APsmart RSD-S-PLC Rapid Shutdown Device
IMPORTANT SAFETY INSTRUCTIONS
This manual contains important instructions to be followed during installation and maintenance of the APsmart RSD-S-PLC and Transmitter. To reduce the risk of electrical shock and ensure the safe installation and operation of the APsmart RSD-S-PLC and Transmitter, the following symbols appear throughout this document to indicate dangerous conditions and important safety instructions.
Safety Instructions
- Do NOT disconnect the PV module from the RSD-S-PLC without first disconnecting the AC power.
- Only qualified professionals should install and/or replace the APsmart RSD-S-PLC.
- Perform all electrical installations in accordance with local codes.
- Before installing or using the RSD-S-PLC, please read all instructions and cautionary markings in the technical documents.
- Be aware that the body of the operating RSD-S-PLC is a heat sink and can reach high temperature. To reduce risk of burns, do not touch the body of the RSD-S-PLC.
- Do NOT attempt to repair the RSD-S-PLC. If it fails, contact APsmart Customer Support to obtain an RMA number and start the replacement process. Damaging or opening the RSD-S-PLC will void the warranty.
The power supply of the Transmitter-PLC and the inverter MUST be on the same AC branch circuit as the inverter to meet rapid shutdown requirements.
Qualified personnel
Person adequately advised or supervised by an electrically skilled person to enable him or her to perceive risks and to avoid hazards which electricity can create. For the purpose of the safety information of this manual, a “qualified person” is someone who is familiar with requirements for safety, electrical systems and EMC and is authorized to energize, ground, and tag equipment, systems, and circuits in accordance with established safety procedures. The inverter and balance of system may only be commissioned and operated by qualified personnel.
RSD PRODUCTS
RSD-S-PLC
- Meets NEC 2017&2020 (690.12) requirements
- Executes rapid shutdown of system when Transmitter-PLC signal is absent
- Meets SunSpec requirements
The RSD-S-PLC meets SunSpec requirements, maintaining normal function by continually receiving a heartbeat signal from the APsmart Transmitter. The RSD-S-PLC executes rapid system shutdown when the Transmitter signal is absent. Users can manually execute rapid shutdown using the Transmitter breaker switch.
TRANSMITTER PRODUCTS
Transmitter-PLC
- Meets NEC 2017&2020 (690.12) requirements
- Switching off Transmitter-PLC results in rapid shutdown of the output of PV modules
- Meets SunSpec requirements
- Equipped with single/dual core
- Optional 85-264VAC power supply
- Optional 180-550VAC power supply
Transmitter-PLC-Outdoor Kit
- Meets NEC 2017&2020 (690.12) requirements
- Switching off Transmitter-PLC results in rapid shutdown of the output of PV modules
- Meets SunSpec requirements
- Equipped with single/dual core
- Optional 85-264VAC power supply
- Optional 180-550VAC power supply
SYSTEM WIRING DIAGRAM
- The APsmart Rapid Shutdown System Transmitter-PLC is part of a rapid shutdown solution when paired with APsmart RSD-S-PLC, a PV module rapid shutdown unit. While powered on, the
- Transmitter-PLC sends a signal to the RSD-S-PLC units to keep the PV modules connected and supplying energy.
- RSD-S-PLC units automatically enter rapid shutdown mode when the Transmitter-PLC is switched off and resume energy production when power is restored to the Transmitter-PLC. This solution complies with NEC 690.12 specifications for 2017 & 2020 and supports the SunSpec signaling for rapid shutdown.
- The Transmitter-PLC includes one or two cores and an optional power supply: 85-264VAC for residential, 180-550VAC for commercial.
- Transmitter-PLC Outdoor Kit includes a Transmitter-PLC with one or two cores, outdoor enclosure,
85-264VAC or 180V-550VAC power supply. It could be used in residential or commercial projects.
- RSD-S-PLC
- Transmitter-PLC
- Inverter
- RSD-S-PLC
- Transmitter-PLC-Outdoor Kit
- Inverter
- RSD-S-PLC
- Transmitter-PLC-Outdoor Kit
- Inverter
- Emergency stop button box(optional): Press the emergency stop button, the transmitter AC power supply is disconnected, the RSD closes the output, and the system rapid shutdown.
RSD-S-PLC INSTALLATION
- RSD-S-PLC
- Inverter*
- Inverter in diagram includes an integrated SunSpec-certified Rapid Shutdown Transmitter.
INSTALLATION NOTES
Installation MUST comply with local regulations and technical rules:
- Perform all electrical installations in accordance with local codes.
- Be aware that only qualified professionals should install and/or replace the RSD-S-PLC.
- Before installing or using an RSD-S-PLC, please read all instructions and warnings in the technical documents and on the inverter system itself as well as on the PV array.
- Be aware that installation of this equipment includes the risk of electric shock.
- Do not touch any live parts in the system, including the PV array, when the system has been connected to the electrical grid.
- Ensure the PV module and inverter have been disconnected before installing an RSD-S-PLC.
- Be sure to verify the voltage and current specifications of your PV module match with those of the RSD-S-PLC.
- The maximum open circuit voltage of the PV module must not exceed the specified maximum input voltage of the APsmart RSD-S-PLC.
Additional installation components from APsmart
- DC extension cable (sold separately)
Required parts and tools to complete the installation
In addition to your PV array and its associated hardware, you will need a
torque wrench and a Phillips screwdriver.
Step 1: Install the RSD-S-PLC.
NOTE: Do not place the RSD-S-PLC (including DC connectors) where exposed to the sun, rain or snow, even gap between modules. Allow a minimum of 3/4’’(1.5cm.) between the roof and the bottom of the RSD-S-PLC to allow proper air flow.
Step 2: Connect the input connectors of the RSD-S-PLC to the junction box, the device output DC voltage is within the range of 0.6 to 1v.
NOTE: Do not short-circuit the RSD-S-PLC output connectors, otherwise it will be damaged.
RSD-D cable length
Note: The output cable length of triad junction box PV module should be no less than 0.9m.
Note: The output cable length of integrated junction box PV module should be no less than 0.9m.
NOTE: When installing RSD-D cable, the bending radius of the cable near the casing must be greater than 50 mm.
**Step 3: Connect the output connectors of the RSD-S-PLC in series to the string, the string open-air DC voltage is within the range of (0.6 ~ 1v) X
RSD-S-PLCs. (This range may vary due to different on-site environment.)**
NOTE: Do not connect homerun to inverter before finishing all strings
connections and tests.
NOTE: Please use the same type of DC connector as the RSD in the system. The
RSD damage caused by using different type of DC connector will not be covered
by the warranty.
TRANSMITTER-PLC INSTALLATION
Warning: The cores need to be fixed to prevent swing and causing the
damage to the Transmitter-PLC.
The power supply of the Transmitter-PLC and the inverter must be on same AC
branch circuit as inverter to meet rapid shutdown requirements.
During operation, the Power LED should be lit and the Signal LED should be
blinking. If the Transmitter-PLC fails to work, the Signal LED will not be
blinking. If the Power LED is also not lit, check the power supply first.
Note: Install the RSD-S-PLC before powering the Transmitter-PLC.
- Mount Transmitter-PLC and power supply on DIN rail
- Connect DC leads from power supply to Transmitter-PLC
- Connect single/dual core(Core 1 and Core 2) to Transmitter-PLC
Place rapid shutdown system label no more than 1m (3ft) from Transmitter-PLC or AC disconnect if not at same location.
Note: Install the RSD-S-PLC before powering the Transmitter-PLC.
Note: The waterproof jacket and related accessories are not configured
before delivery and customers need to buy by themselves.
-
Pass either positive or negative cables through cores
(either both positive cables or both negative cables. Do not use one positive and one negative cable.) -
Connect wires to AC side of power supply
Max number of Strings Per Core :
DC cable Diameter(without connector) | Φ5.9mm | Φ6.35mm | Φ7mm | Φ8.6mm |
---|---|---|---|---|
29mm Core | ≤ 15 | ≤ 15 | ≤ 14 | ≤ 10 |
11mm Core | ≤ 6 | ≤ 5 | ≤ 4 | ≤ 2 |
Max string length : 30 modules
Max current per core: 150A
Max cable length from inverter(+) to inverter(-) : 1000ft (300m)
Note: The Outdoor Kit was not punched before delivery and customer need to make it themselves according to the actual situation. The figure is only for reference.
TECHNICAL DATA—RSD-S-PLC
TECHNICAL DATA—TRANSMITTER-PLC
TECHNICAL DATA—TRANSMITTER-PLC-OUTDOOR KIT
ORDERING INFORMATION
Transmitter-PLC
RSD-S-PLC
600 Ericksen Ave NE, Suite 200 Seattle, WA 98110 | +1-737-218-8486 |+1-866-374-8538 | support@APsmartGlobal.com | APsmartGlobal.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>