BRAYER BR4930 Air Purifier Instruction Manual
- June 3, 2024
- BRAYER
Table of Contents
BR4930 Air Purifier
Instruction Manualhttp://tm.by
AIR PURIFIER BR4930
DESCRIPTION
-
Filter lid
-
Filter
-
Air inlet grid
-
Control panel
-
Body
-
Fragrance basket
-
Air outlet grid
Control panel (4) -
On/off/operation mode selection button « »
-
Low-speed indicator
-
Medium speed indicator
-
Maximal speed indicator « »
-
Ionization on/off button « »
-
Filter use the reset button « »
AIR PURIFIER FEATURES
Filters and air ionizers are used to clean the indoor air.
Prefilter:
The filtering mesh retains dust particles that are >0.2 mm, the filter is easy
to clean and it can be used multiple times.
НЕРА filter and coal filter:
- The HEPA filter cleans the air from dust particles with a diameter of fewer than 2.5 microns and holds plant pollen, dangerous viruses, and bacteria.
- Activated carbon absorbs unpleasant odors and tobacco smoke holds allergens and keeps pollen from plants and animal hair. Air ionizer:
- The ionizer saturates the air with negatively charged ions, which are necessary for the normal life of people, animals, and plants. In the ionization mode, you feel clean, almost mountain air.
ATTENTION! The air purifier does not retain such gases as carbonic oxide (CO) or radon (Rn) and it cannot be used for air purifying in case of fire or dangerous chemical release.
SAFETY MEASURES AND OPERATION RECOMMENDATIONS
Read the operation instructions carefully before using the air purifier, after
reading keep them for future reference.
-
Use the unit for its intended purpose only, as it is stated in this manual.
-
Mishandling the unit can lead to its breakage and cause harm to the user or damage to the user’s property, which is not covered by warranty.
-
Make sure that the operating voltage of the unit indicated on the label corresponds to your home mains voltage.
-
Place and use the air purifier on a flat dry and steady surface. The distance between the unit body and other furniture and interior objects should be at least 20 cm and 30- 50 cm above the unit.
-
Do not use the air purifier outdoors.
-
It is recommended not to use the unit during lightning storms.
-
Protect the unit from impacts, falling, vibrations, and other mechanical stress.
-
Never leave the unit connected to the mains unattended.
-
Do not use the unit near heating appliances, heat sources, or open flames.
-
Do not use the unit in places where aerosols are used or sprayed, and in proximity to inflammable liquids.
-
Do not immerse the air purifier, the power cord, or the power plug in water or any other liquids.
Do not use the unit in proximity to the kitchen sink, in bathrooms, swimming pools, or other containers filled with water. -
If the unit is dropped into water, unplug it immediately, and only then you can take the unit out of the water.
-
Do not let the power cord touch hot surfaces and sharp edges of furniture.
-
Unplug the unit after usage or before cleaning. When unplugging the unit, hold the power plug and carefully remove it from the mains socket, do not pull the power cord, as this can lead to its damage and cause a short circuit.
-
Do not touch the unit body, the power cord, and the power plug with wet hands.
-
Use only the removable parts supplied with the unit.
-
Do not cover the air purifier during the operation.
-
Do not cover the air inlets on the unit body and avoid getting foreign objects inside them.
-
Clean the unit regularly.
-
For a child, for safety reasons do not leave polyethylene bags used as packaging unattended.
Attention! Do not allow children to play with polyethylene bags or packaging film. The danger of suffocation! -
The unit is not intended for use by children.
-
Do not leave children unattended to prevent using the unit as a toy.
-
Do not allow children to touch the operating surface, the unit body, the power cord or the power plug during the operation of the unit.
-
Be especially careful if children or disabled persons are near the operating unit.
-
During the unit operation and breaks between operation cycles, place the unit out of reach of children.
-
The unit is not intended for usage by physically, sensory, psychically, or mentally disabled persons (including children) or by persons lacking experience or knowledge if they are not under the supervision of a person who is responsible for their safety or if they are not instructed by this person on the usage of the unit.
-
From time to time check the power cord integrity.
-
If the power cord is damaged, it should be replaced by the manufacturer, maintenance service, or similarly qualified personnel to avoid danger.
-
Do not repair the unit by yourself. Do not disassemble the unit by yourself, if any malfunction is detected, and after the unit was dropped, unplug it and apply it to the service center.
-
To avoid damages, transport the unit in the original package.
-
Keep the unit in a dry cool place out of reach of children and disabled persons.
THE UNIT IS INTENDED FOR HOUSEHOLD USE ONLY, DO NOT USE THE UNIT FOR
COMMERCIAL OR LABORATORY PURPOSES.
BEFORE THE FIRST USE
After unit transportation or storage at negative temperature, unpack it and
wait for 3 hours before using.
-
Unpack the unit and remove all the packaging materials.
-
Keep the original package.
-
Read the safety measures and operating recommendations.
-
Check the delivery set.
-
Examine the unit for damages, in case of damage do not plug it into the mains.
-
Make sure that the specified specifications of the power supply voltage of the unit correspond to the specifications of your mains. When using the unit in the mains with 60 Hz frequency, the unit does not need any additional settings.
Preparing the filters before using the air purifier
ATTENTION! Before removing the lid (1), make sure that the power plug is not inserted into the main socket. -
Place the air purifier in a horizontal position.
-
Remove the lid (1) by turning it to the position « » (pic. 1).
-
Remove the filter (2) from the air purifier body (5) (pic. 2).
-
Unpack the filters (pic. 3).
-
Install filter (2) into the air purifier body (5) (pic. 4).
-
Install the lid (1) back to its place and turn it to the position « » (pic. 5).
-
The air purifier is ready for operation.
USING THE AIR PURIFIER
- Place and use the air purifier on a flat dry and steady surface. The distance between the unit body and other furniture and interior objects should be at least 20 cm and 30- 50 cm above the unit.
Switching on
- The control panel (4) buttons are sensory, you just have to touch the button. Every touch of the button is accompanied by a sound signal.
- Connect the power plug to the mains socket, and you will hear a sound signal, and the air purifier will switch on in standby mode.
- To switch the air purifier on, touch the on/off/operation mode selection button (8) « » on the control panel (4), the air purifier will switch on at low speed, and the indicator (9) will light up.
- To switch the air purifier off, touch the on/off/operation mode selection button (8) « » for 3-5 seconds, the air purifier will switch to the standby mode. Then unplug the unit.
- To change the speed operation mode, touch the on/off/operation mode selection button (8) « », the speed operation modes are confirmed with the indicators (9, 10, 11).
- Maximal operation speed is displayed with the indicator (11) « ».
Ionization mode
- To switch the ionization mode on, touch the button (12) « ».
- To switch the ionization mode off, touch the button (12) « » again.
Fragrance basket
-
Remove the aromatic oil container (pic. 6), add some drops of aromatic oil and install the container back to its place.
• Resetting the filter operation time
• If during the air purifier operation the indicator (13) « » lights up and starts flashing, it is necessary to clean or replace the filter (2).
ATTENTION! Before removing the lid (1), make sure that the power plug is not inserted into the main socket. -
Remove the lid (1) by turning it to the position « » (pic. 1).
-
Remove the filter (2) from the air purifier body (5) (pic. 2).
-
Using a vacuum cleaner with a corresponding attachment clean the outer surface of the filter (2).
-
Install filter (2) into the air purifier body (5) (pic. 3).
-
Install the lid (1) back to its place and turn it to the position « » (pic. 5).
-
Switch the air purifier on by touching the on/off/operation mode selection button (8) « ».
-
Touch the button (13) « » and hold it for 3-5 seconds, you will hear a sound signal, and the indicator « » will go out.
CLEANING AND MAINTENANCE
- Before cleaning the air purifier switch it off and make sure that the power plug is not inserted into the mains socket.
- Wipe the unit body (5) with a slightly damp cloth and then wipe dry.
- Do not use liquid detergents, abrasive cleaners, and any solvents to clean the air purifier.
- To avoid the risk of electric shock provides that no water or other liquid gets into the air purifier’s body.
- To clean the air grids (3, 7), use a vacuum cleaner with a corresponding attachment.
- To extend the service life of the filters (2), it is recommended to periodically remove the filters (2), and clean them from dust, lint, etc.
STORAGE
- After cleaning put the air purifier away for storage in a dry cool place away from children and disabled persons.
- Before using the air purifier next time, it is recommended to check the unit operability and the integrity of the power cord isolation and the power cord plug.
DELIVERY SET
- Air purifier with installed filters – 1 pc.
- Instruction manual – 1 pc.
TECHNICAL SPECIFICATIONS
- Power supply: 220-240 V ~ 50 Hz
- Rated input power: 25 W
- Negative ion output: ≥ 10,0 mln/cm³ (in 10 cm from the air outlet grid)
- Room area: to 18 m²
- Productivity: 150 m³/hour
RECYCLING
To prevent possible damage to the environment or harm to the health of people
by uncontrolled waste disposal, after the expiration of the service life of
the unit or the batteries (if included), do not discard them with usual
household waste, take the unit and the batteries to specialized stations for
further recycling.
The waste generated during the disposal of products is subject to mandatory
collection and consequent disposal in the prescribed manner.
For further information about recycling this product apply to a local
municipal administration, a household waste disposal service, or to the shop
where you purchased this product.
The manufacturer reserves the right to change the design, structure, and
specifications not affecting the general operating principles of the unit,
without prior notice.
The unit operating life is 3 years
The manufacturing date is specified in the serial number.
In case of any malfunctions, it is necessary to apply promptly to the
authorized service center.
Hergestellt für «Ruste GmbH»,
Berggasse 18/18, 1090 Wien,
Osterreich
т.: +7 (495) 297-50-20,
e-mail: info@brayer.su
Made in China
References
Read User Manual Online (PDF format)