Features
CSR is designed to be used in automatic soldering processes. Two pairs of
grippers can be used to hold the cartridges while they are not in use.
It can work in combination with JBC Automatic Soldering Irons (TRA) and
the new cartridges for automation (R245 and R470 ranges).
Assembly
CSR needs to be fixed in the robot workplace area. Use a DIN912 M6 screw and
the mounting hole as shown below.
The gripper actuators must be connected to an air circuit by using tube
connections A and B.
Gripper Actuator
Fluid| Air
Applicable tubing| Ø 4mm
Operating pressure| 1,5 to 7 bar
A. Tube connection to fix Cartridge.
B. Tube connection to release Cartridge.
Work Position Adjustment
CSR body can be pivoted 35º on both sides to suit the inclination of your
soldering head in every job necessity. Use a 5mm Allen key to loosen the bolt
and pivot the CSR body manually.
Note the angle indicator around the bolt area. Tighten the bolt for holding
the body in the desired position. The soldering head must be set to the same
angle.
Compatibility
Cartridge Stand | Cartridge Range | Control Unit | Soldering Irons |
---|---|---|---|
R245 | R470 | UCR245 | UCR470 |
CS2R245 | |||
CS2R470 |
Compatible Cartridges
Find the Cartridge models that best suit your soldering needs on
www.jbctools.com
Tool Position Adjustment
The cartridge plate can be set to four different positions.
The flat faces of the plate and the cartridge must match.| Use a 1,5 mm Allen
key to loosen the three indicated screws.
Evenly pull the plate holder and become the cartridge plates.
---|---
|
Insert the cartridge plates to any of the four positions you need.
The smaller squared shape must face upwards.| Assemble the plate holder to its
initial position and tighten the three screws evenly.
|
Centering Jig
In order to align CSR to the soldering iron and set the cartridge pick-up
points to use JBC´s centering jig.
Install both, lower and upper centering jigs, on CSR and the soldering iron as
shown.|
---|---
Adjust the soldering iron position until the centering jigs are aligned.
It must be possible to move in and out smoothly.|
Insert the upper centering jig completely into the lower centering jig.
Set this point as the pick-up point position.
From this point on, the soldering iron should do a linear movement when
inserting or removing cartridges.|
Dimensions
Work Place Example
*Not included, sold separately
Maintenance
- Before carrying out maintenance, always unplug the equipment.
- Use a damp cloth to clean the equipment. Alcohol can only be used to clean the metal parts.
- Periodically check that the metal parts of the equipment are clean.
- Periodically check all cables and tube connections.
- Replace any defective or damaged part. Use original JBC spare parts only.
- Repairs should be performed only by a JBC-authorized technical service.
- Under normal operating conditions, the air gripper’s lifespan is 10 million cycles. It is recommended to replace it at the end of its lifespan.
Safety
It is imperative to follow safety guidelines to prevent electric shock,
injury, fire, or explosion.
- Do not use the equipment for any other purpose.
- Do not leave the appliance unattended when it is on.
- Be sure that the power supply is disconnected before changing any spare parts.
- The temperature of accessible surfaces may remain high after the unit is turned off. Handle with care.
- Heat can cause inflammable products to ignite even when not visible.
- Avoid flux coming into contact with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when working to avoid personal harm.
- Utmost care must be taken with liquid tin waste, which can cause burns.
Notes ———–
Specifications
CSR
Cartridge Stand for Robot
Ref.: CS2R245-B / CS2R470-B
– Operating pressure: 1,5 – 7 bar / 20 – 100 psi
CS2R245-B
– Total Net Weight: 789 g / 1.74 lb
– Package Dimensions/Weight: 221 x 136 x 126 mm / 1004 g
(L x W x H) 8.70 x 5.35 x 4.96 in / 2.21 lb
CS2R470-B
– Total Net Weight: 807 g / 1.78 lb
– Package Dimensions/Weight: 221 x 136 x 126 mm / 1045 g
(L x W x H) 8.70 x 5.35 x 4.96 in / 2.30 lb
Complies with CE standards.
ESD safe.
Warranty
JBC’s 2-year warranty covers this equipment against all manufacturing defects,
including the replacement of defective parts and labor.
The warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must be returned, postage
paid, to the dealer where it was purchased.
This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at
the end of its life must be collected and returned to an authorized recycling
facility.
www.jbctools.com
0027877-26052022
Documents / Resources
| JBC
CS2R245-B CSR Cartridge Stand for
Robot
[pdf] Instruction Manual
CS2R245-B, CSR Cartridge Stand for Robot, CS2R245-B CSR Cartridge Stand for
Robot, CS2R470-B
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>