ARROW Pressure Injectable One-Lumen PICC pre-loaded User Manual
- June 5, 2024
- Arrow
Table of Contents
CDC-35541-TTS
4Fr.
55cm catheter length1
Lumen .018 inch dia. spring-wire guide
Pressure Injectable One-Lumen PICC pre-loaded
Pressure Injectable One-Lumen PICC pre-loaded with Arrow® VPS TipTracker™ Stylet
Contents:
1:OneLumen Taper Free® Catheter:4Fr.(1.45mmOD)x55cm, Pressure In injectable,
Blue Flex Tip®, Contamination Guard, Arrow® VPS Tip Tracker™ StyletandT-Port
Connector
1:Glide Thru™ Peel-Away Sheath:4Fr.x2-3/4″(7cm)Radiopaque over 4Fr. Dilator
1:Spring-Wire Guide, Nitinol, Marked:.018″(0.46mm)dia.x17-3/4″(45cm)(Straight
Soft Tipon One End-Straig htStiff Tipon Other)with Arrow Advancer
1:Injection Needle: Safety Glide™ 125Ga.x5/8″(1.60cm)RW
1:Safety Introducer Needle: Echogenic21Ga.x2-3/4″(7cm)TW1:Blunt
FillNeedle:18Ga.x1-1/2″(3.81cm)
1:Introducer Needle: Echogenic 21Ga.x2-3/4″(7cm)TW
1:Syringe:10mLLuer-Lock
1:Syringe:3mLLuer-Lock4:10mLLuer-LockPre-Filled Saline Syringe
1:Skin Protectant Prep
1:5mL1%Lidocaine HCl Solution and AlcoholPrep
1:3mL Applicator2%CHGand70%IPA Chlora Prep® 2One-Step Solution
1:3mL Applicator2%CHG and 70%IPA Chlora Prep®2One-Step Solution with Hi-
LiteOrange™Tint
1:DustCap: Non-Vented
1:Second Site™ Adjusta bleb: CatheterClamp
1:Second Site™Adjust able Hub: Fastener
1:Sharps Away® Disposal Cup
1:Sharps Away® IILocking Disposal Cup
1:Catheter Trimmer1:Towel:24″x36″(61cmx91cm)
1:Maximal Barrier Drape™ withtwo 13cm(5″)x15cm(6″) fenestrations
1:Towel1:SafetyScalpel:#11
1:Sterile Procedure Sign
1:Patient ID Card1:ChartSticker
1:PatientInformationBooklet
1:Medication Label:1% Lidocaine
1:Checklist/CLIPSheet
2:Paper Tape Measure
1:Tourniquet
1:Foam Electrodes (3perpack)
10:Gauze Pad:2″x2″(5cmx5cm)
10:Gauze Pad:4″x4″(10cmx10cm)
1:Dressing:Tegaderm®315.5cmx10cm
1:SurgicalAppare
l: Impervious Gown
1:Dressing: BIOPATCH®4
1:Dressing: STATLOCK® 5Catheter Stabilization Device
1:SurgicalAppare
l: Mask with EyeShield
1:Surgical Apparel
l: Bouffant Cap
1:Surgical Apparel
l: Mask
1:Equipment Cover:13cmx244cm(5″x96″)
1:Tape: Steri-Strip®3
1:Hemo Hopper® Fluid Receptacle
1:T-Piece Cover1 Atrademarkof Becton, Dickinson and Company.
2Aregistered trademark of Care Fusion or one of its subsidiaries.
3Aregistered trademark of 3M Company.
Not made with natural rubber latex.
Store between 20 — 25°C (68 — 77°F). Arrow International provides the enclosed
medication label(s) for your convenience. Please ensure that these labels are
applied to the correct syringe and corresponding medication.
Contraindications: The Pressure Injectable P1CC is contraindicated wherever
there is the presence of device-related infections or the presence of
thrombosis in the intended insertion vessel or catheter pathway. A clinical
assessment of the patient must be completed to ensure no contraindications
exist.
4A registered trademark of Johnson & Johnson Corporation.
5A registered trademark of C. R. Bard, Inc.
Lumen| Priming Volume* (mL)| Gravity Flow Rate†
(mL/hr)| Pump Flow Rate††
(mL/hr)| MAX Pressure Injection
Flow Rate** (mL/sec)
---|---|---|---|---
Distal( 17 Ga.)| 0.58| 946| 5720| 5
- Priming volumes are approximate and are done without accessories. †Flow rate values are approximate and are determined using deionized water at 100 cm head height. †† Pump flow rates are determined at a maximum pump pressure of 10 PSIG and represent approximate flow capabilities.
** Pressure injection flow rates are determined at the injector pressure setting of 300 psi maximum using media of 11.8 centipoise viscosity, with 152 cm pressure tubing.
LBL056560 R01 (2022-04)