SCH Q4PS ATV-Quad Mounted Sprayer Instruction Manual
- June 5, 2024
- SCH
Table of Contents
Quad Mounted Sprayer
Instruction Manual
Manufacturers & Suppliers of Estate & Garden Machinery
TELEPHONE 01473 328272
FAX 01473 327177
www.schsupplies.co.uk
OPERATING INSTRUCTIONS
ATV/Quad Mounted Sprayer
Ref: Q4PS
DESCRIPTION
The sprayer has an integral 12-volt diaphragm pump powered by the quad’s own
battery via a connection lead. The sprayer has a capacity of 70 liters and is
supplied as standard with a hand lance and a 4-nozzle boom. The lance is ideal
for spot application of weed killers to nettles and docks. The lance and boom
are easily changed over by means of quick-release couplings.
All mounted sprayers are equipped with a 5-liter fresh water washing bottle.
4MPS SPECIFICATIONS
Tank Capacity | 70L (15 Gallons) |
---|---|
Spray Width | 2440mm (96”) |
Pump Delivery (Open Flow) | 7L per minute |
Pump Voltage | 12v DC bypass |
Pump Operation Pressure | 3.1 bar |
Maximum Fluid Temp | 54 °C |
Dry weight | 15kg approximately |
Full Weight | 84kg approximately |
SAFETY INSTRUCTIONS
- Never leave your sprayer where someone could trip or walk into it.
- Always make sure that the sprayer is firmly fixed to the vehicle.
- Never allow people to ride on the sprayer.
- Do not use the sprayer in close proximity to other people.
- Do not inhale the chemical.
- Do not allow the chemical to come into contact with food.
- Do not smoke while operating the sprayer with chemicals.
- Do not allow the spray to contaminate rivers or ponds.
- Do not allow children to play with the sprayer.
- Do not spray on windy days.
- Do not use tar-based products.
- Always store the sprayer in a safe place.
- Wear protective clothing and eyewear when operating the sprayer.
- Test and familiarise yourself with the sprayer by using plain water.
If in doubt, please call the SCH customer helpline at 01473 328272.
PREPARATION FOR USE
-
Mount the sprayer securely on the pannier
-
Connect the power lead to the battery (Brown to + Blue to -)
-
Choose the applicator: –
– To fit the hand lance connect it to the back delivery hose from the pump, the nozzle fitted will give a hollow cone spray
– The spray boom is fitted to the bracket at the rear of the sprayer and is held in position by a thumb screw (the nozzle should be approx. 400mm-500mm (16”-18”) above ground) -
Make sure the black delivery hose is secured firmly in place on the boom fitting
-
Commence spraying by operating the on/off toggle switch control. The pump may take time to dispense any trapped air in the system, when an even flow is achieved commence spraying.
TROUBLESHOOTING
-
If the pump fails to operate:
– Check the electrical connection -
If the pump fails to deliver: –
– Check suction hose is in the correct position.
– Check the filter head of the pump is clean.
– Check the ‘O’ ring on the filter bowl is in position.
– If the boom is fitted make sure the nozzles & filters are clear.
– Check the lance handle is clean by unscrewing the brass barrel, also ensure the nozzle & filter are clear.
MAINTENANCE
- Clean the unit after use.
- Always protect the unit from frost.
HAND LANCE
- Lance Body
- Lance Tube
- Nozzle Holder
- Nozzle Holder Cap
- Fitter
- Round Nozzle
- Wedge Nozzle
- Nozzle Strainer
- Complete Trigger Assy. Less Nozzle
PARTS LIST
Description | REF |
---|---|
Pump complete | MPS/Pump 2100 |
Pump filter complete | MPS / PFC |
On/off toggle switch | MPS / TS |
Tank Drain Tap | MPS / DT |
Brass Trigger Lance | MPS / TL |
Nozzle Holder for above | MPS / NH |
Nozzles – Red ‘V’ | MPS / RN |
Nozzles – Hollow Cone | MPS / CN |
Optional Extras | REF |
--- | --- |
Extension Hose – 4000mm c/w Brass Fittings | MPS / EXT4 |
Dribble Bar | MPS / DB |
Telescopic Lance – 2400mm Extended | MPS / TL |
4 Nozzle Spray Boom | MPS / 4NB |
Rose Head for above | MPS / RH |
Trigger Lance Brass Extensions – 450mm | MPS / TGEX |
12 – Volt Plug and Socket for permanent Wiring | MPS / PEX |
Tank Filter Cap | MPS / TFC |
Break Back Boom – 2400mm | MPS / BBB |
Please contact us for help with spare parts.
CALIBRATION
Calibrate as directed by the chemical manufacturers’ instructions
A SIMPLE GUIDE TO CHEMICAL / FEED APPLICATION
If the area to be sprayed is 3000 sq. meters. and according to the
instructions of the liquid bottle you select says sufficient for 1000 sq.
meters. Put 3 bottles in the tank and go over the area (north/south,
east/west) until the tank is empty.
Please note that having tested your sprayer with water as advised you may not
require a full tank of the mixture. Therefore, adjust requirements
accordingly.
UNDERSTANDING CALIBRATION
The law requires some 30,00 contractors and employed persons involved in
pesticide applications to obtain a Certificate of Competence.
This person will receive a good grounding in the safe and efficient use of
pesticides. The exemption rules are such that there will be a large pool of
people applying pesticides who, at best, will not have undertaken recent
training. A few far-sighted employers have incurred not inconsiderable costs
by including all their employers on the training courses and will more than
recoup on this investment over the years in increased efficiency.
Why Calibrate?
It is now a legal requirement for all users to adhere to the label
recommendations with regard to dosage rates, method of application, etc.
Besides being illegal to exceed the maximum recommended dose, getting the
application rate wrong can have distinctly adverse effects on the cash flow
and budgets.
Consistent overdosing of sites is not only environmentally undesirable; it
also increases the risk of damage to non-target species and run- of damage in
more sensitive areas. It can, even with a modest spraying program, cost
hundreds of pounds each year in wasted chemicals and unnecessary losses.
Underdosing, on the other hand, can be equally costly. If weeds, for example,
are not controlled at the first application, a second later application may be
necessary. This may involve higher rates, a more expensive chemical or even
hand weeding. Add to this the disruption to work schedules and it becomes
evident that careful monitoring and control of all application programs is
essential.
Correct application and efficient monitoring is only possible if all personnel
involved have a thorough understanding of calibration techniques.
TERMINOLOGY
Treated Area
All chemical data, whether in advisory leaflets or label recommendations, is
stated in liters or kilograms of product per treated area. The actual area to
be treated thus has to be calculated for budgeting, purchasing, job planning,
and calibration purposes.
Overall Application
The treated area is equal to the gross area
Band Application
The treated area is less than the gross area and is calculated thus: Bandwidth
x Band lengths x No of bands
Spot Application
The treated area is significantly less than the gross area and is calculated
thus:
Area of spot = 0.7855 x (diameter) ² (meters) (derived from πd ²) 4
The treated area (ha) = Area of spot x No of spots per ha ÷ 10,000
Quite obviously, the smaller the area that can be treated to achieve the
desired result; the less costly the operation. With the area calculated, the
variables involved can be determined in order to calibrate equipment to
complete the spraying operation in a safe and efficient manner.
Forward Speed
With overall and band applications, control of forwarding speed is critical in
determining how much chemical is applied. This will vary with the type of
terrain and must be realistically calculated. In flat terrain where unimpeded
progress is possible, forward speed will be greater than in undulating,
heavily vegetated conditions. In the latter, the trial may be necessary to
determine a constant work rate, which can be, maintained both up and downhill.
Swathe width
The width covered at each pass is known as the swathe width and will vary
with, for example, choice of the nozzle, operating pressure, and height of
application. Having selected the appropriate nozzle and operating pressure the
height selected must in the case of hand-held equipment be comfortable for the
operator.
Equipment is comfortable for the operator. With non-pressurized equipment,
such as CDA and gravity systems, there are obviously no operating pressures to
worry about.
Nozzle Output
Nozzle output is critical in all spraying operations and it is important to
select a nozzle type appropriate to the viscosity of the concentrate being
applied/swathe width required.
Flow Rate
The flow rate will vary with nozzle type, viscosity, pressure, and ambient
temperature at the time of application.
After selecting the most appropriate nozzle for the operation adjustment to
pressurize equipment will be necessary to achieve the desired flow rate. The
flow rate in powered machinery can be controlled by engine speed and/or
internal pressure adjustment.
Application Rate
Spray coverage of the target being sprayed should be sufficient to give an
even application of the correct dose of pesticide on the area to be treated.
The manufacturer’s recommendations must be followed and where there is a
choice of options, i.e., high, medium, low, very low volumes, select the most
appropriate volume to achieve the desired result.
Tank Dilution
From the application rate, it is possible to calculate the amount of pesticide
required per full tank. Pesticide per fill (litres) = Tank volume (litres) x
Pesticide volume (litres/ha ÷ Diluent’s volume (litres/ha) .
CALIBRATION TECHNIQUE
Having determined the above, the next step is to calibrate the actual
equipment chosen to apply the required amount of concentrate on the target
area.
Each type of application obviously has its own calibration method which must
be studied and closely followed, but in general, the following notes for
spraying equipment will hold good.
It is most important to understand that each applicator will vary slightly
from others of the same type and manufacture. Thus, each piece of equipment
must be individually calibrated.
The selected nozzles should be filled with water and the correct operating
pressure selected.
The output of each nozzle should then be measured by spraying into a measuring
jug for a set period of time, e.g., one minute, to give the nozzle output in
liters/minutes.
As output will vary from nozzle to nozzle, in boom equipment the output from
each nozzle should be checked. In larger boom equipment, at least four nozzles
should be checked- one from each section and the output calculated
accordingly. If nozzle outputs on boom equipment vary by more than 5%, the
faulty nozzles should be replaced.
If output varies by a small amount from the calculated output, with some types
of equipment, altering the operating pressure can rectify this. Where the
output varies by a large amount, the calibration calculations should be re-
checked and the nozzle type changed if necessary.
With all equipment, the application pattern is checked and swathe width is
measured by treating an area of dry soil, concrete, etc.
Once the actual output is known, the forward speed can be calculated, in the
case of liquid sprayers, thus: Forward speed (meters/hour) Measured nozzle
output liters/minute) x 600,000 x (no of nozzles) Volume rate (liters/ha) x
Swathe width (meters) The equipment can then be filled with the recommended
mixture of pesticides and dilatants. Never add pesticide concentrate direct to
an empty tank, always half-fill the tank with dilatants prior to adding the
concentrate, and mix thoroughly.
A suitable test area. e.g., A 100m strip can be sprayed at this speed. At the
end of this, the actual application rate should be determined by topping up
the tank using a measuring jug. The forward speed can then be adjusted to
ensure that the concentrate is applied at the correct rate.
The serviceability of the equipment can be tested at the same time. Leaks are
environmentally unacceptable and waste expensive. Blockages lead to patchy
results and both make efficient monitoring impossible.
The full calibration process is only necessary when equipment has not been
used for a while, after servicing, or after changes in nozzles and pressure
are made.
It is, however, good practice to check the actual application rate at the
commencement of each day’s work and after lunch. Adjustments can be made as
appropriate.
Each employee will require access to a stopwatch and tape measure in order
that they can monitor their own output. If resistance is met then this is a
good indication that the employee has not understood the reasons behind the
calibration process and further training is needed.
The process can be tedious but as operators become more familiar with the
techniques, the loss in application time is reduced and more than offset by
the improved results obtained.
Much can, of course, be done by management to simplify the task by the
production of job sheets clearly setting out the details of each task and
providing space for records to e ept. These when returned, can be filed and
the statutory requirement for adequate records to be kept met.
MANAGEMENT TASKS
- Analyze the objectives of the operation
- Select the most effective chemical to achieve these objectives
- Check the manufacturers’ recommendations to ensure that it is suitable for the task and select an appropriate application rate
- Select the most efficient equipment to apply the chemical
- Calculate the dilution rate per tank: Pesticide per fill Tank volume (1) x Pesticide rate (1/ha) ÷ Dilatant’s rate (1/ha)
- Select an appropriate tank pressure for pressurized equipment
- Select the correct nozzle to give the required swathe width
- Calculate the gross area
- Calculate the ACTUAL area to be treated. Overall application: Treated area = gross area Band application (ha): Treated area = Bandwidth (m) x Band length x no of bands Width between row (m) Spot treatment (ha): Treated area = [0.7855 diam² (m)] x no spots/ha ÷ 10,000
- Calculate an optimum forward speed based on the equipment to be used, the terrain type, and the ease of movement
- Issue comprehensive yet simple instructions to staff
- Ensure that a record of the operation and its effectiveness is kept and any problems investigated fully
SUPERVISORS TASKS
- Read notes provided and check details
- Check weather including wind speed and re-schedule operation if unsuitable conditions prevail
- Ensure all operatives are issued with the correct safety wear, that this is serviceable and worn
- Fill the sprayer with water and set it to the correct pressure
- Measure nozzle flow rates using a measuring jug Nozzle output (1/min) = quantity of spray in a jug (ml) x 60,000 ÷ Time (sec)
- Adjust pressure to give calculated output (if possible). If significant variation from the calculated output, check calibration calculations and, if necessary, change nozzles
- Spray an area of concrete or dry soil to determine the actual swathe width and for an even droplet pattern. With a boom, equipment ensures that the spray pattern from each nozzle overlaps correctly
- Check for leaks and blockages. Blockages should only be cleared by using compressed air and never with wire!
- Using the actual nozzle output and the actual swathe width determine the actual forward speed required to apply the correct quantity of chemical Forward speed = Nozzle output x 600,000 x No of nozzles ÷ Volume rate x swathe width
- Compare this with the optimum speed and recalculate the operation if necessary
- Fill the tank with the correct quantity of concentrate/dilatants
- Mark out an appropriate test area, spray, and calculate the actual application rate. Adjust the forward speed as appropriate
- Issue clear and simple instructions based on the actual output of the equipment
- Monitor the operation and ensure that regular checks on output are made
- Ensure that tank washings and surplus chemicals are disposed of safely in accordance with the law
- Ensure that adequate records are maintained on the basis of the actual operating parameters.
INSTALLATION & SERVICE INFORMATION
DESCRIPTION FLORET
Industrial Duplex II Pumps are designed for a wide range of applications and
are constructed from a selection of materials suitable for handling a broad
range of chemicals. The Duplex II series of diaphragm pumps are self-priming
and can be run dry without harm. They are intended for intermittent duty
cycles but can be run continuously for short periods of time. The higher the
duty cycle the shorter the expected life of the pump. Typical pump uses are
liquid transfer, spraying. cooling, circulation, fitration and dispensing.
OPERATION
To start and prime the pump, the discharge line must be open allowing trapped
air to escape thus avoiding the potential of airlock. The pressure switch will
shut off the pump automatically when the discharge valve is dosed and the
pressure has risen to the switch OFF set point. The pressure switch will
restart the pump when a valve is opened and the discharge line pressure drops
to the ON set point of the pressure switch.
DEMAND OPERATION (INTERMITTENT DUTY)
Demand Operation is considered an “intermittent duty” application. The maximum
intermittent duty cycle is that which will cause the motor to reach its
maximum thermal limits. Once the maximum thermal limit is reached, the motor
must be allowed to settle to a lower temperature ideally being ambient before
resuming operation. Running the pump at or near the maximum thermal limit for
an extended period of time will shorten the life of the pump and may result in
immediate pump failure.
BYPASS OPERATION (IF EQUIPPED)
Models equipped with an external bypass system are designed to pump at high
pressures while at low or high flow rates. Models equipped with a bypass only
will continue to run until the power is manually turned off. The Duplex II
pumps are not recommended for continuous duty service due to limited motor
brush life. Operation at lower pressures and temperatures, however, will
extend overall pump service life.
MOUNTING
The FLOJET Duplex II Series pumps are self-priming. Vertical prime may vary depending on the fluid viscosity, and suction tube size. foot valve and pump configuration. The pump should be mounted in a dry and adequately ventilated area. If mounted within an enclosure, provisions to cool the motor may be necessary.
PREVENTATIVE MAINTENANCE TIPS
If pumping a liquid other than water the pump should be flushed with water (if
applicable) after each use. Sealers and Teflon tape acting as a lubricant can
cause cracked housings or stripped threads due to over-tightening. Care should
be used when applying sealers: the tape may enter the pump inhibiting valve
action. causing no prime or no shut-off conditions. Failures due to foreign
debris are not covered under warranty. Before freezing conditions occur. the
pump must be liquid-free or winterized with proper anti-freezing chemicals. If
mounting the pump in an outdoor environment the pump should be shielded from
water. dust, sunlight and wash down spray. Do not assume chemical
compatibility. If the fluid is improperly matched to the pumps Elastomers. the
pump may fail to prime. have low pressures or the pressure switch may not shut
off.
