Industrial Endoscope DS300

The Industrial Endoscope DS300 is a portable device designed for visual inspections in hard-to-reach areas. It comes with a built-in battery that should not be changed by the user to avoid overheating or harm. To ensure better battery life, it is recommended to charge the device every 3-6 months, regardless of usage.
For optimal operation and storage, keep the tool away from fire sources and extreme temperatures (below -10°C or above 70°C). The required working temperature is between 0°C to 45°C. Additionally, keep the device in a dry, clean area free from oil, water, or chemical liquid to prolong its lifespan and avoid dangerous situations.

Quick Overview of Your New Endoscope!

  1. Power Button: Hold for 2 seconds to power on/off the endoscope.
  2. Photo Shoot/Video Record Button: Hold to start video recording, and single press to take a photo/end the video recording.
  3. Brightness Adjustment Button: Click to brighten the LED lights of the camera or move the cursor down.
  4. Dimming Adjustment Button: Click to dim the LED lights of the camera or move the cursor up.
  5. Single/Double-Lens Switching Button (only applicable to double-lens products): Long press to switch among the main lens, and auxiliary lens.
  6. OK/Play Button: Click to confirm choices in the menu; Hold to enter/exited the album.
  7. Menu Button: Click to enter the menu for more settings.
  8. Charging Status LED indicator
  9. TF Card Slot: Supports up to 32G TF cards. The TF card has been inserted into the machine, please format it for the first time of usage.
  10. Micro-USB Charging Port: Charge the endoscope via a Micro-USB cable.
  11. Reset Button: Short-click with the reset pin to shut down the device.

Battery
Please do not try to change the built-in battery yourself, it may raise the risks of leading the battery to overheat or get people harmed. For better battery life spans, we would recommend you charge the device every 3~6 months. (No matter uses it or not)

Description of Product Functions:

  • Photo/Video: Take photos by pressing the video recording button, and long press to start or end video recording.
  • View Photos: Long press in preview mode to enter the photo album, and press / to view photos. Long press again to exit the photo album.
  • Delete Photos: When viewing photos, press to choose to delete the current photo or delete all photos, and press again to return to the album.
  • Single and Double-Lens Switching (only applicable to double-lens products): Long press the button to switch between the main lens, and the auxiliary lens.
  • Lens LED Brightness Adjustment: Click the key to lower the brightness, and click the increase the brightness.
  • Copy photo and video files to computer: The device does not support a USB data cable to transfer data, you can use a TF card reader to copy data directly.

Operation and storage conditions
Please keep the tools out of fire source, especially keep it away from temperatures higher than 158℉ (70℃) – or lower than -50℉ (-10℃). Be cautious the required working temperature should between 32~113℉ (0~45℃). Please keep it in dry, clean area, free from oil, water, or chemical liquid. Those measures will help the device maintain longer lifes pans, also it will do greatly help to keep the dangerous situation far away.
The Child can only operate this device with the guidance of adults, please do not let them operate this device alone.

Introduction to the Menu Interface:

To enter the MENU interface, press the menu button. Use / to select options, and then press OK/play button to enter the options interface. Press OK/play button again to exit.

  1. Resolution Setting: Enter the resolution interface, press / to select the resolution, and then press OK/play button to confirm.
  2. Language Setting: Enter the language setting interface, press / to select the language, and then press OK/play button to confirm.
  3. Auto OFF Setting: Enter the Auto OFF setting interface, press / to select the time, and then press OK/play button to confirm.
  4. TF Card Formatting: Enter the formatting interface, and choose whether to format or not.
  5. TF Card Formatting: Enter the formatting interface, choose whether to format and then press to confirm; restore the factory settings, and then press to confirm;
  6. Time Setting: Enter the time setting interface, press to select the year, month, day, minute and second to be adjusted, press to adjust the time, and press to exit after setting;
  7. Storage Space: Check the memory card capacity and the remaining memory;
  8. Software Version: Check the firmware version number of this product.

Specifications of DS300


Model

| ****

DS300 FHD

| ****

DS300 Dual Camera

---|---|---


Screen Spec

| ****

4.3” Super TFT LCD Screen


Waterproof

| ****

IP67 Rating for the Probe


Camera Diameter

| ****

0.22 in

| ****

0.31 in


LED

| ****

6 x LED

| ****

7 x LED



Best Focal Range

| ****


1.18~3.15 in

| ****

Main cam: 1.18~3.15 in Side cam: 0.79~2.36 in


Video Spec

| ****

1080 p / 25 fps


Photo Resolution

| ****

2 MP

| ****

2 x 2 MP

Charging Voltage and current| ****

DC 5V/2A

LED

Indicator Status

| ****

Red LED indicator flash:  Charging  status Red LED indicator stay on: Charging finished

FAQ

  1. Q: The image quality wasn’t as good as advertised.
    A1: Please adjust the length between the camera and the object that you’re observing into the focal range. The focal range should be 1.18”~3.15” for single camera version, and 1.18”~3.15”/0.79”~2.36” in for dual camera version. Besides, it’s essential to adjust the brightness of your endoscope for the best image quality. It will do a great help if you wipe the lens of the camera regularly after use.

  2. Q: The endoscope was failing to turn on?
    A2: It might due to low battery status, especially in cold area. To release the low battery state you’ve to fully charge the endoscope. You can charge the endoscope for 4~5 H and try to turn it on again.

  3. Q: The endoscope can not take a picture or record a video.
    A3: First please make sure that the TF card has been inserted into the machine or not. Then make sure that you’ve formatted the TF card at the first use.
    You can follow the steps below:

  4. Short press menu

  5. hort press “ ” button to remove the cursor down

  6. Find and choose “Formate”, then choose “OK”.

Customer Services
Please contact us if you have any questions, we love to hear from you
www.depstech.com
support@depstech.com
Facebook Official Page: @DEPSTECH. FANS

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals