NEO TOOLS DIGITAL CALIPER 150MM Instruction Manual
- June 5, 2024
- NEO TOOLS
Table of Contents
DIGITAL CALIPER 150MM
Instruction Manual
|
---|---
Cat. No. 75-011
SAFETY RULES
To maintain safety use the product accordingly to its purpose and the information provided in this manual.
WARNINGS
- There are sharp edges on external measurement jaws (fig. 1/1), interna,l measurement jaws (fig. 1/2) and depth rod (fig. 1/3). To prevent cuts be very careful when using the caliper.
- Do not make measurements of rotating objects. Rotating parts (e.g. of a working machine) may cause body injuries. It also causes faster wear of the caliper measurement surfaces.
- Dthe o not apply voltage (e.g. of electric tester) to any part othe f the caliper, it may damage electronic assembly of the caliper.
- Remove the battery from the caliper, when it is not to be used for a long time.
TECHNICAL PARAMETERS
Measuring range: | 0+150 mm/0÷6 in |
---|---|
Resolution: | 0,01 mm / 0,0005 in |
Measurement accuracy: | ±0,02 mm / ±0,001 in |
Maximum measuring speed: | 1.5 m/s |
Measuring system: | Linear capacitive measuring system |
Display: | LCD |
Power supply: | Silver oxide (AgO) cell, 1.55V, SR44 type, 180 mAh capacity |
Current: | <20 pA |
Working temperature range: | 5°C ÷ 40°C |
Effect of humidity: | Negligible below relative humidity equal to 80% |
GENERAL OVERVIEW OF CALIPER WITH DIGITAL DISPLAY (fig. 1)
- External measurement jaws
- Internal measurement jaws
- Depth measurement rod
- Guide
- Battery compartment lid
- Display
- Slider lock screw
- Slider shift roller
- Unit toggle button (mm/inches)
- Zero adjustment button (ZERO)
- Slider
- ON/OFF button
CALIPER OPERATION
Ensure all caliper surfaces are free from grease, dust, dirt and filings
before starting to use the caliper. Use a cloth to wipe all measurement
surfaces of the caliper before starting to work. Use of any organic fluid is
forbidden. Ensure that all buttons and LCD displays operate correctly.
To make a measurement:
- loosen the slider lock screw (fig. 1/7),
- and press the ON/OFF button (fig. 1/12)
- select desired measurement unit by pressing the unit toggle button (fig. 1/9) —every time the button is pressed, measurement units change,
- use the slider shift roller (fig. 1/8) to move the jaws closer; the displayed value (fig. 1/6) should be zero; when it is not so, press the zero adjustment button (fig. 1/10),
- the display can be zeroed at any point within the measurement range.
Measuring external dimensions (fig. 2)
- Position measured object as close to the guide reference surface as possible,
- Move measurement jaws to contact the outer surfaces of the measured object.
- Measuring internal dimensions (fig. 3)
- Slide internal measurement jaws as deep as possible,
- Move measurement jaws to contact the inner surfaces of the measured hole.
- Measuring depth (fig. 4)
- Slide the depth measurement rod into the hole and position the guide perpendicular to the reference surface of the measurement.
Differential measurements (using display zero adjustments, fig. 5)
- Used for e.g. deviation from a standard, zeroing at a calibration dimension.
MAINTENANCE
- Keep the caliper dry and clean (any fluid may damage the slider) (fig 1/11).
- Measurement jaws should be delicately wiped with a cloth. Never use petrol, acetone or any other organic liquid.
- To save power when the caliper is not used for some time, switch it off with the OFF button (fig. 1/12).
- Except for the above, all other rules of operation for a standard caliper apply.
TROUBLESHOOTING
Fault | Cause | What to do |
---|---|---|
Digits flicker on the display | Battery voltage is below 1.45V | **Replace the |
battery (fig. 6)**
• unscrew screws fixing the battery compartment lid (fig. 1/5).
• replace the battery; position the new one keeping the polarity (positive
battery contact at the top)
Battery voltage is below 1.4 V
No digits on the display| Bad battery connection| Remove battery compartment
lid and check battery position
Displayed digits do not change when the slider is moved| Random fault in
caliper internal circuit| Remove the battery and reinstall it after
approximately 30 seconds
Accuracy lower than specified in technical parameters, but within 0.1 mm|
Sensor dirty| Deinstall slider cover and clean interior with compressed air (5
bar).
ENVIRONMENT PROTECTION
**** Do not dispose of electrically powered products with household wastes.
they should be utilized in proper plants. Obtain information on waste
utilization from your seller or local authorities. Used-up electric and
electronic equipment contains substances active in the natural environment.
Unrecycled equipment constitutes a potential risk for the environment and
human health.
****neo-tools.com
Distributeur : Gru pa Topex Spotka z o.o. Speika komandytowa ul. Pograniczna
2/4,
02-285 Warszawa (POLOGNE)
tol. 00 48 22 57 30 300
fax 00 48 22 57 30 400
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>