Laserliner 082 042 Thermo Spot Plus Infrared Thermometer Instruction Manual
- June 5, 2024
- Laserliner
Table of Contents
- Function / Application
- General safety instructions
- Dimension
- Product Overview
- Instruction
- Continuous measurement / Hold
- MAX display
- Setting the emission coefficient
- Table of emission coefficients
- Technical data
- EU directives and disposal
- SERVICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Laserliner 082 042 Thermo Spot Plus Infrared Thermometer Instruction Manual
Function / Application
The ThermoSpot Plus is an infrared thermometer with an adjustable emission coefficient that can be used for measuring the temperature of a wide range of surfaces without having to make contact with them. The instrument measures how much electromagnetic energy is emitted in the infrared wavelength range and uses this information to calculate the surface temperature.
General safety instructions
- Attention: Do not look into the direct or reflected beam.
- The laser may not get into the hands of children!
- Do not point the laser beam towards persons.
- If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
- Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
- The device must only be used in accordance with its intended purpose and within the scope of the specifications. Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
Dimension
Product Overview
a. Laser beam switched on
b. Battery charge
c. Hold function
d. Measured value display
e. Max. value during the measurement / Emission coefficient
f. Display lighting
g. Unit of measurement °C
h. Set emission coefficient
i. ON / Measure
Instruction
Continuous measurement / Hold
For continuous measurement activate the laser (see figure) and keep the button pressed.
Release the button as soon as the laser circle pinpoints the measurement location. The measured value is held.
Laser circle
The laser circle is a targeting aid to sight the location for the infrared measurement. Temperature measurement is only performed on the surface within the laser circle. Please ensure that the space between the instrument and surface to be measured is free of disturbances (steam, gas, contamination, glass).
Laser output
MAX display
The MAX display determines the maximum measured value within the context of a continuous measurement (keep trigger button pressed). As soon as you release the trigger button and press it again to start a new measurement, the MAX value will be reset and the instrument will start the process of recording the maximum measured value all over again.
Setting the emission coefficient
A built-in sensor head detects the material/surface-specific infrared rays emitted by every object. The level of these emissions is determined by the material‘s emission coefficient (0.01 to 1.00). After switching on for the first time, the device is preset to an emissivity coefficient of 0.95, which is suitable for most organic materials as well as plastics, ceramics, wood, rubber and stone. For materials with different emissivity coefficients, please refer to the table under point 6.
Unknown emission coefficient:
Apply masking tape or black matt paint to the surface of the area whose temperature you wish to measure. Wait until the tape/paint has heated up. The temperature of the surface can then be measured with an emission coefficient of 0.95.
Button pressed briefly: Value +0.01
Keep button pressed:
Value runs through 0.01 … 1.00
The emissivity coefficient last selected is set after the device is switched on. Check the emissivity ! coefficient setting before each measurement.
Table of emission coefficients
Metals
Alloy A3003
Oxidised
Roughened| 0.3
0.1- 0.3
---|---
Aluminium Oxidised| 0.2 -OA
0.04- 0.06
Polished
Brass
Polished
Oxidised| 0.3
0.5
Copper
Oxidised
Elect. terminal strips| 0.4
0.6
– 0.8
Haynes
Metal alloy| 0.3
– 0.8
Inconel
Oxidised
Sandblasted
Electropolished| 0.7
0.3
– 0.95
– 0.6
0.15
Iron
Oxidised
With rust
With red rust| 0.5-0.9 0.5-0.7 0.61 -0.85
---|---
Iron, cast
Oxidised
Non-oxidised
Molten mass| 0.6-0.95
0.2
0.2 -0.3
Iron, forged
Matt
| 0.9
Lead
Rough
Oxidised
| 0.4
0.2 -0.6
Molybdenum
Oxidised
| 0.2 -0.6
Nickel
Oxidised
| 0.2 -0.6
Platinum Black| 0.9
---|---
Steel
Cold rolled
Ground plate
Polished plate
Alloy (8% nickel, 18% chromium)
Galvanised
Oxidised
Heavily oxidised
Freshly rolled
Rough, flat surface
Rusty, red
Sheet, nickel plated
Sheet, rolled| 0.7 – 0.9
0.4 -0.6
0.1
0.35
0.28
0.80
0.88
0.24
0.95- 0.98
0.69
0.11
0.56
Zinc
Oxidised| 0.1
Nonmetals
Asbestos | 0.93 |
---|---|
Asphalt | 0.95 |
Basalt | 0.70 |
Brick, red | 0.93 |
Carborundum | 0.90 |
Ceramics | 0.95 |
China
Brilliant white With glaze
| 0.7-0.75 0.92
Clay| 0.95
Coal Non-oxidised| 0.8-0.9
Concrete, plaster, mortar| 0.93
Cotton| 0.77
Earthenware, matt| 0.93
Fabric| 0.95
Glass| 0.85-0.94
Graphite| 0.7 -0.8
---|---
Gravel| 0.95
Gypsum| 0.8 -0.95
Heat sink Black, anodized| 0.98
Human skin| 0.98
Ice
Clear With heavy frost| 0.97
0.98
Lime| 0.3 -0.4
Lime maim brick| 0.95
Limestone| 0.98
Marble
Black, dull finish Greyish, polished| 0.94
0.93
Masonry| 0.93
Paint
Black, matt Heat-resistant White| 0.96 -0.98 0.92
0.85 -0.95
Paper
All colours
| 0.95-0.97
---|---
Plastic
Translucent PE, P, PVC| 0.95
0.94
Quartz glass| 0.93
Rubber
Hard
Soft, grey| 0.94- 0.95 0.89
Snow| 0.80
Soil| 0.9 – 0.98
Tar| 0.79-0.84
Tar paper| 0.91- 0.93
Transformer paint| 0.94
Wallpaper, light-coloured| 0.88- 0.90
Water| 0.93
Wood
Untreated
Beech, planed| 0.8 -0.95 0.94
Technical data
Technical revisions reserved. 01.15
Measurement range | -38°C … 600°C |
---|---|
Accuracy | ± 2°C + 0,05°C / degree (-38°C … 0°C) ± 2°C (0°C … 600°C) or ± 2% |
whichever value is greater
Optic| 12:1 (distance : measured spot)
Resolution| 0.2°C
Emission coefficient| 0.01 … 1.00
Laser wavelength| 650 nm
Laser type| Laser class 2, < 1 mW
Operating temperature| 0°C … 50°C
Storage temperature| -10°C … 60°C
Relative humidity| 20%rH … 80%rH, no condensation
Power supply| 2 x 1.5V alkaline batteries (type AAA)
Dimensions (W x H x D)| 46 x 158 x 125 mm
Weight (incl. batteries)| 210 g
EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: www.laserliner.com/info
SERVICE
Umarex GmbH & Co KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
laserliner@umarex.de
Umarex GmbH & Co KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>