silex technology E84 Digital Communication Device User Manual
- June 5, 2024
- silex technology
Table of Contents
silex technology E84 Digital Communication Device
WDCD-3310 is a device that E84 interlock communication by wireless communication during FOUP transfer between the OHT. Overhead Hoist Transfer and semiconductor manufacturing equipment. The WDCD-3310 is equipped on the semicunductor manufacturing equipment.
PARTS AND FUNCTIONS
Parts and Functions|
---|---
POWER LED| Green light on| Power On
Green light flashing| Program changing
Orange light on| Initializing process
Red light on| Hardware error
STATUS LED| Green light on| Power On
Orange light on| Setting various parameters of wireless E84
device via tool
Red light on| Wireless E84 device parameter setting error via tool
W-E84 LED| Green light on| Power On(2.4GHz)
Green light flashing| Communicating in the 2.4 GHz band
Orange light on| Power On(5.8GHz)
Orange light flashing| Communicating in the 5.8 GHz band
Red light on| An error occurred in communication with the wireless E84 unit
3pin connector | Debug port |
---|---|
5pin connector | CPU internal ROM writing only used in the factory |
10pin connector | Connect to semicondutor manufacturing equipment |
12pin connector | Connect to semicondutor manufacturing equipment |
Micro USB | Debug port |
Antenna connector | Connect the antenna |
Push Switch | Used to initialization settings |
Setup
- Use a dedicated cable to connect the 10-pin & 12 pin connector to semiconductor manufacturing equipment.
- Powered by semiconductor manufacturing equipment and controls WDCD-3310.
Basic configration|
---|---
Wireless Frequency Band| ISM(2.4GHz,5.8GHz)
Wireless Channel| Ch3~Ch80(2.4GHz) Ch2~Ch100(5.8GHz)
Wireless Channel Width| 1MHz
Channel Power setting| 20dBm~0dBm(2.4GHz)
20dBm~+2dBm(5.8GHz)
Channel Period| 10,20,30,40,50ms
Receive timeout| 100~60000ms
Commnication timeout| 100~5000ms
Pairing threshold level| 80~-24dB
No threshold
SPECIFICATION
Specification|
---|---
Operating environment| Temperature 0~+40℃
Humidity 20~80%RH (Non condensing)
Strorage environment| Temperature -10~+50℃
Humidity 20~90%RH (Non condensing)
Power supply| DC24V
Wireless I/F| short-range wireless(2.4GHz/5.8GHz)
Push Switch| initializaition swtich ×1
LED
| POWER LED Green/Red/Orange
STATUS LED Green/Red/Orange
W-E84 LED Green/Red/Orange
-
Supplier’s Declaration of Conformity
-
47 CFR 2.1077 Compliance Information
-
Unique Identifier: WDCD-3310
-
Responsible Party U.S. Contact Information
-
Responsible Party Name : silex technology America, Inc.
-
Responsible Party Address : East Sandpointe, #245 Santa Ana, CA 92707
-
Phone: 657-218-5199
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject
to the following two conditions:
- This device may not cause harmful interference, and this device must accept any interference received, including interference undesired.
FCC CAUTION
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment. This
equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Compliance with FCC requirement 15.407
Data transmission is always initiated by software, which is the passed down
through the MAC, through the digital and analog baseband, and finally to the
RF chip. Several special packets are initiated by the MAC. These are the only
ways the digital baseband portion will turn on the RF transmitter, which it
then turns off at the end of the and can radiate radio frequency energy and,
if not installed and used in accordance with the instruction packet.
Therefore, the transmitter will be on only while one of the aforementioned
packets is being transmitted. In other words, this device automatically
discontinue transmission in case of either absence of information to transmit
or operational failure.
Frequency Tolerance: ±60 ppm
This transmitter must not be co-located or operated in conjunction with any
other antenna or transmitter.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment and meets the FCC radio frequency (RF) Exposure
Guidelines as this equipment has very low levels of RF energy.
Read User Manual Online (PDF format)