Laserliner 036 650 Superplane-Laser 3D Pro Line Laser Instruction Manual

June 5, 2024
Laserliner

Laserliner 036 650 Superplane-Laser 3D Pro Line Laser

| Completely read through the operating instructions, the “Warranty and Additional Information” booklet as well as the latest information under the internet link at the end of these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.
---|---

Function / Application

Three-dimensional laser with three 360° laser circles.
– The slope-mode feature is an extra that permits gradients to be laid out.
– Straight forward plumb function using laser crosses
– Optimised for work close to the ceiling
– Out-Of-Level: is indicated by optical signals when the unit is outside its self-levelling range.
– With the magnetic clamp and wall bracket the device can be used as a standalone unit, in a combination as well as in horizontal and vertical position.
– Automatic levelling range 2.5°, Accuracy 0.2 mm / m

General safety instructions

The device must only be used in accordance with its intendedpurpose and within the scope of the specifications.
­ The measuring tools and accessories are not toys. Keep out of reach of children.
­ Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
­ Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.

Safety instructions

Using class 2 lasers

– Attention: Do not look into the direct or reflected beam.
– Do not point the laser beam towards persons.
– If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
– Under no circumstances should optical instruments (magnifying glass, microscope, binoculars) be used to look at the laser beam or reflections.
– Do not use the laser at eye level (1.40 … 1.90 m)
– Reflective, specular or shiny surfaces must be covered whilst laser devices are in operation.
– In public areas shield off the laser beam with barriers and partitions wherever possible and identify the laser area with warning signs.

Safety instructions

Dealing with electromagnetic radiation
– The measuring device complies with electromagnetic compatibility regulations and limits in accordance with the EMC Directive 2014/30/EU.
– Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply. There is a possibility of a dangerous impact on – or interference with – electronic devices.

| When transporting always switch off all lasers, secure the pendulum ! and set the slide switch to„ OFF“!
---|---

Special product features

| Automatic alignment of the device with a magnetically dampened pendulum system. The device is brought into initial position and aligns itself autonomously.
---|---
| Transport LOCK: The device is protected with a pendelum lock during transport.
| Devices with PowerBright technology have special highperformance diodes to produce super bright laser lines. These remain visible over longer distances, in bright ambient light and on dark surfaces.
| RX-/GRX-READY technology enables line lasers to be used even in unfavourable light conditions.The laser lines pulsate at a high frequency and this can be picked up by special laser receiversover long distances.

Green laser technology (SuperPlane-Laser 3G Pro)

| Devices with PowerGreen++ technology have extremely bright green laser diodes of the highest performance class that allow very good visibility of laser lines at great distances, on dark surfaces and in bright ambient lighting conditions.
---|---
| Approx. 6 times brighter than a typical red laser with 630 – 660 nm

Number and direction of the lasers

H = horizontal laser / V = vertical laser / S = Slopefunction

Product Descriptions

  1. Laser emitting window

  2. Slide switch
    a ON
    b OFF / Slope mode / Transport lock

  3. Rechargeable battery compartment (bottom)

  4. 1/4”/5/8“-tripod threads (bottom)

  5. Connecting socket for mains adapter (12V/2000mA, no charging function)

  6. LED Hand receiver mode

  7. Hand receiver mode

  8. LED Status indicator / Battery charge

  9. Laser line selection button

Use of lithium-ion rechargeable battery

Fully charge the battery before using for the first time. To charge the battery, place it in the supplied battery charger. Ensure the battery is inserted the right way round. When the rechargeable battery is being charged, the LED on the charger lights up red. When the LED changes to green, charging is complete. The LED (8) flashing indicates that the battery charge level is low. The laser lines automatically switch off when the battery charge is very low. In that case, recharge the battery.

| The battery may only be charged with the battery charger provided and used only in this laser device. Any other use may cause injury or fire.
---|---
| Make sure there are no conductive objects in the vicinity of the battery contacts. Short-circuiting of these contacts can cause burn injuries or fire.
| Do not open the rechargeable battery. This could cause short-circuits

Power supply

To insert the lithium-ion rechargeable battery
Open the battery compartment and insert the lithium-ion battery as illustrated.

Operation with power supply unit
The device can be used with the supplied power supply unit.

| The battery is not charged when connected to the power supply.
---|---

Horizontal and vertical levelling

Release the transport restraint, set slide switch (2) to ,,ON”. The horizontal laser line appears. The laser lines can be switched individually with the selection button.

| The transport restraint must be released for horizontal and vertical levelling. The laser lines flash when the device is outside the automatic levelling range of 2.5°. Position the device such that it is within the levelling range.
---|---

Slope mode

Do not release the transport restraint, set slide switch (2) to ,,OFF”. Select the laser with the selector button (9). Sloping planes and tilts can now be measured. In this mode, the laser lines no longer align automatically. This is signalised by the laser lines flashing.

Hand receiver mode

Optional: Working with the laser receiver RX/GRX
Use an RX/GRX laser receiver (optional) to carry out levelling at great distances or when the laser lines are no longer visible. To work with a laser receiver, switch the line laser to hand-held receiver mode by keeping button 7 (handheld receiver mode on / off) pressed. The laser lines will now pulsate with high frequency, making the laser lines darker. The laser receiver can detect these pulsating laser lines.

| Observe the laser receiver‘s operating instructions for line lasers.
---|---
| Due to the special optics required to generate a continuous 360° laser line, the underlying technology may cause differences in brightness in different areas of the line. This may lead to different ranges in hand receiver mode.

**Preparing the calibration check

**

It is possible for you to check the calibration of the laser. To do this, position the device midway between 2 walls, which must be at least 5 metres apart.Switch the device on (Laser cross ON). The best calibration results are achieved if the device is mounted on a tripod.

  1. Mark point A1 on the wall.

  2. Turn the device through 180° and mark point A2. You now have a horizontal reference between points A1 and A2.

    Performing the calibration check

  3. Position the device as near as possible to the wall at the height of point A1.

  4. Turn the device through 180° and mark point A3. The difference between points A2 and A3 is the tolerance.

| When A2 and A3 are more than 0.2 mm / m apart, an adjustment is necessary. Contact your authorised dealer or else the UMAREXLASERLINER Service Department.
---|---

Checking the vertical line

Position the device about 5 m from a wall. Fix a plumb bob with a line of 2.5 m length on the wall, making sure that the bob can swing freely. Switch on the device and align the vertical laser to the plumb line. The precision is within the specified tolerance if the deviation between the laser line and the plumb lineis not greater than ± 1 mm.

Checking the horizontal line

Position the device about 5 m from a wall and switch on the cross laser. Mark point B on the wall. Turn the laser cross approx. 2.5 m to the right and mark point C. Check whether the horizontal line from point C is level with point B to within ± 1 mm. Repeat the process by turning the laser to the left.

| Regularly check the calibration before use, after transport and after ! extended periods of storage.
---|---

Calibration

The meter needs to be calibrated and tested on a regular basis to ensure it produces accurate measurement results. We recommend carrying out calibration once a year.

Information on maintenance and care

Clean all components with a damp cloth and do not use cleaning agents, scouring agents and solvents. Remove the battery(ies) before storing for longer periods. Store the device in a clean and dry place.

Technical data (Subject to technical changes without notice. 21W03)

EU directives and disposal
This device complies with all necessary standards for the free movement of goods within the EU.
This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical and electronic equipment.
Further safety and supplementary notices at: http://laserliner.com/info?an=AFN

SERVICE

Umarex GmbH & Co. KG
– Laserliner –
Möhnestraße 149, 59755 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: +49 2932 638-333
[email protected]

Umarex GmbH & Co. KG
Donnerfeld 2 59757 Arnsberg, Germany
Tel.: +49 2932 638-300, Fax: -333
www.laserliner.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals