BRESSER 7000024000000 ClimaTemp Hygro DLX Weather Station Instruction Manual
- October 27, 2023
- BRESSER
Table of Contents
- 7000024000000 ClimaTemp Hygro DLX Weather Station
- Imprint (German)
- Validity note
- About this Instruction Manual
- Parts overview and scope of delivery
- Screen display
- Before starting operation
- Setting up power supply
- Manual time setting
- Time zone setting
- Alarm setting
- Clima indicator
- Trend arrow indicators
- Display brightness regulation
- Technical data
- EC Declaration of Conformity
- Disposal
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Weather Station
ClimaTemp Hygro DLX
Instruction manual
7000024000000 ClimaTemp Hygro DLX Weather Station
Visit our website via the following QR Code or web link to find further information on this product or the available translations of these instructions.
http://www.bresser.de/P7000024000000
WARRANTY
http://www.bresser.de/warranty_terms
Imprint (German)
Bresser GmbH Gutenbergstr. 2 46414 Rhede Germany http://www.bresser.de For
any warranty claims or service enquiries, please refer to the information on
“Warranty” and “Service” in this documentation. We apologize for any
inconvenience caused by the fact that we cannot process enquiries or
submissions sent directly to the manufacturer’s address. Errors and technical
changes excepted.
© 2019 Bresser GmbH All rights reserved.
The reproduction of this documentation – even in extracts – in any form (e.g.
photocopy, print, etc.) as well as the use and distribution by means of
electronic systems (e.g. image file, website, etc.) without the prior written
permission of the manufacturer is prohibited. The designations and brand names
of the respective companies used in this documentation are generally protected
by trade, trademark and/or patent law in Germany, the European Union and/or
other countries.
Validity note
This documentation is valid for the products with the following article
numbers:
7000024000000
Manual version: v0420
Manual designation:
Manual_7000024000000_ClimaTemp-Hygro-DLX_en-de_BRESSER_v042020a
Always provide information when requesting service.
About this Instruction Manual
NOTICE
These operating instructions are to be considered a component of the device.
Read the safety instructions and the operating manual carefully before using
this device.
Keep this manual in a safe place for future reference. When the device is sold
or given to someone else, the instruction manual must be provided to the new
owner/user of the product.
Parts overview and scope of delivery
1 SNOOZE/LIGHT touch sensor (snooze function and temporary backlight)
2 Light sensor for backlight (brightness is dimmed in the dark)
3 Display (base unit)
4 Temperature and humidity
5 Display range for channel 1 (blue) Outdoor temperature and humidity
6 Display range for channel 2 (yellow) Outdoor temperature and humidity
7 Display range for channel 3 (orange) Outdoor temperature and humidity
8 Wall bracket (base unit)
9 MODE button
10 ALARM button (alarm setting)| 11 SNOOZE/LIGHT button (snooze function and
temporary backlight)
12 UP button (change selected channel (arrow indicator) and change value
upwards)
13 DOWN button (select temperature unit °C/°F and change value downwards)
14 MAX / MIN button
15 Battery compartment (base unit)
16 DC connection socket for barrel power connector
17 Stand, fold-out
18 Display (wireless sensor)
19 Wall bracket (wireless sensor)
20 °C/°F slide switch (select temperature unit)
21 Channel selector switch Battery compartment (wireless sensor)
---|---
Delivery content:
base unit (A), 3 pcs. wireless sensors (B)
Required batteries (not included):
Station: 3 pcs. Mignon batteries (1.5V, type AAA/LR03)
Sensor: 6 pcs. Mignon batteries (1.5V, type AAA/LR03)
Screen display
1 Standard: current time; Alarm: alarm time
2 Symbol for the radio signal
3 Symbol for enabled alarm
4 Weekday
5 Day and month
6 Trend arrow
7 Temperature and humidity
8 Display range for channel 1 (blue) Outdoor temperature and humidity
9 Display range for channel 2 (yellow) Outdoor temperature and humidity
10 Display range for channel 3 (orange) Outdoor temperature and humidity| 17
Selected channel of the wireless sensor
18 Outdoor temperature (wireless sensor)
19 Outdoor humidity (wireless sensor)
11 Display range arrow indicator
12 Low battery indicator
13 Symbol for highest (MAX) or lowest (MIN) value
14 Climate indicator (optimum, dry, humid)
15 Alarm icon for high (HI AL) or low (LO AL) temperature or humidity
16 Alarm symbol for temperature or humidity
---|---
Before starting operation
NOTICE
Avoid connectivity disruptions!
To avoid connectivity disruptions between the devices, consider the following
points before starting operation.
- Place base station (receiver) and remote sensor (sender) together as close as possible.
- Set up power supply for the base station and wait until the indoor temperature is displayed.
- Set up power supply for the remote sensor.
- Position the base station and the remote sensor within the effective transmission range.
