BRESSER 7009974 Thermo/Hygro Sensor Instruction Manual

June 5, 2024
BRESSER

BRESSER LOGO Thermo/Hygro Sensor
Art.No.: 7009974 INSTRUCTION MANUAL

ABOUT THIS INSTRUCTION MANUAL
These operating instructions are to be considered a component of the device. Please read the safety instructions and the operating instructions carefully before use. Keep these instructions for renewed use at a later date. When the device is sold or given to someone else, the instruction manual must be provided to the new owner/user of the product.

GENERAL WARNINGS

  • Risk of electric shock — This device contains electronic components that operate via a power source (batteries). Children should only use the device under adult supervision. Only use the device as described in the manual; otherwise, you run the risk of an electric shock.

  • Choking hazard — Children should only use the device under adult supervision. Keep packaging material, like plastic bags and rubber bands, out of the reach of children, as these materials pose a choking hazard.

  • Risk of chemical burn — Keep batteries out of the reach of children! Make sure you insert the batteries correctly. Leaking battery acid can lead to chemical burns. Avoid contact of battery acid with skin, eyes and mucous membranes. In the event of contact, rinse the affected region immediately with a plenty of water and seek medical attention.

  • Risk of fire/explosion — Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them
    into a fire. Excessive heat or improper handling could trigger a short- circuit, a fire, or an explosion.

  • Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary.

  • Use only the recommended batteries. Always replace weak or empty batteries with a new, complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. The batteries should be removed from the unit if it has not been used for a long time.

SCOPE OF DELIVERY

Sensor, Operating instructions.

BEFORE YOU BEGIN

  • We recommend using alkaline batteries. If temperatures regularly fall below 0°C (32°F), we recommend using lithium batteries.
  • Avoid using rechargeable batteries. (Rechargeable batteries cannot maintain correct power requirements.)
  • Insert batteries before first use, matching the polarity in the battery compartment. 2x AA Batteries are required.

EC DECLARATION OF CONFORMITY
Hereby, Bresser GmbH declares that the equipment type with part number: 7009974 is in compliance with Directive: 2014/53/ EU. The full text of the EU declaration of conformity is available at the following internet address: www.bresser.de/download/7009974/CE/7009974_CE.pdf

UKCA Declaration of Conformity
Bresser UK Ltd. has issued a „Declaration of Conformity“ in accordance with applicable guidelines and corresponding standards. The full text of the UKCA declaration of conformity is available at the following internet address: www.bresser.de/download/7709974/UKCA/7009974_UKCA.pdf

Bresser UK Ltd. • Suite 3G, Eden House, Enterprise Way, Edenbridge, Kent TN8 6Hf, Great Britain

NOTES ON CLEANING

  • Remove the batteries before cleaning.
  • Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do not use any cleaning fluid.
  • Protect the device from dust and moisture.

WARRANTY & SERVICE

The regular guarantee period is 5 years and begins on the day of purchase. You can consult the full guarantee terms and details of our services at www.bresser.de/warranty_terms. Alternatively you can also send an email to manuals@bresser. de or leave a message on +49 (0) 28 72 – 80 74220*. Please always state your name, precise address, a valid phone number and email address, as well as the article number and name.

*Number charged at local rates in Germany (the amount you will be charged per phone call will depend on the tariff of your phone provider); calls from abroad will involve higher costs.

BRESSER 7009974 Thermo Hygro Sensor - FIG 1http://www.bresser.de/warranty_terms

OVERVIEW

BRESSER 7009974 Thermo Hygro Sensor - FIG 2BRESSER 7009974 Thermo Hygro Sensor - FIG
3

  1. Transmission status LED
  2. Wall mounting holder
  3. [ CHANNEL ] , slide switch to assign the sensor to channel 1, 2, 3, 4, 5, 6 or 7
  4. [ RESET ] key
  5. Battery compartment

WIRELESS THERMO-HYGRO SENSOR

  1. Remove the battery door.
  2. Slide the [ CHANNEL ] slide switch to choose a channel.
  3. Insert 2 x AA size batteries into the battery compartment according to the polarity mark on the battery compartment..
  4. Close the battery door.

Note:

  • Ensure to assign different channels of different sensors, in case you need to pair more than one sensors.
  • Once the channel is assigned to a Wireless Thermo-Hygro sensor, you can only change it by removing the batteries or resetting the unit.
  • Avoid placing the sensor in direct sunlight, rain or snow.

PAIRING THE WIRELESS SENSORS WITH THECONSOLE
The console will automatically search and connect to your wireless sensor(s). Once your sensor(s) pair up successful, the sensor(s) signal strength indication and weather information will appear on your console display.

RESET THE SENSOR

In case of mal-function, press [ RESET ] button to reset the sensor.

HOW TO PLACE THE SENSOR

  • Choose a location on the exterior of the home where can shield the sensor from direct sunlight or wet conditions for an accurate reading.
  • Hang it with the wall mount hole or place it directly on flat surface, and make sure the transmission is within 150 meters approx.
  • Minimize obstructions such as doors, walls, furniture, etc.

IMPORTANT NOTE

  • Read and keep these instructions.
  • Do not cover the ventilation holes with any items such as newspapers, curtains etc.
  • Do not clean the unit with abrasive or corrosive materials.
  • Technical specifications and user manual contents for this product are subject to change without notice.

SPECIFICATIONS

Dimensions (W x H x D) 61 x 113 x 39.5mm (2.4 x 4.4 x 1.6 in)
Weight 144g (with batteries)
Main power 2 x AA size 1.5V batteries (Lithium battery recom­mended for low

tempera­ture environment)
Weather data| Temperature and humidity
RF frequency| 868Mhz (EU, UK)
RF transmission range| 150m (300feet) straight distance
Number of channels| 7 (CH1 — 7)
Transmission interval| 60 seconds
Operating temperature range| -40 — 60°C (-40 — 140°F)
Operating humidity range| RH 1°k to 99 %

DISPOSAL

| Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal.
---|---
| Do not dispose of electronic devices in the household garbage! As per the Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.
| In accordance with the regulations concerning batteries and rechargeable batteries, disposing of them in the normal household waste is explicitly forbidden. Please make sure to dispose of your used batteries as required by law — at a local collection point or in the retail market. Disposal in domestic waste violates the Battery Directive. Batteries that contain toxins are marked with a sign and a chemical symbol.
| ¹ battery contains cadmium ² battery contains mercury ³ battery contains lead
| MANUAL DOWNLOAD:
BRESSER 7009974 Thermo Hygro Sensor - FIG 7
http://www.bresser.de/download/7009974

---|---
| SERVICE ANDWARRANTY:
BRESSER 7009974 Thermo Hygro Sensor - FIG 9
http://www.bresser.de/warranty_terms

Errors and technical changes reserved.

BRESSER LOGO Bresser UK Ltd.
Suite 3G, Eden House, Enterprise Way,
Edenbridge, Kent TN8 6Hf, Great Britain

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals