm screws. Use 8 M410 bolts and M4 gasket nuts with gasket to attach the iron angle to the suspension. After calculating the length of the iron angle (see Fig. 1), use 16 M4*10 bolts and M4 gasket nuts to attach one more iron angle to the iron angle. The angles must overlap by at least 10 cm!
    INSTALLATION

  3. Pass one end of the exhaust hose through the hole in the ceiling (see Figure 3).

  4. Use 4 ST4*8 screws to fi x the internal chimney (see picture 4). To install the external chimney, you need the hooks shown in picture 4.

  5. Use 4 ST4*8 screws to fi x the external casing (see picture 5).
    INSTALLATION

  6. Hold the exhaust hood up and fasten it with 16 M4*10 screws (see Fig. 6).

  7. Attach the exhaust hose to the air outlet (see Fig. 7).
    INSTALLATION

  8. Make sure everything is properly seated, remove the hooks from the external chimney to complete the installation (see Figure 8).

INSTALLATION OF AN ACTIVATED CARBON FILTER

Note: The activated carbon filter is NOT included and must be purchased separately!

Activated carbon filters are used to bind odors. Typically, the activated charcoal filter should be changed after three or six months, depending on how often you cook. Install the activated carbon filter is as follows:

  1. First remove the aluminum filter to be removed first. Open the latch and remove it.
  2. Insert the activated carbon filter into the device and turn it counterclockwise. Repeat the same on the other side.
    INSTALLATION OF AN ACTIVATED CARBON FILTER

CONTROL PANEL

Model 10030823

CONTROL PANEL


1| OFF| Turn off the ventilation with this button.
2| Fan low level| Use the low level to ventilate the kitchen. It is suitable for simmering and cooking without much steam. Press again to turn off the fan.
3| Fan medium speed| The medium level is ideal for normal cooking. Press again to turn off the blower.
4| Fan high level| Select the high level when heavy smoke or steam is produced to achieve the highest exhaust efficiency. Press again to turn the blower off.
5| Light| Switching the lamp on and off.

Model 10030822

CONTROL PANEL


1| Timer| This is a 9-minute timer. Press the key during operation to start the timer. The display counts down from 9 to 0. When the display shows 0, the unit will turn off after 30 seconds unless another key is pressed. The display backlight will also go out. Note: The timer has no effect on the 2 lamps, you must turn the lamps off manually.
2| Light| Press the key to switch on the light. The indicator light turns on. Press the button again to turn the light off.
3| Speed| The motor has 3 speed levels: Low > Medium > High. When the unit is running, the display shows 1. Press the key to switch to the medium speed. Press the key again to switch to high speed. Press the key again to switch back to low speed.
4| On/Off| When you connect the device, the display lights up briefly and the device switches to standby mode. If you do not press any button for 30 seconds, the light will turn off automatically. If you want to stop the fan during operation, press this button.

CLEANING AND MAINTENANCE

Turn off the cooker hood before cleaning and maintenance and unplug the appliance from the wall outlet. The exterior surfaces are susceptible to scratches and stains. Therefore, do not use abrasive cleaners and wipe away any alkaline or acidic residue (lemon juice, vinegar) immediately after cleaning.

Stainless Steel Surfaces
The stainless steel must be cleaned regularly to ensure a long service life. Use stainless steel cleaner. Always wipe along the grain of the stainless steel to prevent scratching.

Control Panel

The control panel can be cleaned with a damp cloth and a mild dishwashing detergent. Before cleaning, make sure the cloth is clean and well wrung. Use a dry, soft cloth to remove excess moisture after cleaning.

Monthly Cleaning for Grease Filter

Clean the filter every month can prevent any risk of fire. The filter collects grease, smoke and dust, so the filter is directly affecting the efficiency of the cooker hood. If not cleaned, the grease residue (potential flammable) will saturate on the filter. Clean it with household cleaning detergent.

