Laserliner 035 00 SensoPilot Pro Laser Machine Receiver Instruction Manual
- June 5, 2024
- Laserliner
Table of Contents
- SensoPilot Pro
- Remote display for SensoPilot Pro
- General safety instructions
- Safety instructions
- Danger – powerful magnetic fields
- Information on maintenance and care
- Operation of SensoPilot Pro
- Operation of remote display
- Technical data
- EU directives and disposal
- SERVICE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Laserliner 035 00 SensoPilot Pro Laser Machine Receiver Instruction Manual
SensoPilot Pro
Laser receiver for steering construction machines. In combination with a rotation laser, the SensoPilot is used for continuous level/height monitoring. Through four 25 cm laser receiver units, the laser beam can be received in a radius of 360°. The laser level is indicated by large, very easily visible LEDs. Range: 200 m. Highly robust waterproof and dustproof housing with powerful magnets for fixing to the machine.
Remote display for SensoPilot Pro
The remote display allows the reference height to be viewed direct from the driver‘s cab of the construction machine. It therefore ideally supplements the SensoPilot laser receiver. Highly robust design with mounting base and waterproof and dustproof housing.
General safety instructions
- The device must only be used in accordance with its intended purpose and within the scope of the specifications.
- The measuring tools and accessories are not toys. Keep out of reach of children.
- The structure of the device must not be modified in any way.
- Avoid strong vibrations and extreme temperature fluctuations.
- The device must no longer be used if one or more of its functions fail or the battery charge is weak.
- Use the power supply/charger unit only in closed rooms; do not expose to moisture or rain otherwise risk of electric shock.
- Charge the device‘s battery completely prior to use.
- Please only use the power pack/charger supplied. Using any other power pack/charger will invalidate the warranty.
- Charging is completed after 15 hours.
- The battery can also be charged while using the device.
- Disconnect the power pack from the power supply when the device is not in use.
- To avoid the risk of fire, electric shock or personal injury never use extension cables as well as accessories not approved by the manufacturer in connection with the battery charger.
Safety instructions
Dealing with electromagnetic radiation
- The measuring device complies with electromagnetic compatibility regulations and limit values in accordance with EMC-Directive 2014/30/EU.
- Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
-
Cover for charger socket
-
Charger socket
-
LED charge display
-
Socket for SensoPilot – remote display connection cable OR 12/24V battery cable
-
Laser beam receiver fields
-
LED laser height display (green)
-
LED laser height display (red)
-
LED laser height display (red)
Remote display for SensoPilot Pro
-
Extrem powerful Magnets for fixing to building machine
-
ON / OFF switch Precision selection 11 LED laser height display
-
Socket for SensoPilot – remote display connection cable
-
Socket for 12/24V battery cable
-
Fixing bracket
-
Securing screw for fixing bracket
Danger – powerful magnetic fields
Powerful magnetic fields can adversely affect persons with active medical implants (e.g. pacemaker) as well as electro mechanical devices (e.g. magnetic cards, mechanical clocks, precision mechanics, hard disks). With regard to the effect of powerful magnetic fields on persons, the applicable national stipulations and regulations must be complied with such as BGV B11 §14 „electromagnetic fields“ (occupational health and safety – electromagnetic fields) in the Federal Republic of Germany. To avoid interference/disruption, always keep the implant or device a safe distance of at least 30 cm away from the magnet
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.
Operation of SensoPilot Pro
Power supply
- Before using the SensoPilot, ensure the batteries are fully charged.
- If LEDs 6 / 7 / 8 blink from inside to outside, the batteries need recharging. To do so, remove the cover of the charger socket (1) and connect the charger. Recharging takes approx. 15 hours.
- Alternatively, the SensoPilot can be operated and be recharged at the same time from the battery of the construction machine via the 12/24V battery cable. To do this, plug the battery cable into the socket (4).
- When no laser beam is being received, the SensoPilot switches itself off automatically.
Fixing the SensoPilot Pro
The powerful magnets (9) allow the SensoPilot to be fixed directly on the construction machine. Take care that the contact surfaces are clean and level so as to ensure that the magnets have a firm and reliable hold.
The extremely powerful magnets pose a risk of crush injuries.
Putting the SensoPilot into operation
Press the ON / OFF switch once; all the LEDs will flash briefly. The SensoPilot is now ready for operation. The large oblong receiver fields (5) recognise the laser beam, and the LEDs (6, 7, 8) indicate when the reference height is reached.
- Upper LEDs blinking: Move the SensoPilot upwards.
- Middle LED (6): The SensoPilot is at reference height.
- Lower LEDs blinking: Move the SensoPilot downwards.
Precision select
Two levels of precision (HIGH and LOW) can be selected. Changeover between the precision levels is done using the On / OFF switch (10).
- HIGH: The inner LEDs (7) blink 3 times.
- LOW: The outer LEDs (8) blink 3 times.
Switching off the SensoPilot
Press the ON / OFF switch (10) for about 3 seconds.
Rotation laser
For generating a laser reference height, automatic rotation lasers with a high maximum rotation speed are best
The SensoPilot Pro cannot be used together with line lasers
Operation of remote display
Power supply
- In the case of battery operation, power is supplied from the SensoPilot.
- For operation from the battery of the construction machine, connect the remote display (13) using the 12/24V battery cable, ensuring that RED is connected to the positive battery pole (+) and BLACK to earth (engine block). The SensoPilot is then also supplied with power via the connection cable – see illustration below.
Use of the remote display
The remote display allows laser reception of the SensoPilot to be monitored when this cannot be seen from the cab of the construction machine. In this case, connect the remote display (12) to the SensoPilot (4) using the connection cable and install the remote display in the operator‘s cab.
Technical data
- Laser reception range 200 m
- Precision HIGH ± 2 mm – ± 5 mm
- Precision LOW ± 5 mm – ± 15 mm
- Battery / Charger 7,2 V NiMh / 2500 mA
- Battery operating time / Charging time approx. 40 hours / approx. 15 hours
- Working temperature -20°C … 50°C
- Dimensions 390 x 170 x 85 mm
- Weight of SensoPilot / remote display 3,4 kg / 1,1 kg
EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at:
http://laserliner.com/info?an=sesopipr
SERVICE
Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
info@laserliner.com
Umarex GmbH & Co. KG
Donnerfeld 2
59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>