PLUMBING
Use a flexible hose of the correct pressure rating that is compatible c with the fluid to be pumped. Tubing should be a minimum of 3/8″ (9.5 mm) ID and at least 20 inches (508 mm) in length to avoid excess stress on the pump ports. Do not crimp or kink the tubing. The pump head maybe rotated in 90′ increments to simplify plumbing. FLOJET does not recommend the use of metal fittings. standard plastic male and female threaded fittings can be acquired at commercial plumbing supply stores. FLOJET also distributes plastic bath fittings through our distributors (form no. F100-001). The use of check valves in the plumbing system could interfere with the priming ability of the pump. If a check valve is installed in the plumbing it must have a cracking pressure of no more than 2 PSI (.14 bar). Use of a minimum 40-mesh strainer or filter in the pump inlet line will prevent foreign debris from entering the system. Failures due to foreign debris entering the pump will not be covered under the limited warranty. Note: Inlet pressure must not exceed 30-PSI (2.1 bar) maximum.
WARNING
Risk of an electrical shock!
When wiring electrically driven pumps. follow all electrical and safety codes.
as well as the most recent National Electrical Code (NEC) and the Occupational
Safety and Health Act (OSHA).
Make certain the power source conforms to the pump voltage. Be sure all power
is disconnected before installation.
The pump should be wired into an individual (dedicated) circuit, controlled
with a ULJC-UL certified double pole switch rated at or above the fuse ampere
indicated on the pump motor label.
On 115-volt AC pumps. the black wire lead is live or common. the white lead
wire is neutral and the green/yellow is ground.
On 230-volt AC pumps the brown wire lead is live or common. the blue wire is
neutral and the green/yellow is ground. On 12 and 24-volt pumps the red lead
is positive and should be connected to the battery plus (+) terminal. The
black lead is ground and should be connected to the battery minus (-)
terminal. Use T6 AWG wire minimum. Use a fuse to protect the system wiring and
components.
Improper duty cycle and/or rapid start-stop conditions caused by undersized
spray nozzles will cause the internal thermal breaker (if equipped) to trip.
or can cause premature motor failure due to excessive heat.
WARNING
DO NOT USE IT TO PUMP FLAMMABLE FLUIDS, GASOLINE, KEROSENE FUEL OIL, ETC.
DO NOT USE A PUMP IN A EXPLOSIVE ENVIRONMENT
DIMENSIONAL DRAWING
Inches (Millimeters) Dimensional tolerances ± 0.06 inches Consult the
factory if precise details are required.
DEMAND PUMP | A | B | C |
---|---|---|---|
Minimum Dimension | 3. (64) | 4. (101) | 8.00 (203) |
Maximum Dimension | 3. (71) | 5. (122) | 9. (219) |
BYPASS PUMP | |||
Minimum Dimension | 3.(64) | 3. (83) | 727 (185) |
Maximum Dimension | 3. (71) | 4. (89) | 8. (196) |
KEY | DESCRIPTION | KEY | DESCRIPTION |
---|---|---|---|
1 | Pump Screws | 7 | Motor Rear End Bell Assembly |
2 | Pressure Switch Assembly | 8 | Base Plate/Grommet Assembly |
3 | Check Valve Assembly (With 0 Ring) | 9 | Upper Housing (Switch By-Pass) |
4 | Diaphragm/Cam Bearing Assembly | 10 | Upper Housing (By-Pass Only) |
5 | Diaphragm | 11 | Bearing Cover |
6 | Motor Assembly (Less Base Plate) | ‘SPARE PARTS AVAILABLE |
DISASSEMBLE
Pump Housing (2)
-
Disconnect power to the pump motor.
-
Remove pressure switch cover (2) and remove wire leads from switch assembly.
-
Remove the four recessed pump-housing screws (1) located on top of the pump housing (8 or 9).
-
Remove the pump housing (9 or 10) from the diaphragm/lower housing assembly.
Check Valve Assembly (3) — Follow steps 1 through 4. -
The check valve housing and o-ring 0) are located in the upper housing (9 or 10) or on the diaphragm cam assembly (4).