TROUBLESHOOTING

Fault Possible Cause Solution
Light on, but motor does not work. The leaf blocked. Get rid of the

blocking.
The capacitor damaged.| Replace capacitor.
The motor jammed

bearing damaged.

| Replace motor.
The internal with of motor off or a bad smell from the motor.| Replace motor.
Light does not work, motor does not work.| Light damaged.| Replace lights.
Power cord looses.| Connect the wires as per the electric diagram.
Shake of the body.| The leaf damaged and

causes shaking.

| Replace the leaf.
The motor is not tightly

hanged.

| Lock the motor tightly.
The body is not tightly

hanged.

| Fixed the body tightly.
Insufficient suction.| The distance between the body and the gas top too long.| Readjust the distance.
Too much ventilation from open doors or windows.| Choose a new place and resemble the machine.

PRODUCT DATA SHEET

Information according to Regulation (EU) No. 65/2014
Measurement and calculation methods according to EN 61591:1997+A1:2006+A2:2 011+A11:2014+A12:2015

Item number 10030822, 10030823
Description Symbol
Annual Energy Consumption AEChood
Energy Efficiency class  
Fluid Dynamic Efficiency FDEhood
Fluid Dynamic Efficiency class  
Lighting Efficiency LEhood
Lighting Efficiency class  
Grease Filtering Efficiency GFEhood
Grease Filtering Efficiency class  

air flow at minimum and maximum speed in normal use, intensive or boost excluded|  | 349,2 / 593,3| m³/h
air flow at intensive or boost

setting

|  | –| m³/h
airborne acoustical A-weighted sound power emissions at minimum and maximum speed available in normal use|  | 63 / 73| dB
airborne acoustical A-weighted sound power emissions at intensive or boost setting|  | –| dB
power consumption in off mode| Po| –| W
power consumption in standby

mode

| Ps| 0| W
Contact details| Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany

Information according to Regulation (EU) No. 66/2014
Measurement and calculation methods according to EN 61591:1997+A1:2006+A2:2 011+A11:2014+A12:2015

Item number 10030822, 10030823
Description Symbol
Annual Energy Consumption AEChood
Time increase factor f
Fluid Dynamic Efficiency FDEhood
Energy Efficiency Index EEIhood
Measured air flow rate at best efficiency point QBEP

Measured air pressure at best

efficiency point

| PBEP| 365| Pa
Maximum air flow| Qmax| 616,1| m³/h
Measured electric power input at

best efficiency point

| WBEP| 129,8| W
Nominal power of the lighting

system

| WL| 8| W
Average illumination of the lighting system on the cooking surface| Emiddle| 246| Lux
Measured power consumption in

standby mode

| Po| –| W
Measured power consumption

off mode

| Ps| 0| W
Sound power level| LWA| 73| dB
Contact details| Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany

NOTES ON ENVIRONMENTAL PROTECTION

  • During cooking, make sure that there is sufficient air supply so that the cooker hood can operate efficiently and with low operating noise.
  • Adjust the fan speed to the amount of steam produced during cooking. Use the intensive mode only when necessary. The lower the fan speed, the less energy is consumed.
  • If large amounts of steam are produced during cooking, select a higher fan speed in good time. If the cooking steam has already dispersed in the kitchen, the cooker hood must be operated longer.
  • Switch off the cooker hood when you no longer need it.
  • Switch off the lighting when you no longer need it.
  • Clean the filter at regular intervals and replace it if necessary to increase the effectiveness of the ventilation system and prevent fire hazards.
  • Always put the lid on when cooking to reduce cooking steam and condensation.

DISPOSAL CONSIDERATIONS

If there is a legal regulation for the disposal of electrical and electronic devices in your country, this symbol on the product or on the packaging indicates that this product must not be disposed of with household waste. Instead, it must be taken to a collection point for the recycling of electrical and electronic equipment. By disposing of it in accordance with the rules, you are protecting the environment and the health of your fellow human beings from negative consequences. For information about the recycling and disposal of this product, please contact your local authority or your household waste disposal service.

MANUFACTURER & IMPORTER (UK)

Manufacturer:
Chal-Tec GmbH, Wallstrasse 16, 10179 Berlin, Germany.

Importer for Great Britain:
Chal-Tec UK limited Unit 6 Riverside Business Centre Brighton Road Shoreham- by-Sea BN43 6RE United Kingdom

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals