Lumens MXA310 Table Array Microphone User Manual

June 12, 2024
Lumens

Lumens MXA310 Table Array Microphone User Manual
Lumens MXA310 Table Array Microphone

System Requirements

Operating System Requirements
  • Windows 10
  • Windows 11
System Hardware Requirements
Item Requirements
CPU CPU: Intel i5 / i7 above
Memory Memory: 4GB RAM
Free Disk Space 1GB Free Disk Space
Ethernet Min Screen Resolution: 1920×1080

System Connection and Application

System Connection

System Connection

Scenario

Scenario

Support Devices

Shure
  • Shure MXA310 Table Array Microphone
  • Shure MXA910 Ceiling Array Microphone
  • Shure MXA920 Ceiling Array Microphone
Sennheiser
  • Sennheiser Team Connect Ceiling 2 (TCC2) Ceiling Microphone

When using TCC2 with Cam Connect, please set and configure the channels on the Sennheiser Control Cockpit software first.

Cam Connect is divided into 8 equal parts according to Senheisser’s horizontal angle of view. They correspond to Cam Connect Array Azimuth 1 to 8.
Sennheiser

If the forbidden area is enabled on the Sennheiser Control Cockpit software, the corresponding position of CamConnect will also be affected. Example: If the forbidden area is set to 0° to 60°, the audio signal from 0° to 45° of CamConnect Array Azimuth 1 and 45° to 60° of Array Azimuth 2 will be ignored.
Sennheiser

Nureva
  • HDL300 Audio Conferencing System
Yamaha
  • Yamaha RM-CG Ceiling Array Microphone

Operation Interface Description

Main Screen

Main Screen

No Item Function Descriptions
1 Microphone Device Support Device:

The following brands and models are supportedŸ Shure: MXA910 MXA920 MXA310Ÿ Sennhiser: TCC2Ÿ Nureva: HDL300Ÿ Yamaha: RM-CG1

Device IP: IP location of the microphone device
Port:

  • Shure: 2202

  • Sennheiser: 45

  • Nureva: 8931
    Connect: On/Off
    Advanced

  • Audio Trigger Level > dB: Triggered only if audio source exceeds the preset dB For Sennhiser/ Nureva microphones only

  • Time To Trigger Preset: Capture sound delay setting.When the second point sound triggers, the call preset will be delayed based on the set second.

  • Back To Home Time: Back To Home Time setting.When there is no audio source input on site, reaching the set second will trigger back to Home.

  • Back To Home Position: Home Position setting

Microphone Device

2| Preset setting| After the microphone device is connected, the camera can be controlled to turn to the corresponding position according to the microphone detection position.There will be a green light at the front of the detection position.

  • Tally Light: Receive microphone signal or not (Green for Receive)
  • Array No.: For Shure microphones•    Azimuth Angle: For Sennheiser/ Nureva/ Yamaha microphones Angle can be adjusted manually; Click [Apply] when completed

3| Searching| The connected USB cameras will be displayed

When disconnected, click [Connect] to connect the camera and perform PTZ control.
Microphone Device
When connected, click [Disconnect] to stop the connection.
Microphone Device

4| PTZ Control| Click to enable PTZ controlRefer to 4.2 PTZ Control for function description
5| About| Displaying software version informationFor technical support, please scan the QRcode on the page for assistance

PTZ Contro

PTZ Contro

No Item Function Descriptions
1 Preview window Display the screen currently captured by the camera
2 L/R Direction L/R Direction / Normal
3 Mirror / Flip Set image mirroring/ flip
**4** **** Pan/Tilt/Home Adjust the Pan/Tilt position of the camera

screenClick [Home] key
**5| ** Preset setting| Click the number keys directly to call the preset

  • Save preset: Click [ Set ] first and then a number key
  • Clear preset: Click first and then a number key

6| AF/MF| Switch to Auto Focus/Manual Focus. Focus can be adjusted in Manual.
7| Zoom| Zoom In/ Zoom Out ratio
8| Exit| Exit the PTZ Control page

Troubleshooting

This chapter describes problems you may encounter while using Lumens CamConnect. If you have questions, please refer to related chapters and follow all the suggested solutions. If the problem still occurred, please contact your distributor or the service center.

NO Problems Solutions
1 Unable to search camera devices
  1. Check the power supply of camera or PoE power supply is stable.
  2. Make sure the PC is connected to the camera with the USB cable
  3. Replace the cables and make sure they are not faulty

2| No response from the microphone detection position| Make sure the microphone device is connected (Link)
3| When using with a Sennhesier microphone, no response at the specific angle|

  1. Make sure the Azimuth Angle settings in the Cam Connect software include that angle position
  2. Make sure if the angle is set as the forbidden area on Sennhesier Control Cockpit software. Refer to 3.2 Sennhesier Microphone System for details.

Copyright Information

Copyrights © Lumens Digital Optics Inc. All rights reserved.

Lumens is a trademark that is currently being registered by Lumens Digital Optics Inc.

Copying, reproducing or transmitting this file is not allowed if a license is not provided by Lumens Digital Optics Inc. unless copying this file is for the purpose of backup after purchasing this product.

In order to keep improving the product, the information in this file is subject to change without prior notice.

To fully explain or describe how this product should be used, this manual may refer to names of other products or companies without any intention of infringement.

Disclaimer of warranties: Lumens Digital Optics Inc. is neither responsible for any possible technological, editorial errors or omissions, nor responsible for any incidental or related damages arising from providing this file, using, or operating this product

Lumens Logo

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lumens User Manuals

Related Manuals