Avanti MOTR14K3S-IS 1.4 cu. ft. OTR Microwave Oven Instruction Manual

October 27, 2023
Avanti

Avanti MOTR14K3S-IS 1.4 cu. ft. OTR Microwave Oven

Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-
product

General Information

INTRODUCTION
This installation guide will show you how to install your new over-the-range microwave

BEFORE YOU BEGIN

Read these instructions completely and carefully.

  • IMPORTANT – Save these instructions for local inspector’s use.
  • IMPORTANT – Observe all governing codes and ordinances.
  • Note to the installer – Be sure to leave these instructions with the consumer.
  • Note to the consumer – Keep these instructions for future reference.
  • Skill Level – Installation of this appliance requires basic mechanical and electrical skills.
  • Proper installation is the responsibility of the installer.
  • Product failure due to improper installation is not covered under the warranty.

IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT – PLEASE READ CAREFULLY. FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED TO AVOID SEVERE OR FATAL SHOCK.

This product requires a three-prong, properly grounded outlet for safe operation. If not properly grounded, or if the outlet box does not meet the electrical requirements noted (under ELECTRICAL REQUIREMENTS), a qualified electrician should be employed to correct any deficiencies. The power cord of this appliance is equipped with a three-prong (grounding) plus which mates with a standard three-prong (grounding) wall receptacle to minimize the possibility of electric shock hazard from this appliance. Where a standard two-prong wall receptacle is encountered, it is very important to have it replaced with a properly grounded three-prong wall receptacle installed by a qualified electrician.

DO NOT, UNDER ANY CIRCUMSTANCES, CUT, DEFORM, OR REMOVE ANY OF THE PRONGS FROM THE POWER CORD. DO NOT USE WITH AN EXTENSION CORD.

NOTE:
For easier installation and personal safety, it is recommended that two people install this product.

CAUTION:
For personal safety, remove the house fuse or open the circuit breaker before beginning installation to avoid sever or fatal shock injury. For personal safety, the mounting surface must be capable of supporting the cabinet load, in addition to the added weight of this 50-70 pound (22.6 – 31.7 kilogram) product, plus additional oven loads of up to 50 pounds (22.6 kgs) for a total weight of 100 – 120 pounds (45.2 – 54.3 kgs). For personal safety, this product cannot be installed in cabinet arrangements such as an island or a peninsula. It must be mounted to BOTH a top cabinet and a wall.

ELECTRICAL REQUIREMENTS
The product rating for your microwave is 120 V AC, 60 Hz, 13.5 Amps and 1.5 Kilowatts. This product must be connected a supply circuit of the proper voltage and frequency. Wire size must conform to the requirements of the National Electrical Code or the prevailing local code for this kilowatt rating. The power supply cord and plug should be brought to a separate 20 ampere branch circuit single grounded outlet. The outlet box should be located in the cabinet above the microwave oven. The outlet box and supply circuit should be installed by a qualified electrician and conform to the National Electrical Code or the prevailing local code.Avanti-MOTR14K3S-IS-1.4-cu.-ft
.-OTR-Microwave-Oven-fig-1

NOTE:

  • If you need to install ducts, note that the total duct length of 31/4″x 10″ rectangular or 6″ diameter round duct should not exceed 140 equivalent feet.
    Outside ventilation requires a HOOD EXHAUST DUCT. Read the following carefully.

  • It is important that venting be installed using the most direct route and with as few elbows as possible. This ensures clear venting of exhaust and helps prevent blockages. Also, make sure dampers swing freely and nothing is blocking the ducts.

Exhaust connection:
The hood exhaust has been designed to made with a standard 3 1/4″x10″ rectangular duct. If a round duct is required, a rectangular-to-round transiting adaptor must be used. Do not use less than a 6″ diameter duct.

Maximum duct length:
For satisfactory air movement, the total duct length of 3 1/4″x10″ rectangular or 6″diameter round duct should not exceed 140 equivalent feet.

