CONCEPT OPO 5342N Vapor island absorber Instruction Manual
- June 5, 2024
- concept
Table of Contents
- CONCEPT OPO 5342N Vapor island absorber
- ACKNOWLEDGMENT
- Technical parameters
- IMPORTANT NOTICES
- Installation
- Normal operation
- PRODUCT DESCRIPTION
- DESCRIPTION OF THE CONTROL PANEL
- OPERATING INSTRUCTIONS
- CLEANING AND MAINTENANCE
- UNIT INSTALLATION
- TROUBLESHOOTING
- ENVIRONMENTAL PROTECTION
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CONCEPT OPO 5342N Vapor island absorber
ACKNOWLEDGMENT
Thank you for purchasing a Concept product. We hope you will be satisfied with our product throughout its service life. Please study the entire Operating Manual carefully before you start using the product. Keep the manual in a safe place for future reference. Make sure other people using the product are familiar with these instructions.
Technical parameters
Technical parameters
Voltage| 230 V ~ 50 Hz
Power input| 287 W
Version| Island
ASSEMBLY| Ceiling
Width| 405 mm
Depth| 305 mm
Height| 865 – 1,120 mm
Output piping diameter| 150 mm
Number of fans| 1
Number of fan power levels| 4
Capacity| Maximum 900 m3/h
Number of fat filters| 1
Mode| Airing or re-circulation
Odor sensor/automatic mode| Yes/Yes
Lighting| 4x 3 W LED
Weight| 23 kg
Noise level, airing/re-circulation| < 49/51 dB(A)
The manufacturer reserves the right to perform technical modifications and design changes without prior notice
IMPORTANT NOTICES
Delivery
- Check the package and unit immediately after delivery for any damage that may have occurred during shipping.
- If the unit is damaged, do not operate it. Contact the supplier as soon as possible.
- Remove all the covering and marketing materials from the unit before the first use.
- Dispose of the packaging material properly.
Installation
- The unit is designed to be mounted on the ceiling.
- Follow the instructions for the appliance connection and installation.
- The unit has to be disconnected from the power socket during installation.
- Before connecting the appliance, ensure that your local connection is earthed and compliant with all applicable regulations.
- Make sure the mains voltage and current protection correspond to the values on the rating plate. Use earthed wall outlets only.
- After installation of the unit, the plug or circuit breaker shall be freely accessible.
- Only an authorized technician may install and connect your appliance.
- Improper connection and/or incompetent installation may result in injury or death.
- The manufacturer takes no responsibility for any damage incurred due to improper installation or use.
Normal operation
- Use the unit only as described in this operating manual.
- Use the unit only in a household, solely for the purpose of absorbing vapor created during cooking, or re-circulation and absorption of odors created during cooking.
- Install the unit at least 650 mm above an electric stove (or hotplate), and 700 mm at minimum above a gas stove (or gas hotplate).
- Never operate the appliance with wet hands.
- In case of any failure and before maintenance and cleaning, turn off the product and disconnect the plug from the mains outlet, or switch off the circuit breaker.
- Never pull the cord to disconnect the plug from the wall outlet; hold the plug instead.
- Check the appliance and power cord for damage regularly. Never switch on a damaged appliance.
- Do not immerse the power cord, plug, or appliance in water or any other liquid.
- Make sure that all controls are in the OFF position when the appliance is not in use.
- Do not handle open fire under the unit (e.g. flaming)! If you remove a cooking vessel from a gas stove, turn down the flame to the minimum, or turn it off!
- Make sure the diameter of the burner of the gas stove or gas hotplate corresponds to the cookware used. When using smaller than recommended vessels, the flames could touch the sides, and plastic handles could be scorched – risk of fire!
- When you deep-fry or fry food, keep it under continuous supervision. When oil is overheated, there is a risk of fire!
- Keep the intervals for the replacement and cleaning of the filters (every 2 months at minimum). If these instructions are not followed, there is a risk of fire due to fat sediments in the filters!
- For the ventilation ducts, all the applicable standards and regulations shall be observed.
- The diameter of duct pipeline for the airing mode should be approximately the same as the diameter of the output pipe of the absorber.
- The air shall not be ventilated through a chimney used for combustion gases, or in a shaft used for airing rooms where combustion chambers are installed.
- During operation in airing mode a sufficient opening for inlet air shall be made; its size shall be approximately the same as or bigger than that of the hole for ventilated air.
- During simultaneous operation of the unit in airing mode and the stove, the underpressure in the room shall not exceed 4 Pa (0.04 mbar).
- Use manufacturer-recommended accessories only.
Children in the household
- The appliance is not intended for and should not be accessible to children or persons with reduced capabilities.
- The appliance is not intended for use by persons with reduced physical, sensory or mental capabilities or lack of knowledge, unless under the supervision of an acquainted person responsible for their safety.
- Take extra care when using the unit near children.
- Do not use the appliance as a toy.
PRODUCT DESCRIPTION
- Body of the unit
- Upper chimney cover
- Ceiling holder with fan
Accessories
- Backflow valve
DESCRIPTION OF THE CONTROL PANEL
- Fan power level setting buttons
- Display of the set power level, or time of delayed switching off
- Delayed OFF timer setting button
- Lighting ON/OFF button
OPERATING INSTRUCTIONS
Before first use
Prior to the start of use of a new unit, wipe it with a wet and then a dry
cloth.
Airing mode
In this mode the vapors are ventilated through the output pipe into the shaft
and out of the room. If there are carbon filters installed in the unit, remove
them (see the Cleaning and Maintenance paragraph).
- Select the required fan power level by pressing the „+“ and „-“ symbols (1 – 4).
- After use, switch the unit off by setting the fan power level to „0“. Note: This appliance is equipped with boost function. When the device is set to the highest (intensive) speed
- speed after 5 minutes of operation
- it will automatically decrease to
Re-circulation mode
If you have no possibility to ventilate the air out of the room, the re- circulation mode can be selected. In this mode the vapors are filtered through metal and carbon filters. Active carbon in these filters absorbs smells, and the clean air flows back to the room through holes in the upper chimney cover. For this mode, it is necessary to buy and assemble the corresponding carbon filters (see the Cleaning and Maintenance paragraph).
- Select the required fan power level by pressing the „+“ and „-“ symbols (1 – 4).
- After use, switch the unit off by setting the fan power level to „0“. Note: This appliance is equipped with boost function. When the device is set to the highest (intensive) speed
- speed after 5 minutes of operation
- it will automatically decrease to
Switching the lighting on and off
Press the button to turn on the light. Switch the light off by repeatedly pressing the symbol. The lighting direction can be adjusted by tilting the lights.
Delayed OFF function
- Select the required fan power level (1 – 4).
- Press the symbol to activate the delayed off function. A dot symbol will blink on the display.
- Set the required delayed off time by repeatedly pressing the,-“and,+” symbols in the range of 10-90 minutes. Tens of minutes will be displayed, i.e. 1 = 10 minutes, 2 = 20 minutes etc. Confirm by pressing the symbol (the fan power level will be displayed, and the dot symbol will blink). Note: If you don’t confirm the delayed off settings within 20 seconds, the settings will be erased, and the delayed off function will be deactivated.
- The unit will switch off automatically after the preset time runs out. Note: If you press the symbol during the countdown, or switch off the fan manually before the time runs out, the delayed off function will be deactivated.
This function enables the automatic
The unit is equipped with an odor sensor that detects an increased volume of odors in the air. This function enables the automatic regulation of fan power depending on the volume of odors in the air. After connecting to electric power, the fan shall not be switched on for about 5 minutes, so that the sensor can be calibrated.The function is activated by pressing the „–“ symbol for a longer time. „A“ will be displayed. To deactivate the function, press the „–“ symbol for a longer time.
Filter replacement signal function
This function is only indicative; it reminds you when the filters should be
cleaned or replaced under standard use. The function counts hours of
operation, i.e. the unit dooes not detect whether you have already performed
the replacement or not; it just reminds you that a check-up, cleaning or
replacement should be carried out. F”-signal to clean the fat filters will be
displayed after 100 hours of operation. C”-signal to replace the carbon
filters will be displayed after 220 hours of operation. You may reset the
counter by pressing the symbol for 10 seconds; the display will go off.
CLEANING AND MAINTENANCE
- Before any maintenance and cleaning, disconnect the power cord from the mains or switch off the circuit breaker of the mains outlet of the unit.
- Do not immerse the power cord, plug, or appliance in water or any other liquid.
- Set all controls in the OFF position.
- Clean the outer surface of the unit with a wet cloth, or use a neutral detergent.
- Do not use coarse sponges, abrasive cleaners, solvents or aggressive detergents.