- Ensure that the base station and remote sensor are assigned to the same channel.
When changing batteries always change batteries in the main unit as well as
all remote units and replace them in the correct order, so the remote
connection can be re-established.
If either of the devices is mains-powered, the power supply must be
disconnected for a short moment also for this device when exchanging the
batteries.
If batteries are exchanged in only one of the devices (i.e. the remote
sensor) the signal can’t be received or can’t be received correctly.
Note, that the effective range is vastly affected by buildingmaterials and
position of the main and remote units.
Due to external influences (various RC devices and other sources of
interference), the maximum distance can be greatly reduced.
In such cases we suggest to position the main unit and the remote sensor at
other places.
Sometimes all it takes is a relocation ofone of these components of a few
inches!
Setting up power supply
Base station
-
Remove the battery compartment cover.
-
Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
-
Replace the battery compartment cover.
-
Wait until the indoor temperature is displayed on the base station.
NOTICE! Alternatively, operation with mains power supply (DC 5V) is possible. Proceed as follows: -
Insert the DC connector into the connection socket of the base station.
-
Insert the mains plug into the power outlet.
-
The device is energized directly.
-
Wait until the indoor temperature is displayed on the base station.
NOTICE! When switching from mains power supply to battery power supply or vice versa, the power supply is being disabled for a short moment for technical reasons. In this process all settings made previously, will be deleted.
Remote sensor -
Loosen the screws at the battery compartment cover with a small Philips screwdriver and remove the cover.
-
Insert the batteries into the battery compartment. Ensure that the battery polarity (+/-) is correct.
-
Set the channel selector switch to the desired channel.
NOTICE! This weather station can be operated with up to 3 remote sensors. Each remote sensor being connected must be operated on a different channel. If only one remote sensor is connected, it should be operated on channel 1. -
Replace the cover and retighten it with the screw.
Manual time setting
- Press and hold MODE button for approx. 3 seconds to change to time setting mode.
- Digits to be set are flashing.
- Press UP or DOWN button to change the value.
- Press MODE button to confirm and continue to the next setting.
- Settings order: Year > Month > Day > Weekday Language > 12/24-hours mode > Time zone offset > > Hours > Minutes
- Finally press the MODE button to save the settings and exit the setting mode.
Time zone setting
To set a different time zone, proceed as follows:
- Press and hold MODE button for approx. 3 seconds to change to time setting mode.
- Press the MODE button multiple times until the display shows the time offset 00 Hr.
- Press UP or DOWN button to select the desired time deviation in hours (-23 up to +23 hours).
- Finally press the MODE button to save the settings and exit the setting mode.
Alarm setting
- Press the MODE button to switch to the settings mode for the alarm time. “AL” is displayed instead of the seconds.
- Press the UP button to enable or disable the alarm. When the alarm is enabled, the symbol appears on the display.
- Press the MODE button for about 3 seconds to enter the settings mode for the alarm time. The first value to be set flashes.
- Press UP or DOWN button to change the value.
- Press the MODE button to confirm and switch to the next setting.
- Settings sequence: Hours > Minutes > Snooze Interval (01-20 minutes)
- Finally, press the MODE button to save the settings and exit settings mode.
- When the alarm sounds, press any button to stop the alarm.
Snooze function
- When the alarm sounds press the SNOOZE/LIGHT touch sensor at the top of the device or the SNOOZE/LIGHT button on the back to activate the snooze function. The alarm will sound again in 5 minutes.
- Press any other button when the alarm sounds to interrupt the alarm until the alarm time will be reached again.
- The alarm will be turned off automatically if no button is pressed within 2 minutes.
- The default interval of 5 minutes for the snooze function can be changed in the alarm setting mode.
Receiving measurements automatically
Once the power supply is enabled, the base station will display the
measurement readings for indoors.
First readings from the outdoor sensor will be displayed within 3 minutes
after powering it on.
If no signal is received, proceed as follows:
Press the UP button for about 2 seconds to initate reception of measurements
again.
Manual measurement display
- Press MAX/MIN button several times to display the stored values one after another.
- Display order: Current values > MAX (highest values) > MIN (lowest values)
- When displaying highest or lowest values, press and hold MAX/MIN button for approx. 3 seconds to delete all saved values.
HI/LO Alert
HI/LO alert are used to alert you of certain weather conditions. Once
activated, an alarm sound is triggered and the alert icon flashes as soon as a
set value is reached. Supported areas and alarm types:
Area | Type of alert available |
---|---|
Indoor temperature | HI AL / LO AL |
Indoor humidity | HI AL / LO AL |
Outdoor temperature | HI AL / LO AL |
Outdoor humidity | HI AL / LO AL |
HI AL = High alert / LO AL = Low alert
HI/LO alert setting
-
First, select an area (channel 1, 2, 3 or Indoor). Press the UP button repeatedly until the arrow indicator is at the desired position.
