LED s light B07Q72CJ4K proventa Universal Lighting Dimmer Instruction Manual
- June 4, 2024
- LED s light
Table of Contents
- LED’s light
- Universal-Dimmer
- Art.-Nr.: 190010
- Installation manual
- Thermal overload protection
- Short circuit protection
- Electrical specifications
- Normal operation
- Installation
- Connectionplan
- ON/OFF switch circuit:
- 2-way switch circuit:
- Setting the minimum Brightness (A)
- Setting operating mode (B)
- IMPORTANT NOTE !
- compatible loads
- Notes on Disposal
- Care
- Safety
- Electrical safety
- Warning
- Disclaimer
- CE declaration
- Notes
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LED’s light
CONTROL
Universal-Dimmer
for leading/trailing edge, dimmable incandescent, halogen and LED lamps
Art.-Nr.: 190010
Manual
Installation manual
important!
It is dangerous if people without proper training work on an electrical
installation.
These should only be carried out by a qualified electrician.
This dimmer must be protected on the installation side with a circuit
breaker that complies with the regulations.
Warning : electrocution hazard
There may be a dangerous voltage at the output of the dimmer!
When working on the wiring always switch off the mains voltage. Failure to
observe this warning may result in death or serious injury.
Note:
Operating at elevated temperatures or voltages may activate thermal
protection.
In this case reduce the connected load to avoid this again.
Thermal overload protection
lintegrated thermal protection circuit. At a dimmer internal temperature of
110 ° c
The over-temperature protection is triggered and remains activated until the
temperature reaches approximately 75 ° C has dropped. If this happens more
often, please reduce the load.
Short circuit protection
As soon as it is activated, the dimmer will interrupt the operation. After about 5 seconds, the dimmer is reactivated. If a fault is still detected afterwards, the dimmer interrupts the operation until you switch it off by switching it off and switching it back to normal operation. In case of failure, have the installation checked by an electrician.
Properties:
- Suitable for ON / OFF or AC switching
- Minimum load 3-5 W with capacitive or resistive load such as dimmable LED lighting, incandescent lamps, high-voltage halogen and low-voltage halogen lamps with electronic transformer.
- Soft-start operation to extend the life of the lamps.
- User setting for the lower brightness value.
- Built-in short-circuit protection, which ensures that the dimmer is protected even in the event of a wiring error or fault
- Built-in thermal cut-out to protect the dimmer at high operating temperature caused by overload.
- Meets CE and international safety standards.
Electrical specifications
Parameter | Values |
---|---|
Voltage frequency | 230-240V – 50Hz |
maximum load | LED: 200W (PF0,5) |
LED: 300W (PF0,9) | HAL/INC: 400W |
Dimming technology | |
trailing edge compatible load |
LED dimmable
| Dimmable LED lamps with compatible electronic transformator
| Standard filament lamps, High-voltage halogen lamps
| Low-voltage halogen lamps with electronics transformer
Leading-edge compatible load
Must be set manually (see next page)| | Low-voltage halogen lamps
with magnetic transformer
operating temperature| 0° – 45°C
Allowed humidity| 10-90% R.H.
mounting frame| 82m EU mounting frames
safety standard compatible| IEC EN 60669-2-1 : 2013
EMC standard compatible| IEC EN 60669-2-1 : 2002 + A1: 2008+ A2:2015
Except when used with electronic loads
Normal operation
Press knob to turn ON / OFF.
Turn the knob to the right to increase the brightness to the maximum value. Turn the knob to the left to reduce the brightness to minimum.
Installation
Wiring details
- Disconnect the power supply and secure it against reconnection.
- Remove the existing wall switch.
- Connect the dimmer according to the wiring diagram.
- Mount the cover frame and put the dimmer knob on the shaft.
- Turn power back on and test dimmer function.
Note:
The dimmer must always be connected to the phase side of the load.
Dimmers MUST NOT be connected in parallel or in series to a load.
Connectionplan
ON/OFF switch circuit:
2-way switch circuit:
Problems with dimming? For example:
- flickering
- Occasional brightness fluctuations
- Lamp at lowest dimming level too bright
Setting the minimum brightness usually leads to a perfect dimming result.
Setting the minimum Brightness (A)
- Remove the front panel cover, turn on the lamp (full brightness)
- Press the button „Min. brightness set (A)”. The lamp is now half bright.
- Now adjust the brightness down to the desired level of the basic brightness.
- Then again the button „Min. brightness set (A)”. The lamp now returns to full brightness. The setting has been saved.
Note:
The setting must be made within 10 seconds, otherwise the program will be
terminated and the setting must be carried out again.
Setting operating mode (B)
The setting is made via the rotary knob „mode Set (B)” (switch off mains voltage before setting).
There are 3 operating modes selectable:
- ‘TEauto” (factory setting) Trailing edge auto load (i.e. devices and lamps) detection, Applicable for most LED lamps.
Attention ! A common (simultaneous) operation of loads with leading-edge and loads with trailing-edge is not possible
- “TE” (Trailing Edge Mode) suitable for the operation of Loads that are to be dimmed with Trailing -Edge dimmers.
- “LE” (Leading Edge Mode) suitable for the operation of loads that are to be dimmed with Leading -Edge dimmers
IMPORTANT NOTE !
When used with wound transformers (magnetic), only the mode “LE”
(leading edge) can be used !
“TEauto” will NOT work in this case! In addition, the basic brightness
must be set directly during installation ! Non-ob-servance can lead to the
defect of the dimmer!
compatible loads
Compatible loads for TE-auto and TE mode
LED dimmable
| Dimmable LED lamps with integrated driver
| Dimmable LED lamps with dimmable electronic transformer
| Standard filament lamps,
High-voltage halogen lamps
| Low-voltage halogen lamps with electronic driver/transformer
Compatible loads for LE mode
Must be set manually via button (B)
| Low-voltage halogen lamps with standard driver/transformer
Notes on Disposal
The product is designated for separate collection at an appropriate collection point. Do not dispose of the product with household waste. For more information, contact the retailer or the local authority responsible for waste management.
Care
Before cleaning the unit, disconnect it, if necessary form other components; do not use aggressive cleaning agents. The unit has been carefully checked for defects. If nevertheless you do have cause for complaint, please go back to the retailer where you have bought the product together with your proof of purchase. We are not liable for damage arising from incorrect handling, improper use or wear or tear. We reserve the right to make technical modifications.
Safety
General Safety
-
Read the manual carefully before use. Keep this manual for future reference.
-
Only use the product for its intended purposes. Do not use the product for other purposes than described in the manual.
-
Do not use this product if any part is damaged or defective. If the product is damaged or defective, replace the product immediately.
-
This product shall not be used by children without the supervision of an adult. Children shall not play with the device.
-
Do not modify the product in any way.
• Do not expose the product to water or moisture. (IP 20)
• Do not immerge the product into water. (IP 44 - IP 67) -
Keep the product away from heat sources.
-
Do not block the ventilation openings.
-
Do not look directly into the LED lamp.
-
Keep a minimum distance of 1 meter between the lamp and the surface being illuminated.
Electrical safety
- To reduce risk of electric shock, this product should only be opened by an authorized technician when service is required.
- Do not use the product if the cable or plug is damaged or defective. When damaged or defective, it must be replaced by the manufacturer or an authorised repair agent.
- Before use, always make sure that the voltage is the same as the voltage on the rating plate of the device.
- Make sure that the cable does not hang over the edge of a worktop and cannot be caught accidentally or tripped over
Warning
- The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person.
- Caution, risk of electric shock.
- The external flexible cable or cord of this luminaire cannot be replaced; if the cord is damaged, the luminaire has to be destroyed.
Disclaimer
Designs and specifications are subject to change without notice. All logos, brands and product names are trademarks or registered trademarks or their respective holders and are hereby recognized as such.
Please visit us online on our website: www.temo-elektro.de for more information about our company and our products.
ocumentation
The product has been manufactured and supplied in compliance with all relevant regulations and directives, valid for all member states of the European Union. The product complies with all applicable specifications and regulations in the country of sales.
CE declaration
This product complies with the following directives:
LVD: 2014/35/EU
EMC: 2014/30/EU
RoHS: 2011/65/EU
Notes
MV#: 20201209 22:09
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>