- Do not use an autoclave to clean the unit!
CLEANING AND REPLACING THE FILTERS
- Metal fat filter Under normal use, the metal fat filter should be cleaned every 2 months. In case of more frequent frying or deep frying, shorten the interval. Do not use the unit without a properly mounted metal fat filter!
- Open the filter casing (Fig. 1).
- Remove the metal filter (Fig. 2). If a carbon filter is mounted, remove it.
- Leave the metal filter in warm water with a detergent. Clean it with a soft brush, rinse with clean water and let dry.
- Remount the completely dry filter following the reverse steps.
- Close the filter casing.
- Carbon filter (must be purchased) This filter is used only in the re-circulation mode. The filter contains active carbon that a bsorbs the ventilated odors. After a while the active carbon is saturated, and loses its absorption ability. The filter can’t be washed or otherwise cleaned. Under normal use, the carbon filter should be replaced every 2 months. In case of more frequent frying or deep frying, shorten the interval.
- Open the filter casing (Fig. 1).
- Remove the metal filter (Fig. 2), and remove the carbon filter from it.
- Mounta new carbon filter on the metal one (Fig. 3), and put the set back.
- Close the filter casing.
UNIT INSTALLATION
Only authorized personnel can install the power connection!
- Only the customer is responsible for installation in situ. Defects caused by incorrect installation are not covered by the warranty.
- Remove all the covering and marketing materials from the unit before the first use.
- we recommend that you let a specialized company perform the installation.
- The manufacturer bears no responsibility for damage caused to people, animals or objects as a result of incorrect installation.
Follow the installation instructions:
- Mark the center of the hotplate on the ceiling above.
- Drill holes. Fix the ceiling holder using the supplied wall plugs and screws (F) – Fig. 5.
- For the airing mode, mount the backflow valve on the output hole, and connect the output hole of the fan to the hole in the ceiling using a flexible pipe. If necessary, use the adapter (150/120 mm). Note: Flexible pipe and diameter adapter are not supplied.
- Mount the upper chimney cover to the ceiling holder (Fig. 6), and fix it using the screws (F).
- Open the filter casing and remove the fat (or carbon) filter.
- Mount the body unit on the ceiling holder (A), and fix it from the inside using the screws (D), Fig. 7. Keep the minimum required height above the hotplate (650 mm for electric, and 700 mm for gas hotplates, Fig. 4).
- Fix the electronic control plate so that the buttons and display go through the holes in the unit‘s body.
- Open the switch box and connect the control cable. Connect all other possible connectors.
- Mount the fat (or carbon) filter.
- Plug the supply cable into the wall outlet.
Removal
Before removal, disconnect the power cable from wall outlet, and follow the reverse steps to remove individual parts of the unit.
TROUBLESHOOTING
Problem | Cause, solution |
---|---|
The control does not work, or does not work properly. | There was a voltage |
fluctuation or blackout in the network. Disconnect the power source for 10
seconds, then reconnect. The control electronics will be reset.
Low suction performance| Check and clean the metal filters, or replace the
carbon filters.
“A” symbol is displayed.| Automatic fan power regulation function is ON.
“C” symbol is displayed.| Signal for check or replacement of the carbon filter
(re-circulation).
“F” symbol is displayed.| Signal of check or cleaning of the fat filter
(airing mode)
SERVICE
Any extensive maintenance or repair that requires access to the inner parts of the product must be performed by an expert service centre.
ENVIRONMENTAL PROTECTION
- Packaging materials and obsolete appliances should be
- The transport box may be disposed of as sorted
- Polyethylene bags shall be handed over for recycling
Appliance recycling at the end of its service life:
A symbol on the product or its packaging indicates that this product should not go into household waste. It must be taken to the collection point of an electric and electronic equipment recycling facility. By making sure this product is disposed of properly, you will help prevent the negative effects on the environment and human health that would otherwise result from inappropriate disposal of this product. You can learn more about recycling this product from your local authorities, a household waste disposal service or in the shop where you bought this product.
References
- Concept – chytře vymyšleno pro život
- Domena Concept.pl jest na sprzedaż - SklepDomeny.pl
- Online software pre autoservis | servis.sk
- Tech.sk | Všetko o informačných technológiáchTech.sk | Magazín o internete a technológiách
- Concept – chytře vymyšleno pro život
- Concept innowacje w Twoim życiu!
- www.my-concept.sk | vymyslené pre život
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>