Elbows, transitions, wall and roof caps, etc.,
present additional resistance to and are equivalent to a section of straight duct which is longer than their actual physical size. When calculating the total duct length, add the equivalent lengths of all transitions and adaptors plus the length of all straight duct sections. The chart below shows you how to calculate total equivalent ductwork length using the approximate feet of equivalent length of some typical ducts. Avanti-MOTR14K3S-IS-1.4-cu.-ft
.-OTR-Microwave-Oven-fig-2

IMPORTANT:
If a rectangular-to-round transition adaptor is used, the bottom corners of the damper will have to be cut to t, using the tin snips , in order to allow free movement of the damper. Equivalent lengths of duct pieces are based on actual with any vent hood.

DAMAGE-SHIPMENT/INSTALLATION

  • If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.
  • If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.
  • If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and installer.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-3

You will find the installation accessories contained in a packet with the unit. Check to make sure you have all these parts.

NOTE: Some extra parts are included.

TOOLS YOU WILL NEED

Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-
fig-4

MOUNTING SPACE

Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-
fig-5

NOTES:

  • The space between the cabinets must be 24” wide and free of obstructions.
  • If you are going to vent your microwave oven to the outside, see the Hood Exhaust section for exhaust duct preparation.
  • When installing the microwave oven beneath smooth, flat cabinets, be careful to follow the instruction for power cord clearance. Make sure that you leave enough space for the power cord clearance.

Step-by-Step Installation Guide

PLACEMENT OF THE MOUNTING PLATE

REMOVING THE MICROWAVE OVEN FROM THE CARTON / REMOVING THE MOUNTING PLATE

  1. Open the carton and remove the upper foam from the box, but remember to keep the accessories.
  2. Pull the oven out of the carton and remove the plastic bag carefully.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-7
  3. Take the mounting bracket out from the upper foam.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-8

FINDING THE WALL STUDS

  1. Find the wall studs, using one of the following methods.
    • Wall stud finder – a magnetic device that locates nails.
    • Use a hammer to tap lightly across the mounting surface to find a sold sound. This will indicate a wall stud location.
  2. After locating the stud(s), find the center by probing the wall with a small nail to find the edges of the wall stud. Then place a mark halfway between the edges. The center of any adjacent wall studs should be 16” to 24” from this mark.
  3. Draw a line down the center of the wall studs.

DETERMINING THE TOP LINE OF THE REAR WALL TEMPLATE LOCATION UNDER YOUR CABINET.

There are (3) different types of bottoms on cabinets:

  1. Flat bottom CabinetAvanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-10

  2. Recessed frame cabinet bottom
    Must align with the back frame of the cabinet bottom

  3. Recessed frame cabinet bottom with front overhang.

TOP LINE OF REAR WALL TEMPLATE
Must align with below cabinet bottom the same distance as the front overhang of the cabinet bottom.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-
fig-12

Your cabinets may have decorative trim that interferes with the microwave installation. Remove the decorative trim to install the microwave properly and to make it level.

THE MICROWAVE MUST BE LEVEL
Use a level to make sure the cabinet bottom is level. If the cabinets have a front overhang only, with no back or side frame, top line of rear wall template must align with below cabinet bottom, the same distance as the front overhang depth. This will keep the microwave level.

  1. Measure the inside depth of the front overhand.
  2. Draw a horizontal line on the back wall an equal distance below the cabinet bottom as the inside depth of the front overhang.
  3. For this type of installation with front overhand only, alight the top line of rear wall template with this horizontal line, no touching the cabinet bottom as described in step D.

ALIGNING TOP LIEN OF REAR WALL TEMPLATEAvanti-MOTR14K3S-IS-1.4-cu.-ft
.-OTR-Microwave-Oven-fig-13

CAUTION:
WEAR GLOVES TO AVOID CUTTING FINGERS ON SHARP EDGES

  1. Using a tape measure, draw a vertical line on the wall at the center of the 24” wide space.

  2. Tape the rear wall template on the cabinet wall, and align the center markers on the rear wall template to the centerline on wall, making sure it is level and that the top line of the rear wall template is butted up against the bottom edge of the upper cabinet.

  3. According to the shape of the cabinet, the location of the rear wall template is compliant with the content C “determining top line of rear wall template location under cabinet”

  4. While taping the rear wall template on the wall draw circles on the wall at holes A, B, and C (see illustration above /actual plate marked with arrows). THREE HOLES MUST BE USED FOR MOUNTING. (If there are 2-wall studs in right and left sides based on the center line FOUR holes must be used for mounting).

  5. Remove the rear wall template and check the marking based on the actual mount plate (centerline, hole A, B, C).

  6. Drill holes on the circle marks (A, B, C)

  7. Drill a 3/16” hole at C for wood screw and two 5/8” holes at A, and B for toggle bolts.
    Note: DO NOT MOUNT THE PLATE AT THIS TIME.

  8. If the rear wall template is damaged or unusable, measure and mark the wall with the dimensions described in step E.

MARK THE REAR WALL OF THE CABINET WITHOUT THE REAR WALL TEMPLATEAvanti-
MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-14

  1. The Bottom edge line of the Mounting Plate must be 17 1/8″ (435mm) from the Bottom edge Line of the Upper cabinet and must be level.
  2. Mounting plate end holes must be 16 17/25″ (423.8mm) from the Bottom edge Line of the Upper cabinet and must be on an equal line with each other. They must each be 9 9/ “25 (237.8mm) from the center line.

INSTALLATION TYPES (Choose A, B, or C)
This microwave oven is designed for adaptation to the following three types of ventilation:

  • Outside Top Exhaust (Vertical duct)
  • Outside Back Exhaust (Horizontal duct)
  • Recirculating (Non-Vented Ductless)

Note: This microwave is shipped assembled for Recirculating.

  • OUTSIDE TOP EXHAUST (VERTICAL DUCT
  • OUTSIDE BACK EXHAUST (HORIZONTAL DUCT)
  • RECIRCULATING (NON-VENTED DUCTLESS)

OUTSIDE TOP EXHAUST (VERTICAL DUCT)

INSTALLATION OVERVIEW

  • A1: Attached is the mounting plate to the wall.
  • A2: Use the top cabinet template for the preparation of the cabinet.
  • A3: Check for proper damper operation.
  • A4: Mount the microwave oven.
  • A5: Adjust the exhaust adaptor.
  • A6: Connect Ductwork.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-18

ATTACH THE MOUNTING PLATE TO THE WALL

Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-
fig-19

Attach the mounting plate to the wall using the wing nuts and machine screws (3/16” x 3”). At least one wood screw must be used to attach the mounting plate to a wall stud.

  1. Insert the machine screws (3/16” x 3”) into the mounting plate through the holes designed to go into drywall and attached the toggle wings to ¾” onto each machine screw (3/16” x 3”).

  2. Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the plate.
    CAUTION:
    BE CAREFUL TO AVOID PINCHING FINGERS BETWEEN THE BACK OF THE MOUNTING PLATE AND THE WALL.

  3. Tighten all bolts. Pull the mounting plate away from the wall to help tighten the bolts.

USE TOP CABINET TEMPLATE FOR PREPARATION OF TOP CABINET
You need to drill holes for the top support screws, a hole large enough for the power cord to fit through, and a cutout large enough for the exhaust adaptor.

  • Read the instructions on the TOP CABINET TEMPLATE
  • Tape it underneath the bottom of the top cabinet.
  • Drill the holes, following the instructions on the TOP CABINET TEMPLATE.

CAUTION: Wear safety goggles when drilling holes in the cabinet

CHECK FOR PROPER DAMPER OPERATION

  • Place the microwave in its upright position, with the top of the unit facing up.
  • The exhaust adapter is only used for the top exhaust and outside back exhaust. It is not included on those units shipped for recirculation exhaust only.
  • Make sure the tape security of the damper is removed and the damper pivots easily before mounting the microwave.
  • Attached is the exhaust adapter to the blower plate by sliding it into the guides. Secure the adapter with one sheet metal screw (provided).
  • You will need to make adjustments to assure proper alignment with your house exhaust duct after the microwave is installed.

MOUNT THE MICROWAVE OVEN
FOR EASIER INSTALLATION AND PERSONAL SAFETY, WE RECOMMEND THAT TWO PEOPLE INSTALL THIS MICROWAVE OVEN.

IMPORTANT:
DO NOT GRIP OR USE THE HANDLE DURING INSTALLATION. IF FILLER BLOCKS ARE NOT USED, CASE DAMAGE MAY OCCUR FROM OVER-TIGHTENING SCREWS.

NOTE:
If your cabinet is metal, use the nylon grommet around the power cord to prevent cutting the cord. We recommend using filler blocks if the cabinet front hangs below the cabinet bottom shelf. When mounting the microwave oven, thread the power cord through the hole in the bottom of the top cabinet. Keep it tight throughout steps 1 – 3, do not pinch or lift the oven by pulling the cord.

  1. Lift the microwave, tilt it forward, and hook slots at the back bottom edge onto four lower tabs of the mounting plate.

  2. Rotate the front of the oven up against the cabinet bottom.

  3. Attach the microwave oven to the top cabinet.

  4. Insert 2 self-aligning machine screws (1/4” x 20 x 3”) through the outer top cabinet holes.

  5. Temporarily secure the oven by turning the screw at least two full turns after the threads have engaged. (It will be completely tightened later.) Be sure to keep power cord tight. Be careful not to pinch the cord, especially when mounting flush to the bottom of the cabinet.
    The filler block is only used for recessed cabinets and front overhand cabinets(see types of cabinet previously explained in this manual), you should place the filler block to the cabinet bottom before installing the oven.

  6. Tighten the outer screws to the top of the microwave oven. (During tightening screws, hold the microwave oven in place against the wall and the top cabinet.

  7. Install the grease filters. See the User’s Guide packed with the microwave.

ADJUST THE EXHAUST ADAPTOR
Open the top cabinet and adjust the exhaust adaptor to connect to the house duct.

CONNECTING DUCTWORK

  1. Extend the house duct down to connect to the exhaust adaptor.
  2. Seal exhaust duct joints using duct tape.

OUTSIDE BACK EXHAUST (HORIZONTAL DUCT)

INSTALLATION OVERVIEW

  • B1: Preparing the rear wall template for the outside back exhaust.
  • B2: Attach the mounting plate to the wall
  • B3: Use the top cabinet template for the preparation of the top cabinet.
  • B4: Adapting microwave blower for outside back exhaust.
  • B5: Mount the microwave oven.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-30

PREPARING THE REAR WALL TEMPLATE FOR THE OUTSIDE BACK EXHAUST

You need to cut an opening (12” x 4” square hole) in the rear wall template for the outside exhaust

  • Read the instruction on the rear wall template.
  • Tape it to the rear wall, lining up with the holes previously drilled for holes A and B in the wall plate.
  • Cut the opening, following the instruction of the rear wall template.

ATTACH THE MOUNTING PLATE TO THE WALL Avanti-MOTR14K3S-IS-1.4-cu.-ft
.-OTR-Microwave-Oven-fig-32

Attach the mounting plate to the wall using the wing nuts and machine screws (3/16” x 3”). At least one wood screw must be used to attach the mounting plate to a wall stud.

  1. Insert the machine screws (3/16” x 3”) into the mounting plate through the holes designed to go into drywall and attached the toggle wings to ¾” onto each machine screw (3/16” x 3”).
  2. Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the plate.

CAUTION:
BE CAREFUL TO AVOID PINCHING FINGERS BETWEEN THE BACK OF THE MOUNTING PLATE AND THE WALL.

Tighten all bolts. Pull the mounting plate away from the wall to help tighten the bolts.