-
If in upper housing, remove by placing a small flat blade screwdriver between the upper housing and check valve housing and pry out. Diaphragm/Cam Assembly (4)
-
Remove two deep-set Phillips head screws (4).
-
Rotate bearing cover (11), so access notch is aligned with cam bearing set screw, loosen set screw with a 1/8″ Allen wrench, and slide pump lower housing assembly from the motor shaft.
-
After removing the cam bearing from the outer piston set, the inner piston screws are now visible, remove both flat head screws. The outer piston set can now be removed from the two inner pistons.
TROUBLESHOOTING
Failure to Prime – Motor operates, but no pump discharge
- Restricted intake or discharge line. Open all line valves. check for “jammed” check valves, and clean dogged lines.
- Air leak in intake line.
- Punctured pump diaphragm,
- Defective pump check valve.
- Crack in the pump housing
- Debris in check valves.
Motor Fails to Turn On
-
Pump or equipment not plugged in electrically.
-
Loose wiring connection.
-
Pressure switch failure
-
Defective motor or rectifier.
-
Frozen cam” bearing.
Pump Fails to Turn Off after Discharge valves are Closed. -
Depletion of available liquid supply.
-
Punctured pump diaphragm.
PRODUCT WARRANTY
Flojet warrants this product to be free of defects in material and/or
workmanship for a period of one year after purchase by the customer from
Flojet. During this one-year warranty period. Flojet will at its option, at no
charge to the customer, repair or replace this product if found defective,
with a new or reconditioned product but not to indude costs of removal or
installation. No product will be accepted for return without a return material
authorization number. All return goods must be shipped with transportation
charges prepaid. This is only a summary of our Limited Warranty. For a copy of
our complete warranty, please request Form No. 100-101.
REASSEMBLE
Diaphragm/Cam Assembly (4)
-
Place hex stem of inner pistons through the diaphragm and the openings in the bearing cover (11) and into the outer piston set
-
Center pistons in the diaphragm and install two flat head screws.
-
Place cam bearing over outer piston set aligning locating pins into the holes of the cam bearing housing.
-
Install round head screws and tighten securely.
Bearing Cover (11) -
Coat motor shaft with grease prior to installing the diaphragm/earn bearing assembly (4) to motor
-
Attach cam bearing assembly to the motor shaft by aligning shaft indentation with set screw and tightening securely. (Rotate access notches down toward the base plate.)
-
Install and tighten 2 Phillips head screws to the motor (torque to 25 inch-pounds).
Check Valve Assembly (3) -
Install check valve with new o-ring over the pistons in the diaphragm, discharge side up (side with center side up).
Pump Housing (9 or 10) -
Place pump housing (9 or 10) over the check valve and align the four screw holes with the bearing cover.
-
Instill the four Phillips head screws (1) into the bearing cover and cross tighten securely.
-
Discharge line leak.
-
Defective pressure switch.
-
Insufficient voltage to pump.
-
Debris in check valves.
Low Flow and Pressure. -
Air leak at the pump intake.
-
Accumulation of debris inside pump and plumbing.
-
Worn pump bearing (excessive noise).
-
Punctured pump diaphragm.
-
Defective rectifier or motor
-
Insufficient voltage to pump.
Pulsating Flow -Pump Cycling On and Off -
Restricted pump delivery. Check discharge lines. fittings, valves, and spray nozzles for clogging or undersizing.
SERVICE KITS
Kits are readily available to repair standard Duplex II senes pumps. To insure
that the correct kits are received the model number and all nameplate data
must be included with the order Contact a FLOJET distributor or FLOJET
directly to order the necessary repair kits.
RETURN PROCEDURE
Prior to returning any product to Flojet. call customer service for an
authorization number. This number must be written on the outside of the
shipping package. Place a note inside the package with an explanation
regarding the reason for return as well as the authorization number. Include
your name, address, and phone number.
WARRANTY
Your sprayer is guaranteed for 12 months from date of purchase. This guarantee
covers faults that may occur from defective parts or manufacture.
This warranty only covers the sprayer for products that may be diluted with
water. Tar-based products are not recommended.
If you are missing your free brochure, contact us on
01473 328272, email sales@schsupplies.co.uk,
or
visit our website www.schsupplies.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>