DEPSTECH DS300 Dual Lens Endoscope 1080p Digital Video Snake Camera User Manual

June 8, 2024
DEPSTECH

DEPSTECH DS300 Dual Lens Endoscope 1080p Digital Video Snake Camera

DEPSTECH-DS300-Dual-Lens-Endoscope-1080p-Digital-Video-Snake-Camera-
PRO

Product manual
DEPSTECH® DS300 industrial endoscope was featured as a cost efficient industrial endoscope with 4.3” digital screen, which was invented to help car maintenance or pipeline repairing. We hope that you can use this efficient tool to enable you to finish the job more rapidly and help you discover the delights of miniature worlds.

Battery

Please do not try to change the built-in battery yourself, it may raise the risks of leading the battery overheat or get people harmed. For better battery life spans, we would recommend you charge the device every 3~6 months. (No matter uses it or not)

Operation and storage conditions

Please keep the tools out of fire source, especially keep it away from temperature higher than 158℉ (70℃) – or lower than -50℉ (-10℃). Be cautious the required working temperature should between 32~113℉ (0~45℃). Please keep it in dry, clean area, free from oil, water, or chemical liquid. Those measures will help the device maintain longer lifes pans, also it will do great help to keep the dangerous situation far away.

The Child can only operate this device with the guidance of adults, please do not let them operate this device alone.

Product introduction

DEPSTECH-DS300-Dual-Lens-Endoscope-1080p-Digital-Video-Snake-Camera-
\(1\)

  1. Power Button
    Hold this button for 2s to power on/off the endoscope.

  2. Photo Shoot/Video Record Button
    Hold this button to start video record, single press to take a photo/end the video record.

  3. Button
    Click to brighten the LED lights of the camera or move the cursor down.

  4. Button
    Click to dim the LED lights of the camera or move the cursor up.

  5. 180° Image Rotate Button
    Click to rotate the real-time image 180°; Hold this button to switch main/side camera. (For dual cam version only, support dual-cam mode, which can project the real time image of main/side camera at the same screen display)

  6. OK/Play Button
    Click to confirm choices in the menu; Hold this button to enter/exited the album.

  7. Menu Button
    Click to enter the menu for more setttings.DEPSTECH-DS300-Dual-Lens-
Endoscope-1080p-Digital-Video-Snake-Camera- \(4\)

  8. Charging Status LED indicator

  9. TF Card Slot
    Support up to 32G TF card. (The TF card has been inserted into the machine, please format it for the first time of usage)

  10. Micro-USB Charging Port
    Charge the endoscope via Micro-USB cable.

  11. Reset Button
    Short click the reset button with the reset pin to shut down the device.

Description of Product Functions

  • Photo/Video:
    Take photos by pressing button, and long press to start or end video recording.

  • View Photos:
    Long press in preview mode to enter the photo album, and press to view photos. Long press again to exit the photo album.

  • Delete Photos:
    When viewing photos, press to choose to delete the current photo or delete all photos, and press again to return to the album.

  • Screen Rotation:
    Press the rotation button, and the image will rotate 180°.

  • Single and Double-Lens Switching (only applicable to double-lens products):
    Long press the button to switch among main lens, auxiliary lens and dual-lens.

  • Lens LED Brightness Adjustment:
    Click the key to lower the brightness, and click the key to increase the brightness.

  • Copy photo and video files to computer
    The device does not support USB data cable to transfer data, you can use a TF card reader to copy data directly.

Introduction to the Menu Interface:

Enter the MENU interface: Press to enter the menu interface, press to select options, and then press to enter the option interface. Press again to exit.

  1. Resolution Setting: Enter the resolution interface, press to select the resolution, and then press to confirm;
  2. Language Setting: Enter the language setting interface, press to select the language, and then press to confirm;
  3. Auto OFF Setting: Enter the Auto OFF setting interface, press to select the time, and then press to confirm;
  4. TF Card Formatting: Enter the formatting interface, choose whether to format, and then press to confirm;
  5. System Reset: Enter the System Reset Interface, choose whether to restore the factory settings, and then press to confirm;
  6. Time Setting: Enter the time setting interface, press to select the year, month, day, minute and second to be adjusted, press to adjust the time, and press to exit after setting;
  7. Storage Space: Check the memory card capacity and the remaining memory;
  8. Software Version: Check the firmware version number of this product.

Specifications

**Model** **DS300 FHD** **DS300 Dual Camera**
**Screen Spec** **4.3” Super TFT LCD Screen**
**Waterproof** **IP67 Rating for the Probe**
**Camera Diameter** **0.22 in** **0.31 in**
**LED** **6 x LED** **7 x LED**
**Best Focal Range** **1.96~3.93 in** **Main cam:

1.18~3.93 in Side cam: 0.79~2.36 in
****
Video Spec| ****1080 p / 25 fps
****
Photo Resolution| ****2 MP| ****2 x 2 MP
****
Cable Length| ****16.5 ft
Charging Voltage and current| ****DC 5V/2A
****
LED Indicator Status| ****Red LED indicator flash: Charging status Red LED indicator stay on: Charging finished**

FAQ

  • Q1: The image quality wasn’t that good as advertised?
    A1: Please adjust the length between the camera and the object that you’re observing into the focal range. The focal range should be 1.96”~3.93” for single camera version, and 1.18”~3.15”/0.79”~2.36” in for dual camera version. Besides, it’s essential to adjust the brightness of your endoscope for the best image quality. It will do a great help if you wipe the lens of the camera regularly after used.

  • Q2: The endoscope was failing to turn on?
    A2: It might due to low battery status, especially in cold area. To release the low battery state you’ve to fully charge the endoscope. You can charge the endoscope for 4~5 H and try to turn it on again.

  • Q3: The endoscope can not take a picture or record a video?
    A3: First please make sure that the TF card has been inserted into the machine or not. Then make sure that you’ve formatted the TF card at the first use.
    You can follow the steps below:

    1. Short press menu
    2. Find and choose “Format”, then choose “OK”.

FCC

FCC Requirement: changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. this device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

CE compliance: This device complies with EN 60065 standard, which means this device will not do harm to the user or products as following situations: 1)Electric shock 2)High temperature 3)Radiation 4)Explosion from inner 5)Mechanical Harm 6)Fire Hazard 7)Chemical burns.

EU Conformity Statement: This product and – if applicable – the supplied accessories too are marked with “CE” and comply therefore with the applicable harmonized European standards listed under the EMC Directive 2004/108/EC, the RoHS Directive 2011/65/EU and Amendment (EU) 2015/863.

WEEE Notice: 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.info

2013/56/EU (battery directive): This product contains a battery that cannot be disposed of as unsorted municipal waste in the European Union. See the product documentation for specific battery information. The battery is marked with this symbol, which may include lettering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the battery to your supplier or to a designated collection point. For more information see: www.recyclethis.info

Customer Services
Please contact us if you have any questions, we love to hear from you:

www.depstech.com
support@depstech.com
Facebook Official Page: @DEPSTECH.FANS

Shenzhen Deepsea Innovation Technology Co., Ltd.
Room 1901-1902, Jinqizhigu Building, No.1 Tangling Road, Nanshan District, 518055, Shenzhen, CN

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals