BRESSER 8020211B4K000 MyTime iO Wall Clock Instruction Manual

June 5, 2024
BRESSER

BRESSER 8020211B4K000 MyTime iO Wall Clock

ABOUT THIS INSTRUCTION MANUAL
These operating instructions are to be considered a component of the device. Please read the safety instructions and the operating instructions carefully before use. Keep these instructions for renewed use at a later date. When the device is sold or given to someone else, the instruction manual must be provided to the new owner/user of the product. This product is intended only for private use.

GENERAL WARNINGS

CHOKING HAZARD!
Keep packaging material, like plastic bags and rubber bands, out of the reach of children, as these materials pose a choking hazard.

RISK of ELECTRIC SHOCK!
This device contains electronic components that operate via a power source (batteries). Children should only use the device under adult supervision. Only use the device as described in the manual; otherwise, you run the risk of an electric shock.

RISK of FIRE/EXPLOSION!
Do not expose the device to high temperatures. Use only the recommended batteries. Do not short-circuit the device or batteries, or throw them into a fire. Excessive heat or improper handling could trigger a short-circuit, a fire or an explosion!

NOTE!
Do not immerse the unit in water. Do not subject the unit to excessive force, shock, dust, extreme temperature or high humidity, which may result in malfunction, shorter electronic lifespan, damaged batteries and distorted parts. Do not disassemble the device. In the event of a defect, please contact your dealer. The dealer will contact the Service Centre and can send the device in to be repaired, if necessary. Use only the recommended batteries. Always replace weak or empty batteries with a new,complete set of batteries at full capacity. Do not use batteries from different brands or with different capacities. Remove the batteries from the unit if it has not been used for a long time. The manufacturer is not liable for damage related to improperly installed batteries

GENERAL INFORMATION

This item is available in the following variants. The functions and technical data are the same for all models. They only differ in the colour of the dial plate.

  • 8020211 B4K000: green
  • 8020211 CM3000: black
  • 8020211 E8G000: red
  • 8020211 GYE000: white
  • 8020211 MGU000: anthracite
  • 8020211 SX9000: sky blue
  • 8020211 URJ000: purple
  • 8020211 WXH000: blue

SCOPE OF DELIVERY

Wall clock (A), Remote sensor (B), Instruction manual Required batteries: 3 x 1.5V battery (Size AA/LR6) and 2 x 1.5V battery (Size AAA/LR03) Batteries not included with purchase.

PARTS OVERVIEW

BRESSER-8020211B4K000-My-Timei-Wall-Clock-2

  1. Dial plate
  2. Clock hands (hours, minutes, seconds)
  3. Humidity display (indoor)
  4. Temperature display (indoor)
  5. Temperature display (outdoor)
  6. Wall mount
  7. Battery compartment 1 (Clock)
  8. Battery compartment 2 (Temp. and humidity display)
  9. M.SET button
  10. RESET button
  11. REC button
  12. °C/°F/DOWN button
  13. CH/UP button
  14. Function light
  15. Wall mount
  16. Battery compartment
  17. Table stand (fold-out)

GETTING STARTED/POWER SUPPLY

NOTE!
Note the right order before operating the device for the first time or when replacing the batteries. Make sure to place the batteries strictly according to the right polarities (+/-) as shown in the battery compartment.

  1. Remove the locking pin (A) from the clockwork. The clock can be operated only after the pin has been removed.
  2. Remove the cover from the wall clock battery compartment 2 (8).
  3. Insert one battery (1.5V, AA/LR6) into battery compartment 1 (7). Then place 2 batteries (1.5V, AA/LR6) into battery compartment 2 (8).
  4. Close the battery compartment 2 (8) again.
  5. Wait until the indoor temperature will be displayed.
  6. Remove the 4 fixing screws from the battery compartment (16) of the remote sensor with a small Phillips screwdriver and remove the cover.
  7. Insert 2 batteries (1.5V, AAA/LR03) into the battery compartment (16) of the remote sensor and close the battery compartment.
  8. During the installation process, place the remote sensor next to the base unit. Only position the remote sensor and the base unit at the desired place after a successful installation process and position it within the effective transmission range

TIME SETTING

NOTE!
After the clock received the DCF time signal the time will be set according to the Central European  time (CET). Summer and winter time change (andreverse) is also set automatically. Other deviating times can be set manually only.

Automatic time setting via DCF time signal
After inserting the batteries the time will be set automatically via DCF signal. This process may take a few minutes. During this process the clock hands will turn several times with interruption until they will display the right time.

Initiate to receive the DCF time signal manually
NOTE!
Use this function when e.g. automatic summer/ winter time change does not work or the wall clock temporarely receives no time signal.

  1. Press and hold the REC button (11) for 3 seconds to start manual search for the DCF signal.
  2. The clock hands will move to their start position (12:00 a.m.) and a the wall clock then tries to receive the signal.
  3. Wait approx. 2-5 minutes until the current time will be displayed.

Manual time setting
NOTE!
It is necessary to set the time manually in places where no radio signal is received.

  1. Press and hold the M.SET button (9) for approx. 3 seconds.
  2. When the minutes hand starts moving you can the set the time manually:
  3. Press the M.SET button shortly to set the time in minutes steps.
  4. Press and hold the M.SET button to set the time continously.
  5. Release M.SET button to stop manual setting and save the time automatically and exit manual time setting mode.

TEMPERATURE AND HUMIDITY DISPLAY

After inserting the batteries indoor humidity (3) and indoor temperature (4) will be displayed. After first data transmission from the remote sensor the outdoor temperature (5) will be displayed. This process may take a few minutes. You can switch the temperature display from degree Celsius to degree Fahrenheit by pushing the °C/°F/DOWN button (12) at the backside of the wall clock.

MOUNTING/POSITIONING

NOTE!
Make sure you have mounted or placed the device in a safe way. Otherwise the device may fall down and heavy damages can occur for which the manufacturer is not liable. The wall clock can be mounted on walls with the wall mount (6). The remote sensor also has a wall mount (15). Moreover it can be placed on plane surfaces with the fold-out table stand (17).

TROUBLESHOOTING

Signal disconnection
If without obvious reasons the display of the outdoor temperature goes blank, please check the following:

  1. The remote unit is still in place.
  2. The batteries of both the remote unit and main unit are not empty. Replace batteries with new ones if necessary.their voltage supply, effective range, and life span.
  3. All units required are within range and the path is clear of obstacles and interference. Shorten the distance if necessary

NOTE!
When the temperature falls below freezing point, the batteries of outdoor units will freeze, lowering

Transmission collision
Signals from other household devices, such as door bells, home security systems and entry controls, may interfere with those of this product and cause temporarily reception failure. This is normal and does not affect the general performance of the product. The transmission and reception of temperature readings will resume once the interference recedes.

Other malfunctions
If there is no response from the wall clock by keystrokes or if any other malfunctions occur perform the following steps.

NOTE!
With this procedure all received data will be deleted.

  1. Press RESET button (10) with a pointed instrument (e.g. pen).
  2. The clock hands will move to their start position (12:00 a.m.) and the wall clock then tries to receive the signal.
  3. Wait approx. 2-5 minutes until the current time will be displayed

CLEANING AND MAINTENANCE

Before cleaning the device, disconnect it from the power supply (remove batteries)! Only use a dry cloth to clean the exterior of the device. To avoid damaging the electronics, do notuse any cleaning fluid. Protect the device from dust and moisture. The batteries should be removed from the unit if it has not been used for a long time.

ENTSORGUNG
Dispose of the packaging materials properly, according to their type, such as paper or cardboard. Contact your local waste-disposal service or environmental authority for information on the proper disposal. Do not dispose of electronic devices in thehousehold garbage! As per Directive 2002/96/EC of the European Parliament on waste electrical and electronic equipment and its adaptation into German law, used electronic devices must be collected separately and recycled in an environmentally friendly manner.

EC DECLARATION OF CONFORMITY
Bresser GmbH declares that the device (MyTime iO Wall Clock / Art.No.: 80-20210) is in accordance with applicable guidelines and corresponding standards of the 2014/53/EUdirective. Find the complete declaration under: www.bresser.de/download/8020211000000/ CE/8020211000000_CE.pdf

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BRESSER User Manuals

Related Manuals