USE TOP CABINET TEMPLATE FOR PREPARATION OF TOP CABINET
You need to drill holes for the top support screws, a hole large enough for the power cord to fit through, and a cutout large enough for the exhaust adaptor.

  • Read the instructions on the TOP CABINET TEMPLATE
  • Tape it underneath the bottom of the top cabinet.
  • Drill the holes, following the instructions on the TOP CABINET TEMPLATE.

CAUTION: Wear safety goggles when drilling holes in the cabinet

ADAPTING MICROWAVE BLOWER FOR OUTSIDE BACK EXHAUST

  1. Remove and save the screw that holds the blower motor to the microwave, and lift up the blower plate.

  2. Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-34

  3. Remove “ Parts A “ with Nipper or Scissors

  4. Rotate the blower unit counterclockwise 180º

  5. Rotate the blower unit clockwise 90º

  6. Place the blower unit back into the opening.
    CAUTION:
    Do not pull or stretch the blower unit wiring. Make sure the wires are not pinched.
    NOTE:
    The blower unit exhaust openings should match the exhaust openings on the rear of the microwave oven.

  7. Replace the blower plate in the same position.

  8. Attach the exhaust adapter to the rear of the oven by sliding it into the guides at the top center of the back of the oven.
    Push in securely until it is in the lower blower motor screw. Take care to assure that the damper hinge is installed so that it is at the top and that the damper swings freely.

  9. Secure the blower motor unit to the microwave with screw as before.

  10. Secure the blower plate to the microwave with a screw. Replace the plower plate in the same position.

MOUNT THE MICROWAVE OVEN
FOR EASIER INSTALLATION AND PERSONAL SAFETY, WE RECOMMEND THAT TWO PEOPLE INSTALL THIS MICROWAVE OVEN.

IMPORTANT:
DO NOT GRIP OR USE THE HANDLE DURING INSTALLATION. IF FILLER BLOCKS ARE NOT USED, CASE DAMAGE MAY OCCUR FROM OVER-TIGHTENING SCREWS.

NOTE:
If your cabinet is metal, use the nylon grommet around the power cord to prevent the cutting of the cord. We recommend using filler blocks if the cabinet front hangs below the cabinet bottom shelf. When mounting the microwave oven, thread the power cord through the hole in the bottom of the top cabinet. Keep it tight throughout steps 1 – 3, do not pinch or lift the oven by pulling the cord.

  1. Lift the microwave, tilt it forward, and hook slots at the back bottom edge onto four lower tabs of the mounting plate.

  2. Rotate the front of the oven up against the cabinet bottom.

  3. Attach the microwave oven to the top cabinet.

  4. Insert 2 self-aligning machine screws (1/4” x 20 x 3”) through the outer top cabinet holes.

  5. Temporarily secure the oven by turning the screw at least two full turns after the threads have engaged. (It will be completely tightened later.) Be sure to keep power cord tight. Be careful not to pinch the cord, especially when mounting flush to the bottom of the cabinet.
    The filler block is only used for recessed cabinets and front overhand cabinets(see types of cabinet previously explained in this manual), you should place the filler block to the cabinet bottom before installing the oven.

  6. Tighten the outer screws to the top of the microwave oven. (During tightening screws, hold the microwave oven in place against the wall and the top cabinet.

  7. Install the grease filters. See the User’s Guide packed with the microwave.

RECIRCULATING (NON-VENTED – DUCTLESS)

INSTALLATION OVERVIEW

  • C1: Attach the mounting plate to the wall
  • C2: Use top cabinet template for the preparation of the top cabinet.
  • C3: Adapting blower for recirculation.
  • C4: Mount the microwave oven.
  • C5: Change the Charcoal Filter

ATTACH THE MOUNTING PLATE TO THE WALL

Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-
fig-48

Attach the mounting plate to the wall using the wing nuts and machine screws (3/16” x 3”). At least one wood screw must be used to attach the mounting plate to a wall stud.

  1. Insert the machine screws (3/16” x 3”) into the mounting plate through the holes designed to go into drywall and attached the toggle wings to ¾” onto each machine screw (3/16” x 3”).
  2. Place the mounting plate against the wall and insert the toggle wings into the holes in the wall to mount the plate.

CAUTION:
BE CARFUL TO AVOID PINCHING FINGERS BETWEEN THE BACK OF THE MOUNTING PLATE AND THE WALL.

Tighten all bolts. Pull the mounting plate away from the wall to help tighten the bolts.

USE TOP CABINET TEMPLATE FOR PREPARATION OF TOP CABINET
You need to drill holes for the top support screws, a hole large enough for the power cord to fit through, and a cutout large enough for the exhaust adaptor.

  • Read the instructions on the TOP CABINET TEMPLATE
  • Tape it underneath the bottom of the top cabinet.
  • Drill the holes, following the instructions on the TOP CABINET TEMPLATE.

CAUTION: Wear safety goggles when drilling holes in the cabinet

ADAPTING MICROWAVE BLOWER FOR RECIRCULATION

  1. Remove and save the screw that holds the blower motor to the microwave, and lift up the blower plate.
  2. Carefully pull out the blower unit. The wires will extend far enough to allow you to adjust the blower unit.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-50
  3. Rotate blower unit 90º
  4. Place the blower unit back into the opening.
  5. Replace the blower plate in the same position.
    CAUTION:
    Do not pull or stretch the blower unit wiring. Make sure the wires are not pinched.
    NOTE:
    The blower unit exhaust openings should match the exhaust openings on the rear of the microwave oven.

MOUNT THE MICROWAVE OVEN
FOR EASIER INSTALLATION AND PERSONAL SAFETY, WE RECOMMEND THAT TWO PEOPLE INSTALL THIS MICROWAVE OVEN.

IMPORTANT:
DO NOT GRIP OR USE THE HANDLE DURING INSTALLATION. IF FILLER BLOCKS ARE NOT USED, CASE DAMAGE MAY OCCUR FROM OVER-TIGHTENING SCREWS.

NOTE:
If your cabinet is metal, use the nylon grommet around the power cord to prevent cutting the cord. We recommend using filler blocks if the cabinet front hangs below the cabinet bottom shelf. When mounting the microwave oven, thread the power cord through the hole in the bottom of the top cabinet. Keep it tight throughout steps 1 – 3, do not pinch or lift the oven by pulling the cord.

  1. Lift the microwave, tilt it forward, and hook slots at the back bottom edge onto four lower tabs of the mounting plate.

  2. Rotate the front of the oven up against the cabinet bottom.

  3. Attach the microwave oven to the top cabinet.

  4. Insert 2 self-aligning machine screws (1/4” x 20 x 3”) through the outer top cabinet holes.

  5. Temporarily secure the oven by turning the screw at least two full turns after the threads have engaged. (It will be completely tightened later.) Be sure to keep the power cord tight. Be careful not to pinch the cord, especially when mounting flush to the bottom of the cabinet.
    The filler block is only used for recessed cabinet and front overhand cabinets(see types of cabinet previously explained in this manual), you should place the filler block to the cabinet bottom before installing the oven.

  6. Tighten the outer screws to the top of the microwave oven. (During tightening screws, hold the microwave oven in place against the wall and the top cabinet.

  7. Install the grease filters. See the User’s Guide packed with the microwave.

CHANGE THE CHARCOAL FILTER
Charcoal filter is used for non-vented, recirculated installation. The filter should be changed every 6 – 12 months depending on use.

  1. Remove the two screws of the louver which is on the top of the oven by using a #1 Phillips head screwdriver.
  2. Open the door then remove the louver and take the used charcoal filter out.
  3. Install the new charcoal filter. When properly installed, the wire mesh of the filter should be visible from the front.Avanti-MOTR14K3S-IS-1.4-cu.-ft.-OTR-Microwave-Oven-fig-59
  4. Replace the louver and the screws.