Laserliner 080 855 Laser Range Master T7 Laser Range Finder Owner’s Manual

June 5, 2024
Laserliner

Laserliner 080 855 Laser Range Master T7 Laser Range Finder

Completely read through the operating instructions, the „Warranty and Additional Information“ booklet as well as the latest information under the internet link at the end of] these instructions. Follow the instructions they contain. This document must be kept in a safe place and if the laser device is passed on, this document must be passed on with it.

Compact laser distance meter for measuring length, area, and volume indoors.

OVERVIEW

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-1

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-2

General safety instructions

  • The device must only be used in accordance with its intended purpose and within the scope of the specifications.
  • The measuring tools and accessories are not toys. Keep out of reach of children.
  • Modifications or changes to the device are not permitted, this will otherwise invalidate the approval and safety specifications.
  • Do not expose the device to mechanical stress, extreme temperatures, moisture or significant vibration.
  • The device must no longer be used if one or more of its functions fail or the battery charge is weak.
  • Please ensure compliance with the safety regulations set out by local and national authorities with regard to the correct and proper use of the device.

Safety instructions

Using class 2 lasers

  • Laser radiation!
  • Do not stare into the beam!
  • Class 2 laser
  • < 1 mW · 635 nm
  • EN 60825-1:2014

Attention: Do not look into the direct or reflected beam.

  • Do not point the laser beam towards persons.
  • If a person‘s eyes are exposed to class 2 laser radiation, they should shut their eyes and immediately move away from the beam.
  • Tampering with (making changes to) the laser device is not permitted.
  • Under no circumstances should optical instruments (magnifying glass, microscope, binoculars)

Safety instructions

Dealing with electromagnetic radiation

  • The measuring device complies with electromagnetic compatibility regulations and limits values in accordance with EMC-Directive 2014/30/EU.
  • Local operating restrictions – for example, in hospitals, aircraft, petrol stations or in the vicinity of people with pacemakers – may apply.
  • Electronic devices can potentially cause hazards or interference or be subject to hazards or interference.
  • The measuring accuracy may be affected when working close to high voltages or high electromagnetic alternating fields.

DISPLAY

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-3

  • Measured value memory
  • Unit of measure m / ft / inch /
  • Measurement point (reference) front / thread / rear
  • Set measuring level
  • Battery symbol
  • Set measuring function
  • 1st / 2nd and 3rd length measurement
  • 4th length measurement
  • Measuring functions
  • Addition function
  • Subtraction function

KEYPAD

  1. Measure min/max continuous measurement
  2. ON / OFF.

Switch on, measure and switch offLaserliner-080-855-Laser-Range-Master-T7
-Laser-Range-Finder-FIG-5

Change unit of measure

  • m / ft / inch /

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-6

Change measurement point (reference)

  • front / thread / rearLaserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-FIG-7

Change measurement function

  • length / area / volume / pythagoras 1 / pythagoras 2 / pythagoras 3Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-FIG-8

Length measurement

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-9

min/max continuous measurement

  • The LC display shows the max value, the min value and the current value.Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-FIG-10

In the area measurement, volume measurement, and Pythagoras 1 to 3 functions, the laser will switch off if left idle for a short time and must be switched on again by pressing button 1 in order to continue the measurement.

Area measurement

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-11


Volume measurement


Pythagoras function 1

Pythagoras function 2


Pythagoras function 3


Addition and subtraction of lengths

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-16

  1. Length measurement
  2. Addition or subtraction selection
  3. Add length measurement

Area calculation

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-17

  1. Area measurement
  2. Addition or subtraction selection
  3. Add area measurement

Volume calculation

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-18


  • Volume measurement
    1. Addition or subtraction selection
  • Add volume measurement

Memory function:
The device has 30 storage locations

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-19


Exit memory

or

Error codes

  • 204 Calculation error
  • 208 Excess current (please contact your retailer)
  • 220 Replace the battery
  • 252 Temperature is too high
  • 253 Temperature is too low
  • 255 Received signal too weak or measuring time too long
  • 256 Received signal too strong
  • 251 Outside the measuring range
  • 500 Hardware fault (If the symbol stays on after switching the device off and on, please contact your retailer.)

Important notices

  • The laser points to the location that will be measured.
  • No objects may get into the laser‘s line of measurement.
  • The device compensates the measurement for different room temperatures. Therefore allow the device a brief adaptation period when changing locations with large temperature differences.
  • The device is only conditionally useable in outdoor areas and cannot be used in strong sunlight.
  • The measurement results of outdoor measurements may be influenced or falsified by rain, fog and snow.
  • In unfavourable conditions, e.g. with poorly reflecting surfaces, the maximum deviation may be greater than 3 mm.
  • Carpeting, upholstery or curtains will not reflect the laser optimally. Measure to flat surfaces.
  • Measurements made through glass (window panes) can falsify measurement results.
  • An energy-saving function switches the device off automatically.
  • Clean with a soft cloth. Water may not be allowed to penetrate the housing.

Technical Data (Subject to technical changes without notice. 17W51)

Inside measurement range| 0,2 m – 70 m
Precision (typical)*| ± 0,2 mm / m
Laser class| 2 < 1 mW
Laser wavelength| 635 nm
Power supply| 3 x AAA 1.5 Volt batteries
Dimensions (W x H x D)| 49 x 115 x 26 mm
Weight (incl. batteries)| 145 g
Automatic switch-off| 30 sec laser / 3 min device

Operating conditions

| -10°C…40°C, Max. humidity 20…85% rH, no condensation, Max. working altitude 2000 m above sea level
Storage conditions| -20°C…70°C,

Max. humidity 80% rH

measuring distance up to 10 m with strongly reflective target surface and at room temperature. The measurement deviation may increase by ± 0.2 mm/m for greater distances and under unfavourable measuring conditions such as strong sunlight or weakly reflective target surfaces

EU directives and disposal

This device complies with all necessary standards for the free movement of goods within the EU. This product is an electric device and must be collected separately for disposal according to the European Directive on waste electrical andmelectronic equipment.

Further safety and supplementary notices at: http://laserliner.com/info?an=lrmt7

Laserliner-080-855-Laser-Range-Master-T7-Laser-Range-Finder-
FIG-22

SERVICE

Umarex GmbH & Co. KG

  • Laserliner
  • Möhnestraße 149, 59755 Arnsberg, Germany
  • Tel: +49 2932 638-300, Fax: +49 2932 638-333
  • info@laserliner.de

Umarex GmbH & Co. KG

  • Donnerfeld 2
  • 59757 Arnsberg, Germany
  • Tel: +49 2932 638-300, Fax: -333
  • www.laserliner.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Laserliner User Manuals

Related Manuals