FLIR VS80 High Performance Videoscope User Manual
- June 5, 2024
- FLIR
Table of Contents
FLIR VS80 High-Performance Videoscope
Introduction
The probes covered in this manual are designed for use with the VS80 High- Performance Videoscope. The probes are controlled by the touch-screen icons and control buttons on the VS80. The VS80 user manual and additional translations of this probe manual are available from the support site (see the Support section). Please update the VS80 firmware before use, as explained in the VS80 manual. This will ensure optimal functionality and full compatibility with your camera probe.
Probe Descriptions
The probes are described in the following sections, see the Specifications and Safety sections for additional information. The VS80 offers many useful and convenient features including capturing still images and video, changing camera views, connecting with smart devices, and controlling worklights. Please refer to the VS80 user manual for complete information.
VS80C55-1RM General Purpose Camera Probe
The general purpose camera probe head is 5.5 mm in diameter and its probe
length is 3.3 ft (1 m). The camera resolution is 640 * 480.
- VS80 connector
- Probe
- Probe head
- Front view of the camera lens and work lights
VS80CHD–55-1RM HD Camera Probe
The HD camera probe head is 5.5 mm in diameter and its probe length is 3.3 ft
(1 m). The camera resolution is 1280 * 720.
- VS80 connector
- Probe
- Probe head
- HD camera lens and work lights
VS80C2-49-1RM Dual HD Camera Probe
The dual HD camera probe head is 4.9 mm in diameter and its probe length is
3.3 ft (1 m). The camera resolution is 1280 * 720.
- VS80 connector
- Probe
- Side view camera and work lights
- Forward view camera
VS80CIR—21 Thermal IR Camera Probe
The VS80CIR-21 offers a Lepton 3.5 IR camera with a 3.3 ft (1 m) probe. The
VS80 displays the camera image and the temperature of targeted surfaces and
offers s selectable display palette, a temperature alarm, and other features.
- VS80 connector
- Probe
- Orientation mark. This represents the top of the image
- IR camera lens
Connecting the Probe
The steps below explain how to safely connect the probe to the VS80 monitor.
Always turn the VS80 power off before replacing the probe.
- Align the white dot on the probe connector with the white dot on the monitor connector.
- Plug the probe into the monitor unit, ensuring proper alignment and full insertion.
- Tighten the collar nut to secure the connection. Do not overtighten.
Safety
Safety Note
Please read and understand all safety cautions before use.
CAUTION
Do not insert the probe into flammable liquid or gas. This product is
designed for industrial use only. It is not intended for use in hu-man or
other biological inspection.
CAUTION
To clean the probe, wipe with a soft cloth dampened with a mild detergent
and clean water. Do not use abrasives, corrosives (alcohol), or solvents to
clean the probe. Use a high quality lens cleaning fluid and a lint-free swab
to clean the camera and worklight lenses. Do not disassemble the product,
damage to the product and electrical shock may occur. Avoid direct sun
exposure. Store in a cool, dry, and well-ventilated area.
- The probe contains sensitive circuitry that controls the optics and electronics of the camera. Do not strike the probe or allow it to impact objects forcefully.
- For digital probes ONLY, immerse probes only in approved liquids (see the Specifications section). This does NOT apply to the IR Camera (VS80CIR-21). The IR Camera probe must NOT be immersed in liquid.
Specifications
Digital Camera Specifications
Camera resolution| 1280 (H) * 720 (V) for VS80C2–49–1RM and VS80CHD-55–1RM
640 (H) * 480 (V) for VS80C55–1RM
---|---
Frame rate| 30 frames per second (fps), approximately
Probe Diameter| 5.5 mm for VS80CHD-55–1RM and VS80C55– 1RM
4.9 mm for VS80C2–49–1RM
Field of View| 90°
Depth of Field| 0.4 to 4.0 in (10 to 100 mm)
Probe tip length| 0.78 in (20 mm) for VS80CHD-55–1RM and VS80C55–1RM
0.84 in (21.3 mm) for VS80C2–49–1RM
Probe length| 3.3 ft (1 m)
Side-view camera| VS80C2–49–1RM only
LED Worklights| Worklights are controlled from the VS80
Four forward and two side work lights on VS80CHD-55–1RM and VS80C55–1RM
Five forward and one side work light on VS80C2– 49–1RM
Operating temperature| 32 to 140℉ (0 to 60℃)
Storage temperature| –4 to 140℉ (-20 to 60℃)
---|---
Relative Humidity| 10 to 95 % non-condensing
Approved liquids for digi- tal camera probes| Approved for use in brake and
transmission fluid, diesel fuel, unleaded gasoline, engine oil, and CPC
hydraulic fluid (46AWS). This does NOTap- ply to the IR camera probe
VS80CIR-21
Ingress rating| Probe tip and body: IP 67 (IEC 60529)
Protected from submersion in water up to 3.3 ft (1 m) for 30 minutes maximum. In use: rain, splashes, and accidental submersion
IR Camera Specifications
IR Camera type | Thermal Lepton 3.5 |
---|---|
Resolution | 160 (H) * 120 (V) |
Frame rate | 8.7 Hz |
Probe diameter | 0.4 in (10.4 mm) probe |
0.7 in (19 mm) camera
Probe tip length| 1 in (25 mm)
Field of View (FOV)| 71°
Operating temperature| 32 to 122℉ (0 to 50℃)
Storage temperature| –4 to 140℉ (-20 to 60℃)
Shock| 25 g (IEC 60068-2-29)
Vibration| 2 g (IEC 60068-2-6)
Drop-proof| 6.6 ft (2 m)
Water-proof| Probe tip and body: IP 67 (IEC 60529)
Protected from submersion in water up to 3.3 ft (1 m) for 30 minutes maximum. In use: rain, splashes, and accidental submersion
Warranty and Support
Three-Year Limited Warranty
This product is protected by FLIR’s 3-Year Limited Warranty. Visit
www.flir.com/testwarranty to read the 3-Year Limited Warranty document.
CUSTOMER SUPPORT
Customer Support Telephone List|
https://support.flir.com/contact
---|---
Repair, Calibration, and Technical Support|
https://support.flir.com
Wlastebsitepage
http://www.flir.com Customer support http://support.flir.com Copyright ©
2022, FLIR Systems, Inc. All rights reserved worldwide.
Disclaimer
Specifications subject to change without further notice. Models and
accessories are subject to regional market considerations. License procedures
may apply. Products described herein may be subject to US Export Regulations.
Please refer to exportquestions@flir.com
with any questions.
References
- support.flir.com
- Thermal Imaging, Night Vision and Infrared Camera Systems | Teledyne FLIR
- support.flir.com
- support.flir.com/contact