VONROC GP808AA Pump Pre-Filter Instruction Manual
- June 5, 2024
- VONROC
Table of Contents
VONROC GP808AA Pump Pre-Filter
SAFETY INSTRUCTIONS
Read the enclosed safety warnings, the additional safety warnings and the instructions. Failure to follow the safety warnings and the instructions may result in electric shock, fire and/or serious injury. Save the safety warnings and the instructions for future reference. The following symbols are used in the user manual or on the product:
- Read the user manual.
- Denotes risk of personal injury, loss of life or damage to the tool in case of non-observance of the instructions in this manual.
- Not intended for use by children.
- Protect the pre-filter against frost.
SAFETY WARNINGS
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES OR LACK OF EXPERIENCE AND KNOWLEDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAIN- TENANCE SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION. Please read these instructions carefully and thoroughly before using this appliance and keep them for future reference. It is very important that you understand how to use this appliance safely so please take the time to familiarise yourself with the requirements as outlined in these instructions.
- If you are in any doubt what so ever about using this appliance, we strongly recommend that you employ the services of a suitably qualified person.
- Keep children and pets well away from the work area and never allow children to use this appliance at any time.
- When not in use, keep this appliance stored in a safe place out of reach of children.
- Never leave the appliance unattended when in use.
- Using water pressure must not be higher than 10 bar / 1 MPa to avoid the damage of product.
- Do not use the pre-filter for drinking water.
- The temperature of the liquid conveyed may not exceed 35 °C.
PRODUCT INFORMATION
The pump pre-filter is intended for private use for household water supply and irrigation of gardens, it is not intended for commercial use. It is solely intended for clear and rain water.
Model No. | GP808AA |
---|---|
Application | Pre-filtering of water (suction side of the pump) |
Filter element height | 25 cm |
Max. operating pressure | 10 bar / 1 MPA |
Mesh width | 0.15 mm |
Max. water temperature | 35°C |
Water inlet connection | G1″ internal thread |
Water outlet connection | G1″ internal thread |
Threaded coupling size | G1″ external thread |
Replacement pre-filter | GP810AA |
Weight | 1.04 kg |
DESCRIPTION
The numbers in the text refer to the diagrams on page 2-3.
- Water inlet
- Top section
- Water outlet
- Transparant housing
- Filter
- Spanner
- Couplings
- Screws
- Wall bracket
- Plug (air outlet)
- Suction hose (not included)
INSTALLING
Installing the filter (Fig. A, B, C)
- Insert the filter (5) into the transparent housing (4) and screw the housing onto the top section (2) by using a spanner (6).
- Apply thread seal tape (Teflon tape) to the threaded coupling (7).
- Screw the coupling (7) airthight into the filter outlet (3), as shown on figure B1.
- If the coupling of the suction hose (11) has a female thread, an extra coupling (7) is needed. Apply thread seal tape (Teflon tape, not included) to the threaded coupling (7).
- Screw the coupling (7) airthight into the filter inlet (1), as shown on figure B2.
- Screw the pre-filter airthight on the water inlet of the garden pump, as shown on figure C. When the filter touches the ground, it is recommended to use a wooden block between the pump and the ground. The feet of the pump can be bolted to the wooden block.
Wall bracket (Fig. A, C)
The supplied wall bracket makes it possible to attach the filter to a pole or
wall.
- Put the wall bracket (9) on the top section (2).
- Mount the wall bracket (9) by tightening the four screws (8).
- Mount the wall bracket (9) to a pole or wall by tightening three screws or bolts (not included).
Attaching the suction hose (Fig. A, C)
- Don’t use any hose connection system fittings or standard water hoses on the suction side! A suction hose (11) set with suitable coupling (G1” thread) and foot valve must be used. The foot valve prevents the return flow of the water at the end of the pumping process.
- 25mm, 32mm or 38mm (inner diameter) suction hose (11) must be used to achieve maximum flow rate.
- The suction hose (11) should be as short as possible.
- Fill suction hose (11) with clean tap water.
- Apply thread seal tape (Teflon tape, not included) to the threaded suction hose coupling.
- Screw the suction hose coupling airthight into the water inlet (1).
Filling the pump and filter with water (Fig. A, C)
Air in the filter will stop the garden pump from working properly.
- Unscrew and remove the air outlet (10) plug.
- Fill the pump with clean tap water. Do not overfill the pump. See the pump manual. Check that the filter is also filled with water.
- Place the air outlet (10) plug back, do not overtighten.
- The pre-filter is now ready for use.
MAINTENANCE
Cleaning (Fig. A, D)
For optimal performance it is recommended to regularly change the filter (5)
depending on level of use.
- Carefully remove the transparant housing (4) by using a spanner (6).
- Use a mild soap and water solution to clean the filter (5) and the transparant housing (4) and afterwards rinse with clean water.
- Insert the filter (5) into the transparent housing (4) and screw the housing onto the top section (2) by using a spanner (6).
STORAGE AND FROST POTECTION
The pre-filter and accessories that are not completely drained can be destroyed by frost. Completely drain the pre-filter and accessories and protect them against frost. Keep this appliance in well-ventilated dry premises with temperature not going below +5°C. When not in use, keep this appliance stored in a safe place out of reach of children.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>