-
Press and hold ALARM button for approx. 3 seconds to enter the setting mode.
-
Press UP or DOWN button to change the value.
-
Press ALARM button to confirm and continue to the next setting.
-
Settings order: Temperature HI AL > Temperature LO AL > Humidity HI AL > Humidity LO AL Enable/Disable HI/LO Alert
-
First, select an area (channel 1, 2, 3 or Indoor). Press the UP button repeatedly until the arrow indicator is at the desired position.
-
Press and hold ALARM button for approx. 3 seconds to enter the setting mode.
-
Press and hold ALARM button again for approx. 3 seconds to activate the temperature alarm.
-
Press ALARM button to confirm and continue to the next setting.
Note: -
When ALERT alarm is on, the area and type of alarm that triggered the alarm will be flashing and the alarm will sound for 2 minutes.
-
Press SNOOZE/LIGHT button when alarm sounds to interrupt the alarm. The alarm will then start again after 2 minutes.
Clima indicator
- COMFORT: Optimal (Temperature between 20-28°C and humidity between 40% and 70%)
- DRY: Humidity >65%
- WET: Humidity <45%
The clima indicator is a pictorial indication based on air temperature and humidity in an attempt to determine comfort level.
Note:
- Comfort indication can vary under the same temperature, depending on the humidity.
- There is no comfort indication when temperature is below 0° C (32° F) or over 60° C (140° F)
Trend arrow indicators
- Rising
- Steady
- Falling
The temperature and humidity trend indicator shows the trends of changes in the forthcoming few minutes. Arrows indicate a rising, steady or falling trend.
Display brightness regulation
- In normal display mode, press SNOOZE/LIGHT button, to activate the full display brightness for 10 seconds.
- In mains adapter operation (DC 5V) the backlight remains always activated. The light sensor ensures that the brightness is automatically reduced in a dark environment.
- NOTICE! In battery mode the display brightness regulation is disabled.
Technical data
Base station
Batteries: 3x AAA, 1.5 V
Power supply (optional): DC 5V 500 mA mains plug
Temperature measuring unit: °C / °F
Temperature measuring range: -9,9°C – 60°C (-14°F – 140°F)
Humidity measuring range: RH 20% – 95%
Time format: 12 or 24 hours
Dimensions: 117 x 136 x 25 mm (B x H x T)
Weight: 244 g
Remote sensor
Batteries: 2x AAA, 1.5 V
Radio controlled signal: DCF
Transmission frequency: 433 MHz
Maximum radio frequency power: under 10mW
Temperature measuring unit: °C / °F
Temperature measuring range: -50°C – 60°C (-58°F – 140°F)
Humidity measuring range: RH 20% – 95%
EC Declaration of Conformity
Hereby, Bresser GmbH declares that the equipment type with item number 7000024000000 : is in compliance with Directive: 2014/30/EU. The full text of the EU declaration of conformity is available at the following internet address: www.bresser.de/download/7000024000000/CE/7000024000000_CE.pdf
Disposal
Dispose of the packaging materials properly, according to their type, such as
paper or cardboard. Contact your local waste-disposal service or environmental
authority for information on the proper disposal.
Do not dispose of electronic devices in the household garbage!
As per Directive 2012/19/EC of the European Parliament on waste electrical and
electronic equipment and its adaptation into German law, used electronic
devices must be collected separately and recycled in an environmentally
friendly manner.
Do not dispose of batteries and rechargeable batteries with the household
waste. You are legally required to return used batteries and rechargeable
batteries. After they are used, the batteries can be returned free of charge
to our point of sale or to a nearby location (for example, retailers or
municipal collecting points).
Batteries and rechargeable batteries are marked with a symbol of a crossed-out
dustbin and the chemical symbol of the pollutant. “Cd” stands for Cadmium,
“Hg” stands for mercury and “Pb” stands for lead.
Warranty
The regular guarantee period is 2 years and begins on the day of purchase. To benefit from an extended voluntary guarantee period as stated on the gift box, registration on our website is required.
You can consult the full guarantee terms as well as information on extending the guarantee period and details of our services at www.bresser.de/warranty_terms.
Service
Please contact the service centre first for any questions regarding the
product or claims, preferably by e-mail.
e-mail: service@bresseruk.com
Telephone*: +44 1342 837 098
BRESSER UK Ltd
Suite G3, Eden House
Enterprise Way
Edenbridge, Kent TN8 6HF
United Kingdom
- Number charged at local rates in the UK (the amount you will be charged per phone call will depend on the tariff of your phone provider); calls from abroad will involve higher costs.
References
- Bresser | Startseite | Expand Your Horizon mit BRESSER
- bresser.de/garantiebedingungen
- Bresser | BRESSER ClimaTrend Hygro Quadro Colour Thermo-/ Hygrometer mit 3 Sensoren | Expand Your Horizon
- bresser.de/warranty_terms
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>