GeoVision GV-RKR1355 RS-485 Wiegand Proximity Reader User Guide

June 3, 2024
GeoVision

GV-RKR1355 RS-485 Wiegand Proximity Reader
User Guide

Package Contents

Kindly ensure the product’s contents upon unpacking; please refer to this quick start guide regarding the product’s specifications and important notices.
the items described below are the standard packaging.

GeoVision GV-RKR1355 RS-485 Wiegand Proximity Reader -
package

Physical Dimension

GeoVision GV-RKR1355 RS-485 Wiegand Proximity Reader -
Dimension

Installation

GeoVision GV-RKR1355 RS-485 Wiegand Proximity Reader -
Installation

Kindly refer to the “ wiring connection” for the NODE ID settings before the hardware installation.
Do not over-tighten the back base screws during installation to prevent distortion.
(A). Mount the back base onto the wall or electrical back box.
(B). Connect the wires in accordance with the wiring instruction below.
(C). Make sure the back base and the reader upper cover guides are aligned.
(D). Install the reader’s upper cover to the back base.
(E). Fasten the screw onto the bottom of the reader.

Wiring Connections

GeoVision GV-RKR1355 RS-485 Wiegand Proximity Reader -
Wiring

Before mounting the reader onto the desired location. Please set the NODE ID (DIP Switch, binary number system).
The position of the components varies according to the reader’s model. Kindly take note of the components during setup.

A Case Sensor
B NODE ID Settings, refer to the chart below.

Node ID Configuration
0 0
1 100000
2 10000
3 110000
4 1000
5 101000
6 11000
7 111000
8 100
9 100100
10 10100
11 110100
12 1100
13 101100
14 11100
15 111100

● Dip(6) is a card format selection.
ON is for reading the document, and OFF is for reading the serial number.
C

Pin Color Wiegand RS-485
1 Red DC+12V IN DC+12V IN
2 Black Ground Ground
3 Yellow RS-485+
4 Blue RS-485-
5 Gray
6 Pink
7 Orange & White Ground
8 Orange
9 Brown Beep Control
10 Purple Case Sensor GND (To Controller GND)
11 White Green  LED Control
12 Green Case Sensor (To Controller Case Sensor)
13 Red & White *W0
14 Gray & White *W1

*Do not use the same set of twisted pairs.
Note:

  1. Kindly use a minimum 22AWG double-shielded aluminum mylar foil twisted pair cable for the connection between the reader and the controller.
  2. In order to reduce long-distance noise, The isolated net of the transmission cable should connect to both ends of the device ground.
  3. The distance between two readers should be over 30cm to prevent radio frequency interference from each other.
  4. Mounting the device around metal could affect the read range. The metal of any type around the device should be avoided while mounting.
  5. The distance between the reader and the controller should not exceed 30 meters.
  6. For optimum read range, kindly use a DC Linear power adaptor for the reader’s power supply.
  7. In order to ensure the reader’s normal operation, the input voltage should be between 12V±10%.
  8. If the reader is installed in an open area or highly humid environment, it is recommended to protect the reader with an external shielding cover.
  9. RS-485 communication Baud rate is 9600.

One-Year Limited Warranty
We warrant this product against defects in material or workmanship for 1 year from the date of purchase. If such a defect is discovered within this warranty limitation, contact your direct vendor for repair or replacement of your unit.
When returning the product, you must ship the product in its original packaging or packaging that gives an equal degree of protection. This warranty becomes invalid if the factory-supplied serial number has been removed or altered on the product.
This warranty does not cover cosmetic damage or damage due to acts of God, accident, misuse, abuse, negligence, or modification of any part of the product. This warranty does not cover damage due to improper operation or maintenance, connection to improper equipment, or attempted repair by anyone other than Us.
In no event shall We liability exceed the price paid for the product from direct, indirect, special, incidental, or consequential, damages resulting from the use of the product, its accompanying software, or it’s documentation. We makes no warranty or representation expressed, implied, or statutory, with respect to its products, contents of use of this documentation and all accompanying software, and specially disclaims its quality, performance, merchantability or fitness for any particular purpose. We reserve the right to revise or update its product, software, or documentation without obligation to notify any individual or entity.

Model ———
Serial no.——–
Date of Purchase——-
Reseller stamp——-
Warranty will be valid only after filling out this form and stamped or signed by the reseller!

Testing

To avoid interference self-detection of the sensitive touch keypad, please do not touch the keypad when inputting power.GeoVision GV-RKR1355 RS-485
Wiegand Proximity Reader - Testing Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and the receiver.
  • Connect the equipment to an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution: To assure continued compliance, any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. (Example – use only shielded interface cables when connecting to computer or peripheral devices)


References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals