DEPSTECH DS350 Industrial Endoscope User Manual

June 3, 2024
DEPSTECH

DEPSTECH - LOGO

DS350 Industrial Endoscope
User Manual

DS350 Industrial Endoscope

DEPSTECH DS350 Industrial Endoscope

Product Manual
DEPSTECH® DS350 industrial endoscope was featured as a cost-efficient industrial endoscope with a 4.3” digital screen, which was invented to help with car maintenance or pipeline repair. We hope that you can use this efficient tool to enable you to finish the job more rapidly and help you discover the delights of miniature worlds.
Battery
Please do not try to change the built-in battery yourself, it may raise the risks of leading the battery to overheat or getting people harmed. For better battery life spans, we would recommend you charge the device every 3~6 months. (No matter uses it or not)
Operation and storage conditions
Please keep the tools out of the fire source, especially keep it away from temperatures higher than 158℉(70℃) – or lower than -50℉(-10℃). Be cautious the required working temperature should between 32~113℉(0~45℃ ). Please keep it in a dry, clean area, free from oil, water, or chemical liquid. Those measures will help the device maintain longer life pans, and also it will greatly help to keep dangerous situations far away.
※ The Child can only operate this device with the guidance of adults, please do not let them operate this device alone.

Product introduction

DEPSTECH DS350 Industrial Endoscope - fig

  1. Power Button
    Hold this button for 2s to power on/off the endoscope.

  2. “OK| ” Button
    Confirm choice/Long press to enter the album or exit the album/Click to play or pause;

  3. “ | ” Button
    a: Time adjustment
    b: In the menu mode, select the next directory
    c: Click to dim the LED lightness
    d: Press 2 seconds to rotate the image 180°

  4. “ | ” Button
    a: Time adjustment
    b: In the menu mode, select the previous directory
    c: Click to brighten the LED lightness
    d: Press 2 seconds to change the lens

  5. “ | ” Button
    Hold this button to start the video record, and a single press to take a photo/end the video record.

  6. Menu Button
    Click to enter the menu for more settings.DEPSTECH DS350 Industrial
Endoscope - fig 1

  7. TF Card Slot
    Support up to 32G TF card. (The TF card has been inserted into the machine, please format it for the first time of usage)

  8. Charging Status LED indicator
    Red LED indicator flash: Charging status
    Red LED indicator stays on: Charging finished

  9. Reset Button
    Short-click the reset button with the reset pin to shut down the device.

  10. Micro-USB Charging Port
    Charge the endoscope via a Micro-USB cable.

Description of Product Functions:

Photo/Video:
Take photos by pressing | a button, a long press to start the video recording, and a single press to end the video recording.
View Photos:
Long press OK | in preview mode to enter the photo album, and press / / / to view photos. Long press OK / **again to exit the photo album.
Delete Photos:
When viewing photos, press to choose to delete the current photo or delete all photos, and press again to return to the album.
Screen Rotation:
Long press the / rotation button, and the image will rotate 180°.
Lens Switching (only applicable to double-lens products):
Long press the / button to switch between the main lens, side lens, and dual lens.
Lens LED Brightness Adjustment:
Click the / key to lower the brightness, and click the key to increase the brightness.
Copy photo and video files to the computer:**
The device does not support a USB data cable to transfer data, you can use a TF card reader to copy data directly.

Introduction to the Menu Interface:

Enter the MENU interface: Press to enter the menu interface, press / / / to select options, and then press OK / ****to enter the options interface. Press again to exit.

  1. Resolution Setting: Enter the resolution interface, press / / / to select the resolution, and then press OK / ****to confirm;
  2. Language Setting: Enter the language setting interface, press / / / to select the language, and then press  OK / ****to confirm;
  3. Auto OFF Setting: Enter the Auto OFF setting interface, press / / / to select the time, and then press  OK / ****to confirm;
  4. TF Card Formatting: Enter the formatting interface, choose whether to format, and then press OK / ****to confirm;
  5. System Reset: Enter the System Reset Interface, choose whether to restore the factory settings and then press OK / ****to confirm;
  6. Time Setting: Enter the time setting interface, press OK / ****to select the year, month, day, minute, and second to be adjusted, press / / /  to adjust the time, and press to exit after setting;
  7. Storage Space: Check the memory card capacity and the remaining memory;
  8. Software Version: Check the firmware version number of this product.

Charging Guide:

  1. Connect the device to the DC 5V adapter for charging;
  2. The red indicator light flashes when the device is charging and is always on when fully charged.

Specifications

Model DS350 FHD DS350 Dual Camera
Screen Spec 4.3″ Super LCD Screen
Camera Diameter 0.216 in 0.31 in
Best Focal Range 1.18-3.15 in 1.18-3.15 in / 0.79-2.36 in
Video Spec 1080 P / 25 FPS
Photo Resolution 2 MP 2 x 2 MP
Battery Life 3 H
Waterproof IP67
Cable Length 16.5 FT

Charging Voltage
and Current| DC 5V/2A

FAQ

Q1: The image quality wasn’t as good as advertised.

A1: Please adjust the length between the camera and the object that you’re observing into the focal range. – The focal range should be 1.18”~3.15” for the single-camera version, and 1.18”~3.15” / 0.79”~2.36” in for dual camera version. Besides, it’s essential to adjust the brightness of your endoscope for the best image quality. It will do a great help if you wipe the lens of the camera regularly after use.

Q2: The endoscope was failing to turn on.

A2: It might be due to low battery status, especially in cold areas. To release the low battery state you’ve to fully charge the endoscope. You can charge the endoscope for 4~5 H and try to turn it on again.

Q3: The endoscope can not take a picture or record a video.

A3: First please make sure that the TF card has been inserted into the machine or not. Then make sure that you’ve formatted the TF card at the first use. You can follow the steps below:
– Short press menu
– Find and choose “Formate”, then choose “OK”.s

Customer Service
Please contact us if you have any questions,
we love to hear from you
www.depstech.com
[email protected]
Facebook Official Page: @DEPSTECH. FANS
Shenzhen Deepsea Innovation Technology Co., Ltd.
Room 1901-1902, Jinqizhigu Building, No.1 Tangling Road, Nanshan District, 518055, Shenzhen, CN
Made in China